{"title":"验证了联合片剂中阿米洛利和氢氯噻嗪含量的反相高效液相色谱法","authors":"R. Kumar, G. R. Babu, M. Sowjanya, M. Ramayyappa","doi":"10.52711/2231-5675.2021.00037","DOIUrl":null,"url":null,"abstract":"The aim of this work is to build up a fast, exact, precise and touchy reverse phase liquid chromatographic method for the synchronous assessment of amiloride and hydrochlorothiazide in tablet dose structure. The chromatographic strategy was normalized utilizing Hypersil ODS segment (250×4.6mm, 5μm molecule size) with UV discovery at 210nm and stream pace of 1ml/min. The portable stage includes phosphate buffer (pH acclimated to 2.5 with dilute Ortho Phosphoric acid) and acetonitrile in the proportion of 60:40 v/v. The linearity of proposed technique was examined in the scope of 5-30μg/ml (R²=0.999) for amiloride and 50-300μg/ml (R²=0.999) for Hydrochlorothiazide appropriately. The limit of detection (LOD) was discovered to be 0.10μg/ml and 0.40μg/ml for Amiloride and Hydrochlorothiazide appropriately. The limit of quantitation (LOQ) was discovered to be 0.30μg/ml and 1.20μg/ml for Amiloride and Hydrochlorothiazide separately. The retention times of Amiloride and Hydrochlorothiazide were found to be 3.258min and 2.383min separately. The technique was truly recommended and %RSD was found to be under 2 demonstrating serious level of exactness and accuracy. Subsequently proposed strategy can be effectively evaluated for the synchronous assessment of Amiloride and Hydrochlorothiazide in promoted formulations.","PeriodicalId":8547,"journal":{"name":"Asian Journal of Pharmaceutical Analysis","volume":"7 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Validated RP-HPLC method for the estimation of Amiloride and hydrochlorothiazide in combined tablet dosage form\",\"authors\":\"R. Kumar, G. R. Babu, M. Sowjanya, M. Ramayyappa\",\"doi\":\"10.52711/2231-5675.2021.00037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this work is to build up a fast, exact, precise and touchy reverse phase liquid chromatographic method for the synchronous assessment of amiloride and hydrochlorothiazide in tablet dose structure. The chromatographic strategy was normalized utilizing Hypersil ODS segment (250×4.6mm, 5μm molecule size) with UV discovery at 210nm and stream pace of 1ml/min. The portable stage includes phosphate buffer (pH acclimated to 2.5 with dilute Ortho Phosphoric acid) and acetonitrile in the proportion of 60:40 v/v. The linearity of proposed technique was examined in the scope of 5-30μg/ml (R²=0.999) for amiloride and 50-300μg/ml (R²=0.999) for Hydrochlorothiazide appropriately. The limit of detection (LOD) was discovered to be 0.10μg/ml and 0.40μg/ml for Amiloride and Hydrochlorothiazide appropriately. The limit of quantitation (LOQ) was discovered to be 0.30μg/ml and 1.20μg/ml for Amiloride and Hydrochlorothiazide separately. The retention times of Amiloride and Hydrochlorothiazide were found to be 3.258min and 2.383min separately. The technique was truly recommended and %RSD was found to be under 2 demonstrating serious level of exactness and accuracy. Subsequently proposed strategy can be effectively evaluated for the synchronous assessment of Amiloride and Hydrochlorothiazide in promoted formulations.\",\"PeriodicalId\":8547,\"journal\":{\"name\":\"Asian Journal of Pharmaceutical Analysis\",\"volume\":\"7 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Pharmaceutical Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52711/2231-5675.2021.00037\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Pharmaceutical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52711/2231-5675.2021.00037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Validated RP-HPLC method for the estimation of Amiloride and hydrochlorothiazide in combined tablet dosage form
The aim of this work is to build up a fast, exact, precise and touchy reverse phase liquid chromatographic method for the synchronous assessment of amiloride and hydrochlorothiazide in tablet dose structure. The chromatographic strategy was normalized utilizing Hypersil ODS segment (250×4.6mm, 5μm molecule size) with UV discovery at 210nm and stream pace of 1ml/min. The portable stage includes phosphate buffer (pH acclimated to 2.5 with dilute Ortho Phosphoric acid) and acetonitrile in the proportion of 60:40 v/v. The linearity of proposed technique was examined in the scope of 5-30μg/ml (R²=0.999) for amiloride and 50-300μg/ml (R²=0.999) for Hydrochlorothiazide appropriately. The limit of detection (LOD) was discovered to be 0.10μg/ml and 0.40μg/ml for Amiloride and Hydrochlorothiazide appropriately. The limit of quantitation (LOQ) was discovered to be 0.30μg/ml and 1.20μg/ml for Amiloride and Hydrochlorothiazide separately. The retention times of Amiloride and Hydrochlorothiazide were found to be 3.258min and 2.383min separately. The technique was truly recommended and %RSD was found to be under 2 demonstrating serious level of exactness and accuracy. Subsequently proposed strategy can be effectively evaluated for the synchronous assessment of Amiloride and Hydrochlorothiazide in promoted formulations.