{"title":"用响应面法模拟统计方法确定平房建筑的最佳隔热层和水泥灰泥厚度","authors":"I. Asadi, P. Shafigh, N. Mahyuddin, H. Akbari","doi":"10.22452/jdbe.vol19no2.4","DOIUrl":null,"url":null,"abstract":"Insulating interior side of external wall and finishing by cement plaster is one of the most appropriate methods of reducing annual energy consumption in available buildings. The aim of this study is to determine the optimum expanded polystyrene (EPS) and cement plaster thickness for bungalow building in Malaysia. The present study evaluates the effect of different thermal insulation and interior cement plaster thicknesses on the annual cooling energy consumption. Furthermore, the optimum thickness of EPS and plaster is estimated based on wall type and building orientation. Two different types of walls made of concrete and brick are considered. EPS and plaster were used in the range of 20 to 100 mm and 0 to 20mm, respectively. The results show that both thermal insulation and plaster thickness have a direct effect on annual cooling energy consumption, however, the influence of wall thermal insulation thickness is more significant than cement plaster thickness. Further, the optimum EPS thickness decreases with the increment in cement plaster thickness for different orientations and wall types. The optimum EPS thickness ranges from 31.5 mm to 53.1 mm based on wall type, orientation and cement plaster thickness. Utilizing optimum EPS and cement plaster thicknesses can thus reduce annual energy consumption by about 6 to 12% in different directions.","PeriodicalId":37954,"journal":{"name":"Journal of Design and Built Environment","volume":"66 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Determination of optimum insulation and cement plaster thickness for bungalow buildings through a simulation-statistical approach using response surface methodology\",\"authors\":\"I. Asadi, P. Shafigh, N. Mahyuddin, H. Akbari\",\"doi\":\"10.22452/jdbe.vol19no2.4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Insulating interior side of external wall and finishing by cement plaster is one of the most appropriate methods of reducing annual energy consumption in available buildings. The aim of this study is to determine the optimum expanded polystyrene (EPS) and cement plaster thickness for bungalow building in Malaysia. The present study evaluates the effect of different thermal insulation and interior cement plaster thicknesses on the annual cooling energy consumption. Furthermore, the optimum thickness of EPS and plaster is estimated based on wall type and building orientation. Two different types of walls made of concrete and brick are considered. EPS and plaster were used in the range of 20 to 100 mm and 0 to 20mm, respectively. The results show that both thermal insulation and plaster thickness have a direct effect on annual cooling energy consumption, however, the influence of wall thermal insulation thickness is more significant than cement plaster thickness. Further, the optimum EPS thickness decreases with the increment in cement plaster thickness for different orientations and wall types. The optimum EPS thickness ranges from 31.5 mm to 53.1 mm based on wall type, orientation and cement plaster thickness. Utilizing optimum EPS and cement plaster thicknesses can thus reduce annual energy consumption by about 6 to 12% in different directions.\",\"PeriodicalId\":37954,\"journal\":{\"name\":\"Journal of Design and Built Environment\",\"volume\":\"66 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Design and Built Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22452/jdbe.vol19no2.4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Design and Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22452/jdbe.vol19no2.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
Determination of optimum insulation and cement plaster thickness for bungalow buildings through a simulation-statistical approach using response surface methodology
Insulating interior side of external wall and finishing by cement plaster is one of the most appropriate methods of reducing annual energy consumption in available buildings. The aim of this study is to determine the optimum expanded polystyrene (EPS) and cement plaster thickness for bungalow building in Malaysia. The present study evaluates the effect of different thermal insulation and interior cement plaster thicknesses on the annual cooling energy consumption. Furthermore, the optimum thickness of EPS and plaster is estimated based on wall type and building orientation. Two different types of walls made of concrete and brick are considered. EPS and plaster were used in the range of 20 to 100 mm and 0 to 20mm, respectively. The results show that both thermal insulation and plaster thickness have a direct effect on annual cooling energy consumption, however, the influence of wall thermal insulation thickness is more significant than cement plaster thickness. Further, the optimum EPS thickness decreases with the increment in cement plaster thickness for different orientations and wall types. The optimum EPS thickness ranges from 31.5 mm to 53.1 mm based on wall type, orientation and cement plaster thickness. Utilizing optimum EPS and cement plaster thicknesses can thus reduce annual energy consumption by about 6 to 12% in different directions.
期刊介绍:
The Journal of Design and Built Environment (JDBE) is a SCOPUS-indexed and free open access publication by the Faculty of Built Environment, University of Malaya. Published biannually, JDBE usually contains four academic papers of wide-ranging topics reporting on issues in the built environment, i.e. architecture and design including landscape architecture, urban and regional planning and studies, building and quantity surveys and real estate studies and management.