Afsaneh Mostagim Ahmadabadi, F. Sahbaeiroy, S. Hejazi
{"title":"2019年德黑兰康复医院清洁间歇导尿患者自我效能仪的心理测量","authors":"Afsaneh Mostagim Ahmadabadi, F. Sahbaeiroy, S. Hejazi","doi":"10.52547/iau.31.4.450","DOIUrl":null,"url":null,"abstract":"Background: The incidence of neural bladder is increasing today and these people need catheterization. Intermittent clean urinary catheterization is a low-risk method for the patients. Materials and methods: This was a descriptive methodological and validation research. For content validity, 10 people were selected by purposive method. For face validity, 25 people were chosen by convenience method Aimed at structural validity, gradual method was used from sounding conductors. For the reliability of the questionnaire, 10 people completed the questionnaire. Results: First, a draft was developed and two qualitative and quantitative methods were used for face validity. The effect scores of the items were not less than 1.5. None of the items less than 62% were deleted according to the table. In construct validity, exploratory factor analysis and varimax rotation methods were used and the adequacy of sample size was 0.78 by KMO test, and the results of Bartlett sphericity test were significant (4017/486 p <0.001). 5 items with a share of less than 0.4 were removed and factor analysis was performed again and the number of factors was reduced to four with a variance of 40.136. The results of internal consistency of Cronbach's alpha coefficient of the whole questionnaire with 32 items were equal to 0.862 and 0.859 for women and men respectively. The results of the stability of the verification tools and the result of the ICC test (0.949) showed a good correlation coefficient for each structure. Conclusion: The tools designed in this study are valid and reliable and can be used in various studies.","PeriodicalId":18492,"journal":{"name":"MEDICAL SCIENCES JOURNAL","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Psychometrics of the self-efficacy instrument of clean intermittent urinary catheterization in patients with neural bladder admitted to rehabilitation hospitals in Tehran in 2019\",\"authors\":\"Afsaneh Mostagim Ahmadabadi, F. Sahbaeiroy, S. Hejazi\",\"doi\":\"10.52547/iau.31.4.450\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The incidence of neural bladder is increasing today and these people need catheterization. Intermittent clean urinary catheterization is a low-risk method for the patients. Materials and methods: This was a descriptive methodological and validation research. For content validity, 10 people were selected by purposive method. For face validity, 25 people were chosen by convenience method Aimed at structural validity, gradual method was used from sounding conductors. For the reliability of the questionnaire, 10 people completed the questionnaire. Results: First, a draft was developed and two qualitative and quantitative methods were used for face validity. The effect scores of the items were not less than 1.5. None of the items less than 62% were deleted according to the table. In construct validity, exploratory factor analysis and varimax rotation methods were used and the adequacy of sample size was 0.78 by KMO test, and the results of Bartlett sphericity test were significant (4017/486 p <0.001). 5 items with a share of less than 0.4 were removed and factor analysis was performed again and the number of factors was reduced to four with a variance of 40.136. The results of internal consistency of Cronbach's alpha coefficient of the whole questionnaire with 32 items were equal to 0.862 and 0.859 for women and men respectively. The results of the stability of the verification tools and the result of the ICC test (0.949) showed a good correlation coefficient for each structure. Conclusion: The tools designed in this study are valid and reliable and can be used in various studies.\",\"PeriodicalId\":18492,\"journal\":{\"name\":\"MEDICAL SCIENCES JOURNAL\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MEDICAL SCIENCES JOURNAL\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52547/iau.31.4.450\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MEDICAL SCIENCES JOURNAL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52547/iau.31.4.450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
背景:神经性膀胱的发病率呈上升趋势,需要导尿。间歇清洁导尿是一种低风险的方法。材料和方法:本研究为描述性方法学和验证性研究。内容效度采用目的法选取10人。对于面孔效度,采用便利法选取25人;对于结构效度,采用从测音者开始的渐进法。为保证问卷的信度,共10人完成问卷。结果:首先,制定了一份草案,并采用了定性和定量两种方法进行了人脸效度测试。各题效分均不低于1.5分。根据该表,小于62%的项均未被删除。结构效度采用探索性因子分析和变量旋转法,KMO检验的样本量充分性为0.78,Bartlett球形检验的结果具有显著性(4017/486 p <0.001)。剔除份额小于0.4的5项,重新进行因子分析,将因子数量减少到4个,方差为40.136。整个32项问卷的Cronbach’s alpha系数的内部一致性结果,女性为0.862,男性为0.859。验证工具的稳定性与ICC检验结果(0.949)表明,各结构均具有良好的相关系数。结论:本研究设计的工具有效可靠,可用于各种研究。
Psychometrics of the self-efficacy instrument of clean intermittent urinary catheterization in patients with neural bladder admitted to rehabilitation hospitals in Tehran in 2019
Background: The incidence of neural bladder is increasing today and these people need catheterization. Intermittent clean urinary catheterization is a low-risk method for the patients. Materials and methods: This was a descriptive methodological and validation research. For content validity, 10 people were selected by purposive method. For face validity, 25 people were chosen by convenience method Aimed at structural validity, gradual method was used from sounding conductors. For the reliability of the questionnaire, 10 people completed the questionnaire. Results: First, a draft was developed and two qualitative and quantitative methods were used for face validity. The effect scores of the items were not less than 1.5. None of the items less than 62% were deleted according to the table. In construct validity, exploratory factor analysis and varimax rotation methods were used and the adequacy of sample size was 0.78 by KMO test, and the results of Bartlett sphericity test were significant (4017/486 p <0.001). 5 items with a share of less than 0.4 were removed and factor analysis was performed again and the number of factors was reduced to four with a variance of 40.136. The results of internal consistency of Cronbach's alpha coefficient of the whole questionnaire with 32 items were equal to 0.862 and 0.859 for women and men respectively. The results of the stability of the verification tools and the result of the ICC test (0.949) showed a good correlation coefficient for each structure. Conclusion: The tools designed in this study are valid and reliable and can be used in various studies.