{"title":"不同桩体加固根管治疗后牙体抗折性的比较研究","authors":"S. Ramachandran, S. Babu, M. ., Ranukumari .","doi":"10.7860/jcdr/2023/59459.17694","DOIUrl":null,"url":null,"abstract":"Introduction: Endodontically treated tooth reinforced with posts should restore its lost structural integrity, as well as withstand the various masticatory forces. Choosing the appropriate post, so that a durable prosthesis can be given, is often a challenge to a restorative dentist. Aim: To compare the resistance to fracture, of endodontically treated teeth restored with the various posts when subjected to compressive loads, and analyse the different types of fractures and cracks which are visible under normal eye, microscope and radiograph. Materials and Methods: An in-vitro study was conducted in the Department of Dentistry, Pondicherry Institute of Medical Sciences, Puducherry, India, from February 2019 to March 2020. Study was done with four types of posts namely cast post, stainless steel, fibre and titanium on seventy extracted teeth, which were randomly allocated into five groups with one group as control without any post. The teeth were subjected to increasing compressive loads with universal testing machine and the loads at which fracture occurred was recorded. The data was analysed statistically with one way Analysis of Variance (ANOVA) and the groups were compared with Tukey’s HSD test. The types of fractures that occurred were also analysed. Results: The loads at which the teeth reinforced with various posts fractured, showed significant difference (p-value <0.0001). The mean load at which fracture occurred for teeth restored without any posts was 711.6086 N and teeth with stainless steel post was highest at 1605.955 N. Those with titanium posts were found to have minimum microcracks (14.2%) when seen under dissection microscope. Maximum number of teeth with titanium posts had favourable fracture and withstood the load (64.29%), with fracture occurring only at root tip and no fracture elsewhere. Tukey’s HSD test was done to compare the fracture resistance between the groups at 0.05 level of significance. There was no significant difference in the load at which fracture occurred between groups. Conclusion: In the present study, of all different post and core materials, stainless steel post resisted highest load and titanium posts had favourable fractures.","PeriodicalId":15483,"journal":{"name":"JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH","volume":"30 1","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Resistance to Fracture of Endodontically Treated Teeth Reinforced with Various Posts: An In-vitro Study\",\"authors\":\"S. Ramachandran, S. Babu, M. ., Ranukumari .\",\"doi\":\"10.7860/jcdr/2023/59459.17694\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Endodontically treated tooth reinforced with posts should restore its lost structural integrity, as well as withstand the various masticatory forces. Choosing the appropriate post, so that a durable prosthesis can be given, is often a challenge to a restorative dentist. Aim: To compare the resistance to fracture, of endodontically treated teeth restored with the various posts when subjected to compressive loads, and analyse the different types of fractures and cracks which are visible under normal eye, microscope and radiograph. Materials and Methods: An in-vitro study was conducted in the Department of Dentistry, Pondicherry Institute of Medical Sciences, Puducherry, India, from February 2019 to March 2020. Study was done with four types of posts namely cast post, stainless steel, fibre and titanium on seventy extracted teeth, which were randomly allocated into five groups with one group as control without any post. The teeth were subjected to increasing compressive loads with universal testing machine and the loads at which fracture occurred was recorded. The data was analysed statistically with one way Analysis of Variance (ANOVA) and the groups were compared with Tukey’s HSD test. The types of fractures that occurred were also analysed. Results: The loads at which the teeth reinforced with various posts fractured, showed significant difference (p-value <0.0001). The mean load at which fracture occurred for teeth restored without any posts was 711.6086 N and teeth with stainless steel post was highest at 1605.955 N. Those with titanium posts were found to have minimum microcracks (14.2%) when seen under dissection microscope. Maximum number of teeth with titanium posts had favourable fracture and withstood the load (64.29%), with fracture occurring only at root tip and no fracture elsewhere. Tukey’s HSD test was done to compare the fracture resistance between the groups at 0.05 level of significance. There was no significant difference in the load at which fracture occurred between groups. Conclusion: In the present study, of all different post and core materials, stainless steel post resisted highest load and titanium posts had favourable fractures.\",\"PeriodicalId\":15483,\"journal\":{\"name\":\"JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH\",\"volume\":\"30 1\",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7860/jcdr/2023/59459.17694\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7860/jcdr/2023/59459.17694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

介绍:根管治疗后的牙柱加固后,可以恢复失去的结构完整性,并能承受各种咀嚼力。选择合适的位置,以便提供耐用的假体,对修复牙医来说往往是一个挑战。目的:比较不同根管桩对根管治疗后的牙体在压缩载荷作用下的抗折能力,并分析正常肉眼、显微镜和x线片下可见的不同类型的断裂和裂缝。材料与方法:2019年2月至2020年3月,在印度普杜切里本地治里医学科学研究所牙科学系进行了一项体外研究。采用铸造桩、不锈钢桩、纤维桩和钛桩四种类型的桩对70颗拔牙进行研究,随机分为五组,其中一组为对照组,不设桩。在万能试验机上对牙进行了不断增加的压缩载荷试验,并记录了发生断裂的载荷。数据采用单因素方差分析(ANOVA)进行统计学分析,组间比较采用Tukey’s HSD检验。对发生的骨折类型也进行了分析。结果:不同桩加固牙在载荷作用下发生断裂,差异有统计学意义(p值<0.0001)。无桩修复牙发生断裂的平均载荷为711.6086 N,不锈钢桩修复牙发生断裂的平均载荷为1605.955 N,钛桩修复牙在解剖显微镜下微裂纹最小(14.2%)。有钛桩的牙最多(64.29%)有良好的断裂和承受载荷,仅在根尖发生断裂,其他部位无断裂。采用Tukey’s HSD检验比较各组间抗骨折能力,差异在0.05水平上具有显著性。各组之间发生骨折的负荷无显著差异。结论:在不同的桩芯材料中,不锈钢桩承受的载荷最大,钛桩具有良好的骨折效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of Resistance to Fracture of Endodontically Treated Teeth Reinforced with Various Posts: An In-vitro Study
Introduction: Endodontically treated tooth reinforced with posts should restore its lost structural integrity, as well as withstand the various masticatory forces. Choosing the appropriate post, so that a durable prosthesis can be given, is often a challenge to a restorative dentist. Aim: To compare the resistance to fracture, of endodontically treated teeth restored with the various posts when subjected to compressive loads, and analyse the different types of fractures and cracks which are visible under normal eye, microscope and radiograph. Materials and Methods: An in-vitro study was conducted in the Department of Dentistry, Pondicherry Institute of Medical Sciences, Puducherry, India, from February 2019 to March 2020. Study was done with four types of posts namely cast post, stainless steel, fibre and titanium on seventy extracted teeth, which were randomly allocated into five groups with one group as control without any post. The teeth were subjected to increasing compressive loads with universal testing machine and the loads at which fracture occurred was recorded. The data was analysed statistically with one way Analysis of Variance (ANOVA) and the groups were compared with Tukey’s HSD test. The types of fractures that occurred were also analysed. Results: The loads at which the teeth reinforced with various posts fractured, showed significant difference (p-value <0.0001). The mean load at which fracture occurred for teeth restored without any posts was 711.6086 N and teeth with stainless steel post was highest at 1605.955 N. Those with titanium posts were found to have minimum microcracks (14.2%) when seen under dissection microscope. Maximum number of teeth with titanium posts had favourable fracture and withstood the load (64.29%), with fracture occurring only at root tip and no fracture elsewhere. Tukey’s HSD test was done to compare the fracture resistance between the groups at 0.05 level of significance. There was no significant difference in the load at which fracture occurred between groups. Conclusion: In the present study, of all different post and core materials, stainless steel post resisted highest load and titanium posts had favourable fractures.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH MEDICINE, GENERAL & INTERNAL-
自引率
0.00%
发文量
761
审稿时长
12 weeks
期刊介绍: Specialties Covered: Anaesthesia, Anatomy, Animal Research, Biochemistry, Biotechnology, Cardiology, Community, Dermatology, Dentistry, Education, Emergency Medicine, Endocrinology, Ethics, Ear Nose and Throat, Forensic, Gastroenterology, Genetics, Haematology, Health Management and Policy, Immunology and Infectious Diseases, Intensive Care, Internal Medicine, Microbiology, Health Management and Policy, Immunology and Infectious Diseases, Intensive Care, Internal Medicine, Microbiology, Nephrology / Renal, Neurology and Neuro-Surgery, Nutrition, Nursing/Midwifery, Oncology, Orthopaedics, Ophthalmology, Obstetrics and Gynaecology, Paediatrics and Neonatology Pharmacology, Physiology, Pathology, Plastic Surgery, Psychiatry/Mental Health, Rehabilitation / Physiotherapy, Radiology, Statistics, Surgery, Speech and Hearing (Audiology)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信