{"title":"罗素广场剧院报道","authors":"Di Yang","doi":"10.56397/ist.2022.10.03","DOIUrl":null,"url":null,"abstract":"Design of a low-energy, passively ventilated, healthy and comfortable theatre building for Russell Square in the London area. The project utilizes analytical tools—IES VE and CIBS EAM10—to assist in the design of building performance simulations and to analyze and test the effectiveness of building and environmental strategies. The project maximizes the natural ventilation and passive cooling of the theatre, and the building performance simulation is iterated over time to achieve the required environmental objectives for the building’s volume flow and CO2 concentration. The building was optimized through the use of solar energy, natural wind and geographical topography, high performance building maintenance structures and good airtightness and shading adjustable technologies to enhance the use of passive technologies, ultimately providing a quality building that meets the project objectives of health and comfort.","PeriodicalId":20688,"journal":{"name":"Proceedings of The 6th International Conference on Innovation in Science and Technology","volume":"39 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Report of the Russell Square Theatre\",\"authors\":\"Di Yang\",\"doi\":\"10.56397/ist.2022.10.03\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Design of a low-energy, passively ventilated, healthy and comfortable theatre building for Russell Square in the London area. The project utilizes analytical tools—IES VE and CIBS EAM10—to assist in the design of building performance simulations and to analyze and test the effectiveness of building and environmental strategies. The project maximizes the natural ventilation and passive cooling of the theatre, and the building performance simulation is iterated over time to achieve the required environmental objectives for the building’s volume flow and CO2 concentration. The building was optimized through the use of solar energy, natural wind and geographical topography, high performance building maintenance structures and good airtightness and shading adjustable technologies to enhance the use of passive technologies, ultimately providing a quality building that meets the project objectives of health and comfort.\",\"PeriodicalId\":20688,\"journal\":{\"name\":\"Proceedings of The 6th International Conference on Innovation in Science and Technology\",\"volume\":\"39 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of The 6th International Conference on Innovation in Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.56397/ist.2022.10.03\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of The 6th International Conference on Innovation in Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56397/ist.2022.10.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为伦敦罗素广场设计一座低能耗、被动通风、健康舒适的剧院建筑。该项目利用分析工具(ies VE和CIBS eam10)协助设计建筑性能模拟,并分析和测试建筑和环境战略的有效性。该项目最大限度地利用了剧院的自然通风和被动冷却,随着时间的推移,建筑性能模拟不断迭代,以实现建筑体积流量和二氧化碳浓度所需的环境目标。该建筑通过利用太阳能、自然风和地理地形、高性能建筑维护结构和良好的气密性和遮阳调节技术来优化,以加强被动技术的使用,最终提供了一个满足健康和舒适项目目标的高质量建筑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Report of the Russell Square Theatre
Design of a low-energy, passively ventilated, healthy and comfortable theatre building for Russell Square in the London area. The project utilizes analytical tools—IES VE and CIBS EAM10—to assist in the design of building performance simulations and to analyze and test the effectiveness of building and environmental strategies. The project maximizes the natural ventilation and passive cooling of the theatre, and the building performance simulation is iterated over time to achieve the required environmental objectives for the building’s volume flow and CO2 concentration. The building was optimized through the use of solar energy, natural wind and geographical topography, high performance building maintenance structures and good airtightness and shading adjustable technologies to enhance the use of passive technologies, ultimately providing a quality building that meets the project objectives of health and comfort.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信