А. Г. Галка, Алексей Владимирович Костров, М. С. Малышев
{"title":"微卫星电离层等离子浓度共振测定法","authors":"А. Г. Галка, Алексей Владимирович Костров, М. С. Малышев","doi":"10.21883/jtf.2023.01.54066.192-22","DOIUrl":null,"url":null,"abstract":"A method has been developed for diagnostics of the ionospheric plasma density on board a microsatellite using a resonator made on a segment of a two-wire line. The measurements of plasma parameters are based on the amplitude-phase method, which permits extanding the dynamic range of measured values by three orders of magnitude without increasing the resonator length. The paper presents a measurement technique and its experimental testing on a plasma setup under conditions as close as possible to the ionospheric ones","PeriodicalId":24036,"journal":{"name":"Журнал технической физики","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Резонансный метод измерения концентрации ионосферной плазмы на микроспутниках\",\"authors\":\"А. Г. Галка, Алексей Владимирович Костров, М. С. Малышев\",\"doi\":\"10.21883/jtf.2023.01.54066.192-22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method has been developed for diagnostics of the ionospheric plasma density on board a microsatellite using a resonator made on a segment of a two-wire line. The measurements of plasma parameters are based on the amplitude-phase method, which permits extanding the dynamic range of measured values by three orders of magnitude without increasing the resonator length. The paper presents a measurement technique and its experimental testing on a plasma setup under conditions as close as possible to the ionospheric ones\",\"PeriodicalId\":24036,\"journal\":{\"name\":\"Журнал технической физики\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Журнал технической физики\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21883/jtf.2023.01.54066.192-22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Журнал технической физики","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21883/jtf.2023.01.54066.192-22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Резонансный метод измерения концентрации ионосферной плазмы на микроспутниках
A method has been developed for diagnostics of the ionospheric plasma density on board a microsatellite using a resonator made on a segment of a two-wire line. The measurements of plasma parameters are based on the amplitude-phase method, which permits extanding the dynamic range of measured values by three orders of magnitude without increasing the resonator length. The paper presents a measurement technique and its experimental testing on a plasma setup under conditions as close as possible to the ionospheric ones