R.A. Belakhmima , N. Errahmany , M. Ebn Touhami , H. Larhzil , R. Touir
{"title":"化学镀Cu-P保护剂在摩尔盐酸溶液中的制备及性能研究","authors":"R.A. Belakhmima , N. Errahmany , M. Ebn Touhami , H. Larhzil , R. Touir","doi":"10.1016/j.jaubas.2017.01.001","DOIUrl":null,"url":null,"abstract":"<div><p>A new basic formulation of electroless Cu–P plating using sodium hypophosphite as reducing agent was developed at different concentration of NiSO<sub>4</sub>. So, the effect of temperature solution, pH and immersion time on deposition rate was also investigated. It is found that the deposition rate increases with nickel sulphate concentration and temperature and decreases with immersion time. The cyclic voltammetry study showed that the electroless deposition was controlled by the anodic processes. In addition, the scanning electron microscopy (SEM) observations and energy dispersive X-ray (EDX) analysis were used to characterize Cu–P deposit. Thus, the micrograph showed that coating presents a nodular aspect and is relatively homogeneous. Finally, the corrosion protection of mild steel by this coating in 1.0<!--> <!-->M HCl was studied using electrochemical measurements. It is found that the protection increases with NiSO<sub>4</sub> concentration and reaches 92% at 2<!--> <!-->g<!--> <!-->L<sup>−1</sup>.</p></div>","PeriodicalId":17232,"journal":{"name":"Journal of the Association of Arab Universities for Basic and Applied Sciences","volume":"24 ","pages":"Pages 46-53"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jaubas.2017.01.001","citationCount":"9","resultStr":"{\"title\":\"Preparation and characterization of electroless Cu–P deposition protection for mild steel corrosion in molar hydrochloric solution\",\"authors\":\"R.A. Belakhmima , N. Errahmany , M. Ebn Touhami , H. Larhzil , R. Touir\",\"doi\":\"10.1016/j.jaubas.2017.01.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A new basic formulation of electroless Cu–P plating using sodium hypophosphite as reducing agent was developed at different concentration of NiSO<sub>4</sub>. So, the effect of temperature solution, pH and immersion time on deposition rate was also investigated. It is found that the deposition rate increases with nickel sulphate concentration and temperature and decreases with immersion time. The cyclic voltammetry study showed that the electroless deposition was controlled by the anodic processes. In addition, the scanning electron microscopy (SEM) observations and energy dispersive X-ray (EDX) analysis were used to characterize Cu–P deposit. Thus, the micrograph showed that coating presents a nodular aspect and is relatively homogeneous. Finally, the corrosion protection of mild steel by this coating in 1.0<!--> <!-->M HCl was studied using electrochemical measurements. It is found that the protection increases with NiSO<sub>4</sub> concentration and reaches 92% at 2<!--> <!-->g<!--> <!-->L<sup>−1</sup>.</p></div>\",\"PeriodicalId\":17232,\"journal\":{\"name\":\"Journal of the Association of Arab Universities for Basic and Applied Sciences\",\"volume\":\"24 \",\"pages\":\"Pages 46-53\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.jaubas.2017.01.001\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Association of Arab Universities for Basic and Applied Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1815385217300093\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Association of Arab Universities for Basic and Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1815385217300093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
摘要
以次亚磷酸钠为还原剂,在不同浓度NiSO4的条件下,研制了化学镀Cu-P的新基本配方。因此,研究了温度、溶液、pH和浸泡时间对沉积速率的影响。沉积速率随硫酸镍浓度和温度的升高而升高,随浸液时间的延长而降低。循环伏安法研究表明,化学沉积是由阳极过程控制的。此外,利用扫描电镜(SEM)观察和能量色散x射线(EDX)分析对Cu-P矿床进行了表征。因此,显微照片显示涂层呈现结节状且相对均匀。最后,通过电化学测量研究了该涂层对低碳钢在1.0 M HCl中的防腐效果。结果表明,随着NiSO4浓度的增加,保护作用增强,在2 g L−1时达到92%。
Preparation and characterization of electroless Cu–P deposition protection for mild steel corrosion in molar hydrochloric solution
A new basic formulation of electroless Cu–P plating using sodium hypophosphite as reducing agent was developed at different concentration of NiSO4. So, the effect of temperature solution, pH and immersion time on deposition rate was also investigated. It is found that the deposition rate increases with nickel sulphate concentration and temperature and decreases with immersion time. The cyclic voltammetry study showed that the electroless deposition was controlled by the anodic processes. In addition, the scanning electron microscopy (SEM) observations and energy dispersive X-ray (EDX) analysis were used to characterize Cu–P deposit. Thus, the micrograph showed that coating presents a nodular aspect and is relatively homogeneous. Finally, the corrosion protection of mild steel by this coating in 1.0 M HCl was studied using electrochemical measurements. It is found that the protection increases with NiSO4 concentration and reaches 92% at 2 g L−1.