超声心动图提高左心室射血分数评价的质量

A. Johri, Matthew I Crerar, A. Sanfilippo
{"title":"超声心动图提高左心室射血分数评价的质量","authors":"A. Johri, Matthew I Crerar, A. Sanfilippo","doi":"10.15420/USC.2012.9.2.105","DOIUrl":null,"url":null,"abstract":"IOV in the assessment of LVEF. Galema et al. showed that, in a cohort of patients who had recently undergone primary angioplasty for the treatment of acute myocardial infarction, both intra-observer variability and IOV in the assessment of LVEF were significantly reduced after left ventricular (LV) opacification through the administration of a bolus of contrast agent. 1 Comparison with the mean LVEF results of experienced cardiologists demonstrated that Abstract The assessment of left ventricular ejection fraction is a key clinical investigation guiding the diagnosis, management and prognosis of cardiology patients. Echocardiography is an inexpensive, safe, and portable method commonly used to provide this information. Improvement in the quality of assessment provided by echocardiography continues to be the subject of current clinical programs and investigations. Contrast-enhanced echocardiography is an established method to reduce both inter- and intra-observer variability in the echocardiography lab. The implementation of teaching interventions has also been shown to reduce variability in the qualitative and quantitative assessment of ejection fraction. Newer investigative methods, such as 3D imaging and speckle tracking, show promise as tools to further enhance the quality of left ventricular ejection fraction assessment in the echocardiography lab.","PeriodicalId":74859,"journal":{"name":"Spring simulation conference (SpringSim)","volume":"1 1","pages":"105-107"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enhancing the Quality of Left Ventricular Ejection Fraction Assessment by Echocardiography\",\"authors\":\"A. Johri, Matthew I Crerar, A. Sanfilippo\",\"doi\":\"10.15420/USC.2012.9.2.105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"IOV in the assessment of LVEF. Galema et al. showed that, in a cohort of patients who had recently undergone primary angioplasty for the treatment of acute myocardial infarction, both intra-observer variability and IOV in the assessment of LVEF were significantly reduced after left ventricular (LV) opacification through the administration of a bolus of contrast agent. 1 Comparison with the mean LVEF results of experienced cardiologists demonstrated that Abstract The assessment of left ventricular ejection fraction is a key clinical investigation guiding the diagnosis, management and prognosis of cardiology patients. Echocardiography is an inexpensive, safe, and portable method commonly used to provide this information. Improvement in the quality of assessment provided by echocardiography continues to be the subject of current clinical programs and investigations. Contrast-enhanced echocardiography is an established method to reduce both inter- and intra-observer variability in the echocardiography lab. The implementation of teaching interventions has also been shown to reduce variability in the qualitative and quantitative assessment of ejection fraction. Newer investigative methods, such as 3D imaging and speckle tracking, show promise as tools to further enhance the quality of left ventricular ejection fraction assessment in the echocardiography lab.\",\"PeriodicalId\":74859,\"journal\":{\"name\":\"Spring simulation conference (SpringSim)\",\"volume\":\"1 1\",\"pages\":\"105-107\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spring simulation conference (SpringSim)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15420/USC.2012.9.2.105\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spring simulation conference (SpringSim)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15420/USC.2012.9.2.105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

LVEF评估中的IOV。Galema等人的研究表明,在一组近期接受初级血管成形术治疗急性心肌梗死的患者中,通过给药造影剂进行左室(LV)混浊后,评估LVEF的观察者内变异性和IOV均显著降低。摘要左室射血分数的评估是指导心脏病患者诊断、治疗和预后的关键临床指标。超声心动图是一种廉价、安全、便携的方法,通常用于提供这些信息。改善超声心动图提供的评估质量仍然是当前临床项目和调查的主题。对比增强超声心动图是一种既定的方法,以减少在超声心动图实验室的观察者之间和内部的可变性。教学干预的实施也被证明可以减少射血分数定性和定量评估的可变性。较新的研究方法,如3D成像和斑点跟踪,显示出作为进一步提高超声心动图实验室左心室射血分数评估质量的工具的希望。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enhancing the Quality of Left Ventricular Ejection Fraction Assessment by Echocardiography
IOV in the assessment of LVEF. Galema et al. showed that, in a cohort of patients who had recently undergone primary angioplasty for the treatment of acute myocardial infarction, both intra-observer variability and IOV in the assessment of LVEF were significantly reduced after left ventricular (LV) opacification through the administration of a bolus of contrast agent. 1 Comparison with the mean LVEF results of experienced cardiologists demonstrated that Abstract The assessment of left ventricular ejection fraction is a key clinical investigation guiding the diagnosis, management and prognosis of cardiology patients. Echocardiography is an inexpensive, safe, and portable method commonly used to provide this information. Improvement in the quality of assessment provided by echocardiography continues to be the subject of current clinical programs and investigations. Contrast-enhanced echocardiography is an established method to reduce both inter- and intra-observer variability in the echocardiography lab. The implementation of teaching interventions has also been shown to reduce variability in the qualitative and quantitative assessment of ejection fraction. Newer investigative methods, such as 3D imaging and speckle tracking, show promise as tools to further enhance the quality of left ventricular ejection fraction assessment in the echocardiography lab.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信