{"title":"等离子体活化玻璃与硅的低温熔接","authors":"Ya-Huei Erica Chang, Dih-Yang Andy Kuo, Jhih Wei Gwako Liang, K. Yamazaki, Jay Zhang, Hitoshi Sakoda, Norio Kamitsubo","doi":"10.1109/IMPACT56280.2022.9966706","DOIUrl":null,"url":null,"abstract":"Anodic bonding has been extensively used to permanently bond glass to silicon (Si) wafer for MEMS (microelectromechanical systems)-based sensor applications. This approach involves the alkali ion migration (such as Li, Na, and K) under high-temperature, high pressure, and high voltage. Moreover, similar coefficients of thermal expansion (CTE) are required to bond these two heterogeneous substrates over a wide range of temperatures. However, some active or passive devices in MEMS are temperature sensitive and those alkali ions from glass could exhibit undesirable side effects to degrade the device performance when subjected to moisture and heat. The low-temperature direct bonding processes for an alkali-free glass wafer to another Si wafer hence has been studied recently.","PeriodicalId":13517,"journal":{"name":"Impact","volume":"77 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Low Temperature Fusion Bonding of Glass to Si Using Plasma Activation\",\"authors\":\"Ya-Huei Erica Chang, Dih-Yang Andy Kuo, Jhih Wei Gwako Liang, K. Yamazaki, Jay Zhang, Hitoshi Sakoda, Norio Kamitsubo\",\"doi\":\"10.1109/IMPACT56280.2022.9966706\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Anodic bonding has been extensively used to permanently bond glass to silicon (Si) wafer for MEMS (microelectromechanical systems)-based sensor applications. This approach involves the alkali ion migration (such as Li, Na, and K) under high-temperature, high pressure, and high voltage. Moreover, similar coefficients of thermal expansion (CTE) are required to bond these two heterogeneous substrates over a wide range of temperatures. However, some active or passive devices in MEMS are temperature sensitive and those alkali ions from glass could exhibit undesirable side effects to degrade the device performance when subjected to moisture and heat. The low-temperature direct bonding processes for an alkali-free glass wafer to another Si wafer hence has been studied recently.\",\"PeriodicalId\":13517,\"journal\":{\"name\":\"Impact\",\"volume\":\"77 1\",\"pages\":\"1-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Impact\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMPACT56280.2022.9966706\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Impact","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMPACT56280.2022.9966706","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

阳极键合已广泛应用于基于MEMS(微机电系统)传感器的玻璃与硅(Si)晶圆的永久键合。该方法涉及碱离子(如Li、Na、K)在高温、高压、高压下的迁移。此外,需要相似的热膨胀系数(CTE)来结合这两种非均质衬底在很宽的温度范围内。然而,MEMS中的一些有源或无源器件对温度敏感,玻璃中的碱离子在受潮和受热时可能会表现出不良的副作用,从而降低器件性能。因此,对无碱玻璃晶片与硅晶片的低温直接键合工艺进行了研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Low Temperature Fusion Bonding of Glass to Si Using Plasma Activation
Anodic bonding has been extensively used to permanently bond glass to silicon (Si) wafer for MEMS (microelectromechanical systems)-based sensor applications. This approach involves the alkali ion migration (such as Li, Na, and K) under high-temperature, high pressure, and high voltage. Moreover, similar coefficients of thermal expansion (CTE) are required to bond these two heterogeneous substrates over a wide range of temperatures. However, some active or passive devices in MEMS are temperature sensitive and those alkali ions from glass could exhibit undesirable side effects to degrade the device performance when subjected to moisture and heat. The low-temperature direct bonding processes for an alkali-free glass wafer to another Si wafer hence has been studied recently.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信