最小二乘支持向量机鲁棒分光光度法同时测定抗糖尿病药物并与色谱法比较

IF 1 Q4 CHEMISTRY, MULTIDISCIPLINARY
Vale Arabzadeh, M. Sohrabi, N. Goudarzi, M. Davallo
{"title":"最小二乘支持向量机鲁棒分光光度法同时测定抗糖尿病药物并与色谱法比较","authors":"Vale Arabzadeh, M. Sohrabi, N. Goudarzi, M. Davallo","doi":"10.22052/IJMC.2020.212363.1477","DOIUrl":null,"url":null,"abstract":"In the present paper, the simultaneous spectrophotometric estimation of Metformin (MET) and Pioglitazone (PIO) in an antidiabetic drug called Actoplus MET based on least squares support vector machine (LS-SVM) was proposed. The optimum gamma (γ) and sigma (σ) parameters were found to be 825 and 90 with the root mean square error (RMSE) of 0.1343for MET, as well as 1000 and 350 with RMSE=0.4120 for PIO. Also, the mean recovery values of MET and PIO were 99.81% and 100.19%, respectively. Ultimately, the real sample was analyzed by High-Performance Liquid Chromatography (HPLC) reference method and the proposed procedure. Then, one-way analysis of variance (ANOVA) test at the 95 % confidence level was performed on achieved results from HPLC and LS-SVM methods. The statistical data of these methods showed that there were no significant differences between them.","PeriodicalId":14545,"journal":{"name":"Iranian journal of mathematical chemistry","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Robust Spectrophotometric Method using Least Squares Support Vector Machine for Simultaneous Determination of Anti−Diabetic Drugs and Comparison with the Chromatographic Method\",\"authors\":\"Vale Arabzadeh, M. Sohrabi, N. Goudarzi, M. Davallo\",\"doi\":\"10.22052/IJMC.2020.212363.1477\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present paper, the simultaneous spectrophotometric estimation of Metformin (MET) and Pioglitazone (PIO) in an antidiabetic drug called Actoplus MET based on least squares support vector machine (LS-SVM) was proposed. The optimum gamma (γ) and sigma (σ) parameters were found to be 825 and 90 with the root mean square error (RMSE) of 0.1343for MET, as well as 1000 and 350 with RMSE=0.4120 for PIO. Also, the mean recovery values of MET and PIO were 99.81% and 100.19%, respectively. Ultimately, the real sample was analyzed by High-Performance Liquid Chromatography (HPLC) reference method and the proposed procedure. Then, one-way analysis of variance (ANOVA) test at the 95 % confidence level was performed on achieved results from HPLC and LS-SVM methods. The statistical data of these methods showed that there were no significant differences between them.\",\"PeriodicalId\":14545,\"journal\":{\"name\":\"Iranian journal of mathematical chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2020-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian journal of mathematical chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22052/IJMC.2020.212363.1477\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian journal of mathematical chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22052/IJMC.2020.212363.1477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了基于最小二乘支持向量机(LS-SVM)的同时分光光度法测定降糖药Actoplus MET中二甲双胍(MET)和吡格列酮(PIO)的含量。MET的最佳gamma (γ)和sigma (σ)参数分别为825和90,均方根误差(RMSE)为0.1343;PIO的最佳gamma (γ)和σ (σ)参数分别为1000和350,RMSE=0.4120。MET和PIO的平均回收率分别为99.81%和100.19%。最后,采用高效液相色谱(HPLC)标准方法和所提方法对样品进行分析。然后对HPLC和LS-SVM方法获得的结果进行95%置信度的单因素方差分析(ANOVA)检验。两种方法的统计数据均无显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Robust Spectrophotometric Method using Least Squares Support Vector Machine for Simultaneous Determination of Anti−Diabetic Drugs and Comparison with the Chromatographic Method
In the present paper, the simultaneous spectrophotometric estimation of Metformin (MET) and Pioglitazone (PIO) in an antidiabetic drug called Actoplus MET based on least squares support vector machine (LS-SVM) was proposed. The optimum gamma (γ) and sigma (σ) parameters were found to be 825 and 90 with the root mean square error (RMSE) of 0.1343for MET, as well as 1000 and 350 with RMSE=0.4120 for PIO. Also, the mean recovery values of MET and PIO were 99.81% and 100.19%, respectively. Ultimately, the real sample was analyzed by High-Performance Liquid Chromatography (HPLC) reference method and the proposed procedure. Then, one-way analysis of variance (ANOVA) test at the 95 % confidence level was performed on achieved results from HPLC and LS-SVM methods. The statistical data of these methods showed that there were no significant differences between them.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Iranian journal of mathematical chemistry
Iranian journal of mathematical chemistry CHEMISTRY, MULTIDISCIPLINARY-
CiteScore
2.10
自引率
7.70%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信