浆料馏分的氯化物剖面何时及如何校准?

IF 0.7 Q4 CONSTRUCTION & BUILDING TECHNOLOGY
Simon Fjendbo, K. De Weerdt, H. Sørensen, M. Geiker
{"title":"浆料馏分的氯化物剖面何时及如何校准?","authors":"Simon Fjendbo, K. De Weerdt, H. Sørensen, M. Geiker","doi":"10.2478/ncr-2021-0021","DOIUrl":null,"url":null,"abstract":"Abstract Due to stochastic and systematic variations in the paste fraction, data for total chloride content are occasionally calibrated using parallelly measured calcium content as a measure of the actual paste fraction − assuming non-calcareous aggregates and no calcium leaching. Data from concrete exposed at the marine Fehmarn Belt Exposure Site questions the latter assumption. In the outer zone experiencing calcium leaching (ten mm after ten years), errors will be introduced by calcium calibration. To account for the wall effect, calcium profiles from cores taken before exposure might be used to correct for the systematically higher paste fraction at cast surfaces.","PeriodicalId":42762,"journal":{"name":"Nordic Concrete Research","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"When and How Should Chloride Profiles be Calibrated for Paste Fraction?\",\"authors\":\"Simon Fjendbo, K. De Weerdt, H. Sørensen, M. Geiker\",\"doi\":\"10.2478/ncr-2021-0021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Due to stochastic and systematic variations in the paste fraction, data for total chloride content are occasionally calibrated using parallelly measured calcium content as a measure of the actual paste fraction − assuming non-calcareous aggregates and no calcium leaching. Data from concrete exposed at the marine Fehmarn Belt Exposure Site questions the latter assumption. In the outer zone experiencing calcium leaching (ten mm after ten years), errors will be introduced by calcium calibration. To account for the wall effect, calcium profiles from cores taken before exposure might be used to correct for the systematically higher paste fraction at cast surfaces.\",\"PeriodicalId\":42762,\"journal\":{\"name\":\"Nordic Concrete Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nordic Concrete Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/ncr-2021-0021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nordic Concrete Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ncr-2021-0021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

由于膏体分数的随机和系统变化,总氯化物含量的数据有时使用平行测量的钙含量作为实际膏体分数的测量来校准-假设非钙质聚集体和无钙浸出。在海上费尔马恩带暴露地点暴露的混凝土数据对后一种假设提出了质疑。在经历钙浸出的外区(十年后10毫米),将通过钙校准引入误差。为了解释壁效应,在暴露前从岩心中提取的钙剖面可以用来纠正铸造表面的高膏体分数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
When and How Should Chloride Profiles be Calibrated for Paste Fraction?
Abstract Due to stochastic and systematic variations in the paste fraction, data for total chloride content are occasionally calibrated using parallelly measured calcium content as a measure of the actual paste fraction − assuming non-calcareous aggregates and no calcium leaching. Data from concrete exposed at the marine Fehmarn Belt Exposure Site questions the latter assumption. In the outer zone experiencing calcium leaching (ten mm after ten years), errors will be introduced by calcium calibration. To account for the wall effect, calcium profiles from cores taken before exposure might be used to correct for the systematically higher paste fraction at cast surfaces.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nordic Concrete Research
Nordic Concrete Research CONSTRUCTION & BUILDING TECHNOLOGY-
自引率
20.00%
发文量
8
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信