A. Ricapito, Matteo Rubino, P. Annese, V. Mancini, U. Falagario, L. Cormio, G. Carrieri, G. Busetto, C. Bettocchi
{"title":"人工括约肌在男性压力性尿失禁中的应用:目前进展如何?叙述性回顾","authors":"A. Ricapito, Matteo Rubino, P. Annese, V. Mancini, U. Falagario, L. Cormio, G. Carrieri, G. Busetto, C. Bettocchi","doi":"10.3390/uro3030023","DOIUrl":null,"url":null,"abstract":"Introduction: Urinary incontinence is a prevalent condition, especially in elderly men, with stress urinary incontinence (SUI) being a common cause after radical prostatectomy. The artificial urinary sphincter (AUS), particularly the AMS 800™ device, has been the gold-standard treatment for moderate-severe male SUI for decades. Despite some technical advancements and alternative devices like ZSI-375, Victo, and BR-SL-AS 904 being introduced, there is limited literature comparing their effectiveness to the AMS 800™. Methods: This literature review compares the AMS 800™ to the newer technologies in the management of SUI. We reviewed the current literature on urinary sphincter implant in male stress incontinence, including AMS 800™, ZSI-375, Victo, and BR-SL-AS 904. Findings: The AMS 800™ is a sophisticated system consisting of an inflatable cuff, a pressure-regulating balloon, and a control pump. Studies show continence rates ranging from 61% to 100% with AMS 800™ implants, with low infection rates and significant improvement in patients’ quality of life. The ZSI-375 sphincter is a unique single-piece cuff without an abdominal reservoir, simplifying implantation. Preliminary data show a social continence rate of 73% at six months, with lower complication rates than the AMS 800™. The VICTO® device offers adjustable pressure and a stress relief mechanism, providing conditional occlusion of the urethra. Early studies report a satisfaction rate of up to 94.2% and a complication rate of 17.6%. BR-SL-AS 904 is a newly proposed urinary sphincter, but due to the limited number of cases and a single study, its efficacy and complication rates remain uncertain. Conclusions: Overall, AMS 800™ remains the gold-standard treatment for SUI after radical prostatectomy. Alternative devices like ZSI-375 and VICTO® show promising results, but longer studies and more data are needed to establish their effectiveness and safety compared with the AMS 800™. Further research and ongoing monitoring are essential to address mechanical issues associated with AUS implants.","PeriodicalId":44555,"journal":{"name":"Trudy Instituta Matematiki i Mekhaniki UrO RAN","volume":"2 1","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Urinary Artificial Sphincter in Male Stress Urinary Incontinence: Where Are We Today? A Narrative Review\",\"authors\":\"A. Ricapito, Matteo Rubino, P. Annese, V. Mancini, U. Falagario, L. Cormio, G. Carrieri, G. Busetto, C. Bettocchi\",\"doi\":\"10.3390/uro3030023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Urinary incontinence is a prevalent condition, especially in elderly men, with stress urinary incontinence (SUI) being a common cause after radical prostatectomy. The artificial urinary sphincter (AUS), particularly the AMS 800™ device, has been the gold-standard treatment for moderate-severe male SUI for decades. Despite some technical advancements and alternative devices like ZSI-375, Victo, and BR-SL-AS 904 being introduced, there is limited literature comparing their effectiveness to the AMS 800™. Methods: This literature review compares the AMS 800™ to the newer technologies in the management of SUI. We reviewed the current literature on urinary sphincter implant in male stress incontinence, including AMS 800™, ZSI-375, Victo, and BR-SL-AS 904. Findings: The AMS 800™ is a sophisticated system consisting of an inflatable cuff, a pressure-regulating balloon, and a control pump. Studies show continence rates ranging from 61% to 100% with AMS 800™ implants, with low infection rates and significant improvement in patients’ quality of life. The ZSI-375 sphincter is a unique single-piece cuff without an abdominal reservoir, simplifying implantation. Preliminary data show a social continence rate of 73% at six months, with lower complication rates than the AMS 800™. The VICTO® device offers adjustable pressure and a stress relief mechanism, providing conditional occlusion of the urethra. Early studies report a satisfaction rate of up to 94.2% and a complication rate of 17.6%. BR-SL-AS 904 is a newly proposed urinary sphincter, but due to the limited number of cases and a single study, its efficacy and complication rates remain uncertain. Conclusions: Overall, AMS 800™ remains the gold-standard treatment for SUI after radical prostatectomy. Alternative devices like ZSI-375 and VICTO® show promising results, but longer studies and more data are needed to establish their effectiveness and safety compared with the AMS 800™. Further research and ongoing monitoring are essential to address mechanical issues associated with AUS implants.\",\"PeriodicalId\":44555,\"journal\":{\"name\":\"Trudy Instituta Matematiki i Mekhaniki UrO RAN\",\"volume\":\"2 1\",\"pages\":\"\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2023-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trudy Instituta Matematiki i Mekhaniki UrO RAN\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/uro3030023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATHEMATICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trudy Instituta Matematiki i Mekhaniki UrO RAN","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/uro3030023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATHEMATICS, APPLIED","Score":null,"Total":0}
Urinary Artificial Sphincter in Male Stress Urinary Incontinence: Where Are We Today? A Narrative Review
Introduction: Urinary incontinence is a prevalent condition, especially in elderly men, with stress urinary incontinence (SUI) being a common cause after radical prostatectomy. The artificial urinary sphincter (AUS), particularly the AMS 800™ device, has been the gold-standard treatment for moderate-severe male SUI for decades. Despite some technical advancements and alternative devices like ZSI-375, Victo, and BR-SL-AS 904 being introduced, there is limited literature comparing their effectiveness to the AMS 800™. Methods: This literature review compares the AMS 800™ to the newer technologies in the management of SUI. We reviewed the current literature on urinary sphincter implant in male stress incontinence, including AMS 800™, ZSI-375, Victo, and BR-SL-AS 904. Findings: The AMS 800™ is a sophisticated system consisting of an inflatable cuff, a pressure-regulating balloon, and a control pump. Studies show continence rates ranging from 61% to 100% with AMS 800™ implants, with low infection rates and significant improvement in patients’ quality of life. The ZSI-375 sphincter is a unique single-piece cuff without an abdominal reservoir, simplifying implantation. Preliminary data show a social continence rate of 73% at six months, with lower complication rates than the AMS 800™. The VICTO® device offers adjustable pressure and a stress relief mechanism, providing conditional occlusion of the urethra. Early studies report a satisfaction rate of up to 94.2% and a complication rate of 17.6%. BR-SL-AS 904 is a newly proposed urinary sphincter, but due to the limited number of cases and a single study, its efficacy and complication rates remain uncertain. Conclusions: Overall, AMS 800™ remains the gold-standard treatment for SUI after radical prostatectomy. Alternative devices like ZSI-375 and VICTO® show promising results, but longer studies and more data are needed to establish their effectiveness and safety compared with the AMS 800™. Further research and ongoing monitoring are essential to address mechanical issues associated with AUS implants.