{"title":"气雾介质中雾的形成对击穿的影响","authors":"S. Yajima, M. Sone, H. Mitsui, S. Hirabayashi","doi":"10.1109/CEIDP.1989.69592","DOIUrl":null,"url":null,"abstract":"Experimental measurements of the effect of mist formation in vapor-mist dielectrics on impulse breakdown are presented. The water breakdown voltages are shown to increase as the temperature falls to the boiling point. This is an effect of the mist formation. The mist formation is also shown for benzene, hexane, ethyl alcohol, methyl alcohol, Freon R-11, R-113, R-11-R-113 mixture, R-113-R-114 mixture, and R-113-R-12 mixture mist. The electrical strength of the mist depends on the mass increase of clusters.<<ETX>>","PeriodicalId":10719,"journal":{"name":"Conference on Electrical Insulation and Dielectric Phenomena,","volume":"77 1","pages":"477-482"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Effect of mist formation in vapor-mist dielectrics on breakdown\",\"authors\":\"S. Yajima, M. Sone, H. Mitsui, S. Hirabayashi\",\"doi\":\"10.1109/CEIDP.1989.69592\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Experimental measurements of the effect of mist formation in vapor-mist dielectrics on impulse breakdown are presented. The water breakdown voltages are shown to increase as the temperature falls to the boiling point. This is an effect of the mist formation. The mist formation is also shown for benzene, hexane, ethyl alcohol, methyl alcohol, Freon R-11, R-113, R-11-R-113 mixture, R-113-R-114 mixture, and R-113-R-12 mixture mist. The electrical strength of the mist depends on the mass increase of clusters.<<ETX>>\",\"PeriodicalId\":10719,\"journal\":{\"name\":\"Conference on Electrical Insulation and Dielectric Phenomena,\",\"volume\":\"77 1\",\"pages\":\"477-482\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference on Electrical Insulation and Dielectric Phenomena,\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1989.69592\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation and Dielectric Phenomena,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1989.69592","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
介绍了气雾介质中雾的形成对脉冲击穿影响的实验测量结果。当温度降至沸点时,水的击穿电压增加。这是雾形成的结果。还显示了苯、己烷、乙醇、甲醇、氟利昂R-11、R-113、R-11-R-113混合物、R-113- r -114混合物和R-113- r -12混合物雾的形成。雾的电强度取决于团簇质量的增加。
Effect of mist formation in vapor-mist dielectrics on breakdown
Experimental measurements of the effect of mist formation in vapor-mist dielectrics on impulse breakdown are presented. The water breakdown voltages are shown to increase as the temperature falls to the boiling point. This is an effect of the mist formation. The mist formation is also shown for benzene, hexane, ethyl alcohol, methyl alcohol, Freon R-11, R-113, R-11-R-113 mixture, R-113-R-114 mixture, and R-113-R-12 mixture mist. The electrical strength of the mist depends on the mass increase of clusters.<>