{"title":"在短路径长度处测定光束衰减系数的原位校准","authors":"R. Prien","doi":"10.1109/OCEANS.2000.881802","DOIUrl":null,"url":null,"abstract":"A laboratory model of a short pathlength transmissometer with an in situ calibration facility was built to demonstrate the feasibility of high precision attenuation coefficient measurements at short pathlength even in clear waters. The high precision is enabled by the in situ calibration by variation of pathlength which is needed to overcome errors introduced by various sources such as window staining due to biofouling, multiple reflections at the glass-water interfaces and changes in refractive index of the medium. The laboratory model consists of a narrow bandwidth light source (LED) with a peak wavelength of 650 nm and beamforming optics, a moveable prism for retroreflection of the probe beam and receiving optics with a PIN-photodiode detector and transimpedance amplifier. With this setup a short term precision of the order of 10/sup -4/ m/sup -1/ was achieved at a constant pathlength of 54.7 mm. Drifts on longer terms, including staining of the instrument windows, can be compensated by the in situ calibration which showed a repeatability in the order of 10/sup -3/ m/sup -1/.","PeriodicalId":68534,"journal":{"name":"中国会展","volume":"1 1","pages":"1413-1419 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"2000-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In situ calibration for beam attenuation coefficient determination at short pathlengths\",\"authors\":\"R. Prien\",\"doi\":\"10.1109/OCEANS.2000.881802\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A laboratory model of a short pathlength transmissometer with an in situ calibration facility was built to demonstrate the feasibility of high precision attenuation coefficient measurements at short pathlength even in clear waters. The high precision is enabled by the in situ calibration by variation of pathlength which is needed to overcome errors introduced by various sources such as window staining due to biofouling, multiple reflections at the glass-water interfaces and changes in refractive index of the medium. The laboratory model consists of a narrow bandwidth light source (LED) with a peak wavelength of 650 nm and beamforming optics, a moveable prism for retroreflection of the probe beam and receiving optics with a PIN-photodiode detector and transimpedance amplifier. With this setup a short term precision of the order of 10/sup -4/ m/sup -1/ was achieved at a constant pathlength of 54.7 mm. Drifts on longer terms, including staining of the instrument windows, can be compensated by the in situ calibration which showed a repeatability in the order of 10/sup -3/ m/sup -1/.\",\"PeriodicalId\":68534,\"journal\":{\"name\":\"中国会展\",\"volume\":\"1 1\",\"pages\":\"1413-1419 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-09-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国会展\",\"FirstCategoryId\":\"96\",\"ListUrlMain\":\"https://doi.org/10.1109/OCEANS.2000.881802\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国会展","FirstCategoryId":"96","ListUrlMain":"https://doi.org/10.1109/OCEANS.2000.881802","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

建立了带现场标定装置的短径透射仪实验室模型,验证了在清水条件下高精度测量短径衰减系数的可行性。通过改变路径长度的原位校准,可以实现高精度,这需要克服各种来源带来的误差,例如由于生物污垢引起的窗口染色,玻璃-水界面的多次反射和介质折射率的变化。该实验室模型由峰值波长为650 nm的窄带宽光源(LED)和波束形成光学元件、用于探头光束反向反射的可移动棱镜和带有pin光电二极管检测器和透阻放大器的接收光学元件组成。通过这种设置,在54.7 mm的恒定路径长度下实现了10/sup -4/ m/sup -1/的短期精度。长期的漂移,包括仪器窗口的染色,可以通过原位校准来补偿,其重复性为10/sup -3/ m/sup -1/。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In situ calibration for beam attenuation coefficient determination at short pathlengths
A laboratory model of a short pathlength transmissometer with an in situ calibration facility was built to demonstrate the feasibility of high precision attenuation coefficient measurements at short pathlength even in clear waters. The high precision is enabled by the in situ calibration by variation of pathlength which is needed to overcome errors introduced by various sources such as window staining due to biofouling, multiple reflections at the glass-water interfaces and changes in refractive index of the medium. The laboratory model consists of a narrow bandwidth light source (LED) with a peak wavelength of 650 nm and beamforming optics, a moveable prism for retroreflection of the probe beam and receiving optics with a PIN-photodiode detector and transimpedance amplifier. With this setup a short term precision of the order of 10/sup -4/ m/sup -1/ was achieved at a constant pathlength of 54.7 mm. Drifts on longer terms, including staining of the instrument windows, can be compensated by the in situ calibration which showed a repeatability in the order of 10/sup -3/ m/sup -1/.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
8254
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信