{"title":"自由镜头戴式显示器的设计","authors":"Congshan Rui, Chun-mei Zeng, Tian-tian Hu, Suo-dong Ma","doi":"10.1117/12.2531787","DOIUrl":null,"url":null,"abstract":"A head-mounted display (HMD) requires a large field of view (FOV) and a large exit pupil diameter while maintaining a compact structure. In this paper, we show a head-mounted display design comprising two freeform mirrors covering a 28° full field-of-view with an eye relief of 15mm. The simplified partial differential equation (PDE) method is applied in the design of a two-mirror HMD system. Then the data points on the unknown freeform mirrors are calculated using the rays from multiple fields and are used to construct the freeform mirrors in the HMD system, which is taken as a starting point. This simplified partial differential equation method makes calculations easier. The anamorphic surface and the XY polynomial freeform surface are used in the two freeform mirrors for improving the image quality, respectively. The optimization strategy is also described in detail. The final HMD system operates at F/3.75 with 8mm exit pupil diameter achieving good imaging performance.","PeriodicalId":10843,"journal":{"name":"Current Developments in Lens Design and Optical Engineering XX","volume":"125 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of a head-mounted display with freeform mirrors\",\"authors\":\"Congshan Rui, Chun-mei Zeng, Tian-tian Hu, Suo-dong Ma\",\"doi\":\"10.1117/12.2531787\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A head-mounted display (HMD) requires a large field of view (FOV) and a large exit pupil diameter while maintaining a compact structure. In this paper, we show a head-mounted display design comprising two freeform mirrors covering a 28° full field-of-view with an eye relief of 15mm. The simplified partial differential equation (PDE) method is applied in the design of a two-mirror HMD system. Then the data points on the unknown freeform mirrors are calculated using the rays from multiple fields and are used to construct the freeform mirrors in the HMD system, which is taken as a starting point. This simplified partial differential equation method makes calculations easier. The anamorphic surface and the XY polynomial freeform surface are used in the two freeform mirrors for improving the image quality, respectively. The optimization strategy is also described in detail. The final HMD system operates at F/3.75 with 8mm exit pupil diameter achieving good imaging performance.\",\"PeriodicalId\":10843,\"journal\":{\"name\":\"Current Developments in Lens Design and Optical Engineering XX\",\"volume\":\"125 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Developments in Lens Design and Optical Engineering XX\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2531787\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Developments in Lens Design and Optical Engineering XX","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2531787","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

头戴式显示器(HMD)需要大的视野(FOV)和大的出口瞳孔直径,同时保持紧凑的结构。在本文中,我们展示了一种头戴式显示器设计,该设计包括两个自由曲面镜,覆盖28°全视野,眼距为15mm。将简化偏微分方程(PDE)方法应用于双镜HMD系统的设计。然后利用多场射线计算未知自由曲面反射镜上的数据点,并以此为起点构建HMD系统中的自由曲面反射镜。这种简化的偏微分方程方法使计算更容易。为了提高成像质量,两个自由曲面分别采用变形曲面和XY多项式自由曲面。并对优化策略进行了详细的描述。最终的HMD系统在F/3.75下工作,出瞳直径为8mm,具有良好的成像性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of a head-mounted display with freeform mirrors
A head-mounted display (HMD) requires a large field of view (FOV) and a large exit pupil diameter while maintaining a compact structure. In this paper, we show a head-mounted display design comprising two freeform mirrors covering a 28° full field-of-view with an eye relief of 15mm. The simplified partial differential equation (PDE) method is applied in the design of a two-mirror HMD system. Then the data points on the unknown freeform mirrors are calculated using the rays from multiple fields and are used to construct the freeform mirrors in the HMD system, which is taken as a starting point. This simplified partial differential equation method makes calculations easier. The anamorphic surface and the XY polynomial freeform surface are used in the two freeform mirrors for improving the image quality, respectively. The optimization strategy is also described in detail. The final HMD system operates at F/3.75 with 8mm exit pupil diameter achieving good imaging performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信