{"title":"热电厂脉冲功率去除NO/sub x/和SO/sub 2/","authors":"S. Tsukamoto, T. Namihira, D. Wang, S. Katsuki, H. Akiyama, E. Nakashima, A. Sato, Y. Uchida, M. Koike","doi":"10.1109/PPC.1999.823772","DOIUrl":null,"url":null,"abstract":"Recently various methods involving gas discharges and electron beams have been studied for the removal of NO/sub x/ and SO/sub 2/ from flue gases. The recent development of repetitive pulsed power generators gives the pulsed streamer corona discharges a chance of success in the removal of NO/sub x/ and SO/sub 2/. Experiments for the removal of NO/sub x/ and SO/sub 2/ using actual flue gases were performed at a thermal power plant. The results showed that about 90% of NO and about 50% of SO/sub 2/ were removed at a flow rate of 0.8 l/min and a repetition rate of 7 pulses per second (pps). The removal ratio of NO varied inversely proportional to the gas flow rate. The energy efficiency of NO removal was 900 /spl mu/mol/Wh when 50% of NO was removed.","PeriodicalId":11209,"journal":{"name":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","volume":"1993 1","pages":"1330-1333 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"NO/sub x/ and SO/sub 2/ removal by pulsed power at a thermal power plant\",\"authors\":\"S. Tsukamoto, T. Namihira, D. Wang, S. Katsuki, H. Akiyama, E. Nakashima, A. Sato, Y. Uchida, M. Koike\",\"doi\":\"10.1109/PPC.1999.823772\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently various methods involving gas discharges and electron beams have been studied for the removal of NO/sub x/ and SO/sub 2/ from flue gases. The recent development of repetitive pulsed power generators gives the pulsed streamer corona discharges a chance of success in the removal of NO/sub x/ and SO/sub 2/. Experiments for the removal of NO/sub x/ and SO/sub 2/ using actual flue gases were performed at a thermal power plant. The results showed that about 90% of NO and about 50% of SO/sub 2/ were removed at a flow rate of 0.8 l/min and a repetition rate of 7 pulses per second (pps). The removal ratio of NO varied inversely proportional to the gas flow rate. The energy efficiency of NO removal was 900 /spl mu/mol/Wh when 50% of NO was removed.\",\"PeriodicalId\":11209,\"journal\":{\"name\":\"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)\",\"volume\":\"1993 1\",\"pages\":\"1330-1333 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPC.1999.823772\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1999.823772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

近年来,人们研究了各种气体放电和电子束法去除烟气中的NO/ subx /和SO/ sub2 /的方法。重复脉冲发电机的最新发展使脉冲流光电晕放电在去除NO/sub x/和SO/sub 2/方面有了成功的机会。在火力发电厂进行了利用实际烟气去除NO/sub x/和SO/sub 2/的实验。结果表明,在流速为0.8 l/min、重复次数为7脉冲/秒(pps)的条件下,NO去除率约为90%,SO/sub 2/去除率约为50%。NO去除率与气体流速成反比。当NO去除率为50%时,NO去除率为900 /spl mu/mol/Wh。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
NO/sub x/ and SO/sub 2/ removal by pulsed power at a thermal power plant
Recently various methods involving gas discharges and electron beams have been studied for the removal of NO/sub x/ and SO/sub 2/ from flue gases. The recent development of repetitive pulsed power generators gives the pulsed streamer corona discharges a chance of success in the removal of NO/sub x/ and SO/sub 2/. Experiments for the removal of NO/sub x/ and SO/sub 2/ using actual flue gases were performed at a thermal power plant. The results showed that about 90% of NO and about 50% of SO/sub 2/ were removed at a flow rate of 0.8 l/min and a repetition rate of 7 pulses per second (pps). The removal ratio of NO varied inversely proportional to the gas flow rate. The energy efficiency of NO removal was 900 /spl mu/mol/Wh when 50% of NO was removed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信