{"title":"基于反馈回路控制电流分析的AMBs控制转子剩余不平衡质量确定","authors":"Tianpeng Fan, Zhe Sun, Xiaoshen Zhang, Xunshi Yan, Jingjing Zhao, Zhengang Shi","doi":"10.1115/ICONE26-81575","DOIUrl":null,"url":null,"abstract":"Active magnetic bearing technology is used more and more for its high performance, such as high speed and frictionless operation. But the rotor vibrates sometimes during operation due to the existence of residual unbalanced mass, which may affect the security of the whole system. In order to determine the distribution of residual unbalanced mass, this paper proposes a method based on frequency response, control current analysis, and image data processing. The theoretical and calculated results show the validity of the method.","PeriodicalId":65607,"journal":{"name":"International Journal of Plant Engineering and Management","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Residual Unbalanced Mass Determination of an AMBs Controlled Rotor Based on Control Current Analysis of the Feedback Loop\",\"authors\":\"Tianpeng Fan, Zhe Sun, Xiaoshen Zhang, Xunshi Yan, Jingjing Zhao, Zhengang Shi\",\"doi\":\"10.1115/ICONE26-81575\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Active magnetic bearing technology is used more and more for its high performance, such as high speed and frictionless operation. But the rotor vibrates sometimes during operation due to the existence of residual unbalanced mass, which may affect the security of the whole system. In order to determine the distribution of residual unbalanced mass, this paper proposes a method based on frequency response, control current analysis, and image data processing. The theoretical and calculated results show the validity of the method.\",\"PeriodicalId\":65607,\"journal\":{\"name\":\"International Journal of Plant Engineering and Management\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Plant Engineering and Management\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.1115/ICONE26-81575\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Plant Engineering and Management","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1115/ICONE26-81575","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Residual Unbalanced Mass Determination of an AMBs Controlled Rotor Based on Control Current Analysis of the Feedback Loop
Active magnetic bearing technology is used more and more for its high performance, such as high speed and frictionless operation. But the rotor vibrates sometimes during operation due to the existence of residual unbalanced mass, which may affect the security of the whole system. In order to determine the distribution of residual unbalanced mass, this paper proposes a method based on frequency response, control current analysis, and image data processing. The theoretical and calculated results show the validity of the method.