中国珠江三角洲闪电活动过程及参数特征

S. Cheng, Jianguo Wang, L. Cai, Yijun Huang, Yutong Xiao, Quanxin Li
{"title":"中国珠江三角洲闪电活动过程及参数特征","authors":"S. Cheng, Jianguo Wang, L. Cai, Yijun Huang, Yutong Xiao, Quanxin Li","doi":"10.1109/ICLPandSIPDA54065.2021.9627436","DOIUrl":null,"url":null,"abstract":"A total lightning activity process lasting 5 hours occurred on August 19, 2014 at pearl river delta in China is analyzed in detail. Based on Foshan Total Lightning Location System, the characteristics and parameters of the total lightning process are proposed. The number of lightning flashes in the thunderstorm reach to 97249, of which intra-cloud(IC) flashes account for 80.4%, cloud-to-ground(CG) flashes 18.8% and narrow bipolar events (NBE) 0.8%. The variation of IC flashes and total lightning are synchronous. More than 96.69% of the height of IC flashes are below 15 km, while 7 km to 10 km is the maximum probability area of IC flashes. The height distribution of NBE is relatively disorganized compared with IC flashes, the variation of which does not show any visible trend.","PeriodicalId":70714,"journal":{"name":"中国防雷","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Total Lightning Activity Process and Parameter Characteristics at Pearl River Delta in China\",\"authors\":\"S. Cheng, Jianguo Wang, L. Cai, Yijun Huang, Yutong Xiao, Quanxin Li\",\"doi\":\"10.1109/ICLPandSIPDA54065.2021.9627436\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A total lightning activity process lasting 5 hours occurred on August 19, 2014 at pearl river delta in China is analyzed in detail. Based on Foshan Total Lightning Location System, the characteristics and parameters of the total lightning process are proposed. The number of lightning flashes in the thunderstorm reach to 97249, of which intra-cloud(IC) flashes account for 80.4%, cloud-to-ground(CG) flashes 18.8% and narrow bipolar events (NBE) 0.8%. The variation of IC flashes and total lightning are synchronous. More than 96.69% of the height of IC flashes are below 15 km, while 7 km to 10 km is the maximum probability area of IC flashes. The height distribution of NBE is relatively disorganized compared with IC flashes, the variation of which does not show any visible trend.\",\"PeriodicalId\":70714,\"journal\":{\"name\":\"中国防雷\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国防雷\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627436\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国防雷","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/ICLPandSIPDA54065.2021.9627436","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

对2014年8月19日发生在中国珠江三角洲的一次持续5小时的闪电活动过程进行了详细分析。基于佛山市总闪电定位系统,提出了总闪电过程的特征和参数。雷暴中共出现97249次闪电,其中云内闪(IC)占80.4%,云对地闪(CG)占18.8%,窄双极闪(NBE)占0.8%。集成电路闪光与总闪电的变化是同步的。超过96.69%的IC闪光高度在15 km以下,而7 ~ 10 km是IC闪光的最大概率区域。与集成电路闪光相比,NBE的高度分布相对混乱,其变化没有明显的趋势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Total Lightning Activity Process and Parameter Characteristics at Pearl River Delta in China
A total lightning activity process lasting 5 hours occurred on August 19, 2014 at pearl river delta in China is analyzed in detail. Based on Foshan Total Lightning Location System, the characteristics and parameters of the total lightning process are proposed. The number of lightning flashes in the thunderstorm reach to 97249, of which intra-cloud(IC) flashes account for 80.4%, cloud-to-ground(CG) flashes 18.8% and narrow bipolar events (NBE) 0.8%. The variation of IC flashes and total lightning are synchronous. More than 96.69% of the height of IC flashes are below 15 km, while 7 km to 10 km is the maximum probability area of IC flashes. The height distribution of NBE is relatively disorganized compared with IC flashes, the variation of which does not show any visible trend.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
57
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信