不同定位器附着体固位损失定位器附着体固位损失不同固位帽对两种种植固位下颌覆盖义齿的影响

Medhat A. Abdelaziz, A. Fawzy, R. Ghaly, Hossam I. Nassar
{"title":"不同定位器附着体固位损失定位器附着体固位损失不同固位帽对两种种植固位下颌覆盖义齿的影响","authors":"Medhat A. Abdelaziz, A. Fawzy, R. Ghaly, Hossam I. Nassar","doi":"10.54623/fdj.7029","DOIUrl":null,"url":null,"abstract":"Purpose. The objective of this invitro study was to evaluate gradual loss of retention at different time intervals between four different colour coded retentive caps of locator R-TX attachment system through 3000 cycles resembling 3years of attachment usage. Material and Methods. According to prosthetically driven implant placement, two implants were digitally planned and placed by 3D printed surgical stent in an epoxy model. Forty-eight mandibular complete dentures divided into four groups (12 dentures for each group) were constructed to compare Loss of retention between (12 pairs of locator R-TX each retention cap: zero retention, low retention, medium retention and regular retention), each was subjected to insertion and removal cycles resembling 3years of patient usage. Retention values at zero, one, two, three years were recorded using universal testing machine. Results: Locator R-TX medium &low retention showed no statistically significant retention values through three years while locator R-TX regular retention cap showed better retention values at zero, first, second year of use. Conclusion. Locator R-TX attachment systems low, medium, regular retention cap had no statistically significant different retention values at the end of third year of use while there were only statistically significant primary retention values. Clinical Implications. The importance of difference retention caps appears only in the start of over denture treatment until complete patient adaptation to over denture treatment","PeriodicalId":100562,"journal":{"name":"Future Dental Journal","volume":"49 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Retention Loss of Locator Attachment System Different Retention Retention Loss of Locator Attachment System Different Retention Caps for Two Implant Retained Mandibular Overdenture\",\"authors\":\"Medhat A. Abdelaziz, A. Fawzy, R. Ghaly, Hossam I. Nassar\",\"doi\":\"10.54623/fdj.7029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose. The objective of this invitro study was to evaluate gradual loss of retention at different time intervals between four different colour coded retentive caps of locator R-TX attachment system through 3000 cycles resembling 3years of attachment usage. Material and Methods. According to prosthetically driven implant placement, two implants were digitally planned and placed by 3D printed surgical stent in an epoxy model. Forty-eight mandibular complete dentures divided into four groups (12 dentures for each group) were constructed to compare Loss of retention between (12 pairs of locator R-TX each retention cap: zero retention, low retention, medium retention and regular retention), each was subjected to insertion and removal cycles resembling 3years of patient usage. Retention values at zero, one, two, three years were recorded using universal testing machine. Results: Locator R-TX medium &low retention showed no statistically significant retention values through three years while locator R-TX regular retention cap showed better retention values at zero, first, second year of use. Conclusion. Locator R-TX attachment systems low, medium, regular retention cap had no statistically significant different retention values at the end of third year of use while there were only statistically significant primary retention values. Clinical Implications. The importance of difference retention caps appears only in the start of over denture treatment until complete patient adaptation to over denture treatment\",\"PeriodicalId\":100562,\"journal\":{\"name\":\"Future Dental Journal\",\"volume\":\"49 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Future Dental Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.54623/fdj.7029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Future Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54623/fdj.7029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

目的。本体外研究的目的是评估定位器R-TX附着系统的四种不同颜色编码的固位帽在不同时间间隔内逐渐丧失固位,通过类似3年附着使用的3000个周期。材料和方法。根据假体驱动植入物的放置,通过3D打印手术支架将两个植入物数字化规划并放置在环氧树脂模型中。将48个下颌全口义齿分为4组(每组12个义齿),比较两组间的固位损失(每个固位帽12对定位器R-TX:零固位、低固位、中等固位和常规固位),每对义齿均进行类似患者使用3年的插拔周期。使用万能试验机记录零、一、二、三年的保留值。结果:Locator R-TX中、低保留率在使用三年内无统计学意义的保留率值,而Locator R-TX常规保留率在使用零、第一年、第二年均有较好的保留率值。结论。Locator R-TX附着系统低、中、常规固位帽在使用第三年结束时的固位值没有统计学上的显著差异,而只有统计学上显著的主要固位值。临床意义。不同固位帽的重要性只出现在复盖义齿治疗的开始,直到患者完全适应复盖义齿治疗
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Retention Loss of Locator Attachment System Different Retention Retention Loss of Locator Attachment System Different Retention Caps for Two Implant Retained Mandibular Overdenture
Purpose. The objective of this invitro study was to evaluate gradual loss of retention at different time intervals between four different colour coded retentive caps of locator R-TX attachment system through 3000 cycles resembling 3years of attachment usage. Material and Methods. According to prosthetically driven implant placement, two implants were digitally planned and placed by 3D printed surgical stent in an epoxy model. Forty-eight mandibular complete dentures divided into four groups (12 dentures for each group) were constructed to compare Loss of retention between (12 pairs of locator R-TX each retention cap: zero retention, low retention, medium retention and regular retention), each was subjected to insertion and removal cycles resembling 3years of patient usage. Retention values at zero, one, two, three years were recorded using universal testing machine. Results: Locator R-TX medium &low retention showed no statistically significant retention values through three years while locator R-TX regular retention cap showed better retention values at zero, first, second year of use. Conclusion. Locator R-TX attachment systems low, medium, regular retention cap had no statistically significant different retention values at the end of third year of use while there were only statistically significant primary retention values. Clinical Implications. The importance of difference retention caps appears only in the start of over denture treatment until complete patient adaptation to over denture treatment
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信