利用PVsyst软件分析塞内加尔四个典型气候带50kwp自用太阳能光伏系统的可行性

Adama Sarr, C. F. Kébé, Ababacar Ndiaye
{"title":"利用PVsyst软件分析塞内加尔四个典型气候带50kwp自用太阳能光伏系统的可行性","authors":"Adama Sarr, C. F. Kébé, Ababacar Ndiaye","doi":"10.5897/IJPS2020.4916","DOIUrl":null,"url":null,"abstract":"This study investigates analysis and feasibility of 50 kWp self-consumption photovoltaic system used for supplying the electrical load of military bases in Senegal. It refers to a simulation of performance photovoltaic system in four Senegalese typical climatic zones. In constructing the 50 kWp self-consumption photovoltaic simulation, the number of modules is 144, the power of each module is 280 Wp, 18 modules are in series and 8 in strings. Also, two solar SMA technology of 20 kWp with a voltage range of 230 to 800 V are used, and the simulation is done by means of Pvsyst software 6.81. Solar and ambient temperature data sets from Helioclim-3 database corrected by observations are used for this performance study. The variability of performance system in the four climate typical zones are analyzed from the simulations results. This work includes evaluation of the effective energy produced by the photovoltaic system, consumption and other components related to PV production for each climatic region. The 50 kWp PV array of electricity produced at Dakar (69.8 MWh/year), St Louis (64.9 MWh/year), Tambacounda (62.7 MWh/year) and Ziguinchor (59.3 MWh/year) is entirely self-consumed. The annual performance ratio are 0.796 at Dakar, 0.795 at St Louis, 0.775 at Tambacounda and 0.792 at Ziguinchor. The results obtained follow the variability of the solar resource. This variability is often impacted by the effect of temperature and other local climatic conditions such as the number of aerosols and the diversity of seasons. The solar radiation is more important at St Louis than at Dakar but the Dakar region is less impacted by these factors, making the results more important at Dakar. As for the Tambacounda and Ziguinchor regions, the solar resource is less important, likely due to effect of elevated PV panel temperatures and a longer rainy season in these two zones. To know the magnitude of a solar photovoltaic installation, it is good to size for each locality to be able to deduce a larger production. \n \n Key words: Self-consumption, Pvsyst software, climatic zones, Helioclim-3, performance ratio.","PeriodicalId":14294,"journal":{"name":"International Journal of Physical Sciences","volume":"42 1","pages":"201-212"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Analysis and feasibility of 50 kWp self-consumption solar photovoltaic system for four Senegalese typical climatic zones using PVsyst software\",\"authors\":\"Adama Sarr, C. F. Kébé, Ababacar Ndiaye\",\"doi\":\"10.5897/IJPS2020.4916\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study investigates analysis and feasibility of 50 kWp self-consumption photovoltaic system used for supplying the electrical load of military bases in Senegal. It refers to a simulation of performance photovoltaic system in four Senegalese typical climatic zones. In constructing the 50 kWp self-consumption photovoltaic simulation, the number of modules is 144, the power of each module is 280 Wp, 18 modules are in series and 8 in strings. Also, two solar SMA technology of 20 kWp with a voltage range of 230 to 800 V are used, and the simulation is done by means of Pvsyst software 6.81. Solar and ambient temperature data sets from Helioclim-3 database corrected by observations are used for this performance study. The variability of performance system in the four climate typical zones are analyzed from the simulations results. This work includes evaluation of the effective energy produced by the photovoltaic system, consumption and other components related to PV production for each climatic region. The 50 kWp PV array of electricity produced at Dakar (69.8 MWh/year), St Louis (64.9 MWh/year), Tambacounda (62.7 MWh/year) and Ziguinchor (59.3 MWh/year) is entirely self-consumed. The annual performance ratio are 0.796 at Dakar, 0.795 at St Louis, 0.775 at Tambacounda and 0.792 at Ziguinchor. The results obtained follow the variability of the solar resource. This variability is often impacted by the effect of temperature and other local climatic conditions such as the number of aerosols and the diversity of seasons. The solar radiation is more important at St Louis than at Dakar but the Dakar region is less impacted by these factors, making the results more important at Dakar. As for the Tambacounda and Ziguinchor regions, the solar resource is less important, likely due to effect of elevated PV panel temperatures and a longer rainy season in these two zones. To know the magnitude of a solar photovoltaic installation, it is good to size for each locality to be able to deduce a larger production. \\n \\n Key words: Self-consumption, Pvsyst software, climatic zones, Helioclim-3, performance ratio.\",\"PeriodicalId\":14294,\"journal\":{\"name\":\"International Journal of Physical Sciences\",\"volume\":\"42 1\",\"pages\":\"201-212\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Physical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5897/IJPS2020.4916\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Physical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5897/IJPS2020.4916","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文对塞内加尔军事基地50 kWp自用光伏系统供电负荷的分析与可行性进行了研究。本文对塞内加尔四个典型气候带的光伏系统性能进行了模拟。在构建50 kWp自用光伏仿真时,模块数为144个,每个模块功率为280 Wp, 18个模块串联,8个模块串接。采用两种20 kWp的太阳能SMA技术,电压范围为230 ~ 800 V,并利用Pvsyst软件6.81进行了仿真。本性能研究使用了经观测校正的Helioclim-3数据库的太阳和环境温度数据集。根据模拟结果,分析了4个典型气候区性能系统的变异性。这项工作包括评估光伏系统产生的有效能量,每个气候区域的消耗和与光伏生产相关的其他组件。达喀尔(69.8兆瓦时/年)、圣路易斯(64.9兆瓦时/年)、Tambacounda(62.7兆瓦时/年)和ziiguinchor(59.3兆瓦时/年)生产的50千瓦时光伏发电阵列完全是自用的。达喀尔的年业绩比为0.796,圣路易斯为0.795,Tambacounda为0.775,Ziguinchor为0.792。所得结果遵循太阳资源的变化。这种变率常常受到温度和其他当地气候条件的影响,例如气溶胶的数量和季节的多样性。圣路易斯的太阳辐射比达喀尔更重要,但达喀尔地区受这些因素的影响较小,因此达喀尔的结果更重要。至于Tambacounda和Ziguinchor地区,太阳能资源不那么重要,可能是由于这两个地区的光伏板温度升高和雨季较长。要知道太阳能光伏装置的大小,最好是每个地方的尺寸,以便能够推断出更大的产量。关键词:自用,Pvsyst软件,气候带,Helioclim-3,性能比
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis and feasibility of 50 kWp self-consumption solar photovoltaic system for four Senegalese typical climatic zones using PVsyst software
This study investigates analysis and feasibility of 50 kWp self-consumption photovoltaic system used for supplying the electrical load of military bases in Senegal. It refers to a simulation of performance photovoltaic system in four Senegalese typical climatic zones. In constructing the 50 kWp self-consumption photovoltaic simulation, the number of modules is 144, the power of each module is 280 Wp, 18 modules are in series and 8 in strings. Also, two solar SMA technology of 20 kWp with a voltage range of 230 to 800 V are used, and the simulation is done by means of Pvsyst software 6.81. Solar and ambient temperature data sets from Helioclim-3 database corrected by observations are used for this performance study. The variability of performance system in the four climate typical zones are analyzed from the simulations results. This work includes evaluation of the effective energy produced by the photovoltaic system, consumption and other components related to PV production for each climatic region. The 50 kWp PV array of electricity produced at Dakar (69.8 MWh/year), St Louis (64.9 MWh/year), Tambacounda (62.7 MWh/year) and Ziguinchor (59.3 MWh/year) is entirely self-consumed. The annual performance ratio are 0.796 at Dakar, 0.795 at St Louis, 0.775 at Tambacounda and 0.792 at Ziguinchor. The results obtained follow the variability of the solar resource. This variability is often impacted by the effect of temperature and other local climatic conditions such as the number of aerosols and the diversity of seasons. The solar radiation is more important at St Louis than at Dakar but the Dakar region is less impacted by these factors, making the results more important at Dakar. As for the Tambacounda and Ziguinchor regions, the solar resource is less important, likely due to effect of elevated PV panel temperatures and a longer rainy season in these two zones. To know the magnitude of a solar photovoltaic installation, it is good to size for each locality to be able to deduce a larger production. Key words: Self-consumption, Pvsyst software, climatic zones, Helioclim-3, performance ratio.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Physical Sciences
International Journal of Physical Sciences 综合性期刊-综合性期刊
自引率
0.00%
发文量
4
审稿时长
24 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信