{"title":"湿绝缘表面电场计算","authors":"B. Sarang, P. Basappa, V. Lakdawala","doi":"10.1109/CEIDP.2008.4772834","DOIUrl":null,"url":null,"abstract":"Presence of water droplets over the insulator surface enhances the electric field intensity and leads to electrical breakdown. This is important for outdoor insulation because the combination of moisture and contamination causes flashover at operating voltage; hence affects reliability of power delivery. Electric field has been calculated on insulating surfaces for different patterns of wetting. Simulations have been conducted by varying the number of water droplets, their relative positions and contact angle on the insulator surface in the sheath region. They are simulated using a 3D Electric Field Analysis computer package (Coulomb). One important outcome of this work, is that location of the water droplets with respect to electrodes and other droplets are crucial in determining the maximum E-Field intensity and hence the flash over voltage.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Electric field calculations of wet insulating surfaces\",\"authors\":\"B. Sarang, P. Basappa, V. Lakdawala\",\"doi\":\"10.1109/CEIDP.2008.4772834\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Presence of water droplets over the insulator surface enhances the electric field intensity and leads to electrical breakdown. This is important for outdoor insulation because the combination of moisture and contamination causes flashover at operating voltage; hence affects reliability of power delivery. Electric field has been calculated on insulating surfaces for different patterns of wetting. Simulations have been conducted by varying the number of water droplets, their relative positions and contact angle on the insulator surface in the sheath region. They are simulated using a 3D Electric Field Analysis computer package (Coulomb). One important outcome of this work, is that location of the water droplets with respect to electrodes and other droplets are crucial in determining the maximum E-Field intensity and hence the flash over voltage.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772834\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772834","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

绝缘子表面水滴的存在增强了电场强度并导致电击穿。这对室外绝缘很重要,因为潮湿和污染的结合会在工作电压下引起闪络;从而影响供电的可靠性。计算了不同润湿方式下绝缘表面上的电场。通过改变护套区域绝缘子表面水滴的数量、相对位置和接触角进行了模拟。它们是用三维电场分析计算机包(库仑)模拟的。这项工作的一个重要成果是,水滴相对于电极和其他水滴的位置对于确定最大电场强度和闪光过电压至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electric field calculations of wet insulating surfaces
Presence of water droplets over the insulator surface enhances the electric field intensity and leads to electrical breakdown. This is important for outdoor insulation because the combination of moisture and contamination causes flashover at operating voltage; hence affects reliability of power delivery. Electric field has been calculated on insulating surfaces for different patterns of wetting. Simulations have been conducted by varying the number of water droplets, their relative positions and contact angle on the insulator surface in the sheath region. They are simulated using a 3D Electric Field Analysis computer package (Coulomb). One important outcome of this work, is that location of the water droplets with respect to electrodes and other droplets are crucial in determining the maximum E-Field intensity and hence the flash over voltage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信