{"title":"农业回用废水处理节能技术","authors":"Avner Adin, Yigal Kadar","doi":"10.1016/0166-3097(87)90039-3","DOIUrl":null,"url":null,"abstract":"<div><p>Agricultural irrigation is considered to be the most economical way to dispose of municipal wastewater in a sanitary manner in Israel. Due to the location of the irrigated areas, energy expenses for effluent transport cannot be reduced significantly. This paper presents a study which prepares the ground for energy savings at the treatment plants themselves.</p><p>The study consisted of two parts: a survey of different types of treatment plants and a more detailed analysis of an activated-sludge and an aerated lagoons plant. Results show that energy utilization ranges from 140 to 800 W h/m<sup>3</sup> and a properly managed activated-sludge plant can spend less energy than an aerated-lagoon plant. A possible reduction of 20% in plant energy utilization may bring about up to 8% reduction in effluent cost and promote its agricultural application.</p></div>","PeriodicalId":101079,"journal":{"name":"Resources and Conservation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1987-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0166-3097(87)90039-3","citationCount":"4","resultStr":"{\"title\":\"Energy conservation in wastewater treatment for agricultural reuse\",\"authors\":\"Avner Adin, Yigal Kadar\",\"doi\":\"10.1016/0166-3097(87)90039-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Agricultural irrigation is considered to be the most economical way to dispose of municipal wastewater in a sanitary manner in Israel. Due to the location of the irrigated areas, energy expenses for effluent transport cannot be reduced significantly. This paper presents a study which prepares the ground for energy savings at the treatment plants themselves.</p><p>The study consisted of two parts: a survey of different types of treatment plants and a more detailed analysis of an activated-sludge and an aerated lagoons plant. Results show that energy utilization ranges from 140 to 800 W h/m<sup>3</sup> and a properly managed activated-sludge plant can spend less energy than an aerated-lagoon plant. A possible reduction of 20% in plant energy utilization may bring about up to 8% reduction in effluent cost and promote its agricultural application.</p></div>\",\"PeriodicalId\":101079,\"journal\":{\"name\":\"Resources and Conservation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1987-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0166-3097(87)90039-3\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Resources and Conservation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0166309787900393\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Resources and Conservation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0166309787900393","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
摘要
在以色列,农业灌溉被认为是以卫生方式处理城市废水的最经济的方法。由于灌溉区的位置,污水运输的能源费用不能显著减少。本文提出了一项研究,为处理厂本身的节能奠定了基础。该研究包括两部分:对不同类型的处理厂的调查和对活性污泥和曝气泻湖工厂的更详细的分析。结果表明,活性污泥厂的能量利用率在140 ~ 800 W h/m3之间,管理得当的活性污泥厂比曝气泻湖厂能耗更低。工厂能源利用率可能降低20%,可使废水成本降低8%,并促进其农业应用。
Energy conservation in wastewater treatment for agricultural reuse
Agricultural irrigation is considered to be the most economical way to dispose of municipal wastewater in a sanitary manner in Israel. Due to the location of the irrigated areas, energy expenses for effluent transport cannot be reduced significantly. This paper presents a study which prepares the ground for energy savings at the treatment plants themselves.
The study consisted of two parts: a survey of different types of treatment plants and a more detailed analysis of an activated-sludge and an aerated lagoons plant. Results show that energy utilization ranges from 140 to 800 W h/m3 and a properly managed activated-sludge plant can spend less energy than an aerated-lagoon plant. A possible reduction of 20% in plant energy utilization may bring about up to 8% reduction in effluent cost and promote its agricultural application.