含10- mdp与不含10- mdp胶粘剂在不同程度氟斑牙中的粘结强度比较

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
Luis Javier Solís-Martínez, Karla Yareli Valles Flores, Nohé Vargas Chávez, O. Almeda-Ojeda, Víctor Hiram Barajas-Pérez, Edgar García-Torres
{"title":"含10- mdp与不含10- mdp胶粘剂在不同程度氟斑牙中的粘结强度比较","authors":"Luis Javier Solís-Martínez, Karla Yareli Valles Flores, Nohé Vargas Chávez, O. Almeda-Ojeda, Víctor Hiram Barajas-Pérez, Edgar García-Torres","doi":"10.15517/ijds.2022.52446","DOIUrl":null,"url":null,"abstract":"Dental fluorosis can cause changes in the enamel surface, conditioning its functionality and esthetics. The application of dental adhesives is a treatment option; however, their use on fluorotic teeth can result in limitations. The aim of this study was to compare the shear bond strength of two different adhesives, one with 10-MDP and one without 10-MDP, in different degrees of dental fluorosis.This is an in vitro study on dental enamel samples, a total of 180 samples with the inclusion criteria were treated, randomly divided into two groups of 90, according to the type of dental adhesive, where each group was again divided into three groups of 30 samples, representing different degrees of dental fluorosis according to the Thylstrup-Fejerskov index (Group I: TF1 and TF2; Group II: TF3; Group III: TF4). Normality tests, two-factor ANOVA, and post-hoc tests were used to determine differences between the groups, with a significance level of 95%. As results, a statistically significant difference was shown between the use of dental adhesive with 10-MDP and the three groups of dental fluorosis (p=0.011), in addition, a Tukey post-hoc test on the groups treated with 10-MDP adhesive revealed a statistically significant difference between group I versus group II, and group I versus group III, (p=<0.05). It is concluded that the use of adhesive systems with 10-MDP presents a better shear bond strength on enamel with dental fluorosis grades I and II in the Thylstrup-Fejerskov index.","PeriodicalId":19450,"journal":{"name":"Odovtos - International Journal of Dental Sciences","volume":"32 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2022-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bond Strength Comparison Among 10-MDP-Containing and Non-10-MDP-Containing Adhesives in Different Degrees of Dental Fluorosis\",\"authors\":\"Luis Javier Solís-Martínez, Karla Yareli Valles Flores, Nohé Vargas Chávez, O. Almeda-Ojeda, Víctor Hiram Barajas-Pérez, Edgar García-Torres\",\"doi\":\"10.15517/ijds.2022.52446\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Dental fluorosis can cause changes in the enamel surface, conditioning its functionality and esthetics. The application of dental adhesives is a treatment option; however, their use on fluorotic teeth can result in limitations. The aim of this study was to compare the shear bond strength of two different adhesives, one with 10-MDP and one without 10-MDP, in different degrees of dental fluorosis.This is an in vitro study on dental enamel samples, a total of 180 samples with the inclusion criteria were treated, randomly divided into two groups of 90, according to the type of dental adhesive, where each group was again divided into three groups of 30 samples, representing different degrees of dental fluorosis according to the Thylstrup-Fejerskov index (Group I: TF1 and TF2; Group II: TF3; Group III: TF4). Normality tests, two-factor ANOVA, and post-hoc tests were used to determine differences between the groups, with a significance level of 95%. As results, a statistically significant difference was shown between the use of dental adhesive with 10-MDP and the three groups of dental fluorosis (p=0.011), in addition, a Tukey post-hoc test on the groups treated with 10-MDP adhesive revealed a statistically significant difference between group I versus group II, and group I versus group III, (p=<0.05). It is concluded that the use of adhesive systems with 10-MDP presents a better shear bond strength on enamel with dental fluorosis grades I and II in the Thylstrup-Fejerskov index.\",\"PeriodicalId\":19450,\"journal\":{\"name\":\"Odovtos - International Journal of Dental Sciences\",\"volume\":\"32 1\",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Odovtos - International Journal of Dental Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15517/ijds.2022.52446\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odovtos - International Journal of Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15517/ijds.2022.52446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

氟斑牙会引起牙釉质表面的变化,影响其功能和美观。使用牙胶粘剂是一种治疗选择;然而,它们在含氟牙齿上的使用可能会导致局限性。本研究旨在比较含10-MDP和不含10-MDP两种不同黏合剂在不同程度氟牙症中的剪切粘接强度。这是一项牙釉质样品的体外研究,共对180个符合纳入标准的样品进行处理,根据牙胶粘剂的类型随机分为两组,每组90个,其中每组再根据thylstrp - fejerskov指数分为三组,每组30个样品,代表不同程度的氟牙症(第一组:TF1和TF2;第二组:TF3;第三组:TF4)。采用正态性检验、双因素方差分析和事后检验来确定组间差异,显著性水平为95%。结果显示,使用含10-MDP牙胶粘剂与三组氟牙症的差异有统计学意义(p=0.011),并且对使用10-MDP牙胶粘剂组进行Tukey事后检验显示,1组与2组、1组与3组的差异有统计学意义(p=<0.05)。综上所述,10-MDP粘接体系对Thylstrup-Fejerskov指数I级和II级氟牙症牙釉质具有较好的剪切粘接强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Bond Strength Comparison Among 10-MDP-Containing and Non-10-MDP-Containing Adhesives in Different Degrees of Dental Fluorosis
Dental fluorosis can cause changes in the enamel surface, conditioning its functionality and esthetics. The application of dental adhesives is a treatment option; however, their use on fluorotic teeth can result in limitations. The aim of this study was to compare the shear bond strength of two different adhesives, one with 10-MDP and one without 10-MDP, in different degrees of dental fluorosis.This is an in vitro study on dental enamel samples, a total of 180 samples with the inclusion criteria were treated, randomly divided into two groups of 90, according to the type of dental adhesive, where each group was again divided into three groups of 30 samples, representing different degrees of dental fluorosis according to the Thylstrup-Fejerskov index (Group I: TF1 and TF2; Group II: TF3; Group III: TF4). Normality tests, two-factor ANOVA, and post-hoc tests were used to determine differences between the groups, with a significance level of 95%. As results, a statistically significant difference was shown between the use of dental adhesive with 10-MDP and the three groups of dental fluorosis (p=0.011), in addition, a Tukey post-hoc test on the groups treated with 10-MDP adhesive revealed a statistically significant difference between group I versus group II, and group I versus group III, (p=<0.05). It is concluded that the use of adhesive systems with 10-MDP presents a better shear bond strength on enamel with dental fluorosis grades I and II in the Thylstrup-Fejerskov index.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Odovtos - International Journal of Dental Sciences
Odovtos - International Journal of Dental Sciences DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.00
自引率
0.00%
发文量
50
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信