{"title":"喷水灭火系统启动时舱内烟雾行为的研究——喷水灭火系统启动时烟羽流量的理论与有效性","authors":"Mitsuru Ota, J. Yamaguchi, Yuta Kuwana, Yoshihumi Ohmiya","doi":"10.3210/FST.26.551","DOIUrl":null,"url":null,"abstract":"In Japan, it is required by law to install a sprinkler system (hereafter, SP System) in accordance with the use of the building and its size. In general, the purpose of the SP System is to extinguish fires, and therefore most research reports are related to fire extinguishing. However, the influence of the SP system activation on the smoke layer has not yet been sufficiently assessed. It is difficult to quantify the extinguishing time for SP systems, and the prediction of the behavior of the flames and the smoke, which is restricted by the SP systems, is still in the process of preliminary research. In order to be able to apply the influence of fire extinguishing equipment on the smoke behavior to the performance design, the effects of the sprinkling system need to be quantified. The successful evaluation and application of the fire suppression effects would allow for a more rational assessment of the fire performance, which is currently evaluated by assuming the emergence of an uncontrolled fire. Consequently, this would result in greater flexibility with respect to fire prevention planning Therefore, this experimental study examined the influence on the smoke layer during sprinkling, in order to obtain information about smoke behavior during the SP system activation. In this paper, the changes occurring in the fire plume after sprinkling are reported.","PeriodicalId":12289,"journal":{"name":"Fire Science and Technology","volume":"9 1","pages":"551-556"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Study of Smoke Behavior in a Compartment with Sprinkler System Activation -Theory and Validity on the Flow Rate of the Fire Plume during Sprinkler System Activation-\",\"authors\":\"Mitsuru Ota, J. Yamaguchi, Yuta Kuwana, Yoshihumi Ohmiya\",\"doi\":\"10.3210/FST.26.551\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In Japan, it is required by law to install a sprinkler system (hereafter, SP System) in accordance with the use of the building and its size. In general, the purpose of the SP System is to extinguish fires, and therefore most research reports are related to fire extinguishing. However, the influence of the SP system activation on the smoke layer has not yet been sufficiently assessed. It is difficult to quantify the extinguishing time for SP systems, and the prediction of the behavior of the flames and the smoke, which is restricted by the SP systems, is still in the process of preliminary research. In order to be able to apply the influence of fire extinguishing equipment on the smoke behavior to the performance design, the effects of the sprinkling system need to be quantified. The successful evaluation and application of the fire suppression effects would allow for a more rational assessment of the fire performance, which is currently evaluated by assuming the emergence of an uncontrolled fire. Consequently, this would result in greater flexibility with respect to fire prevention planning Therefore, this experimental study examined the influence on the smoke layer during sprinkling, in order to obtain information about smoke behavior during the SP system activation. In this paper, the changes occurring in the fire plume after sprinkling are reported.\",\"PeriodicalId\":12289,\"journal\":{\"name\":\"Fire Science and Technology\",\"volume\":\"9 1\",\"pages\":\"551-556\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Science and Technology\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://doi.org/10.3210/FST.26.551\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Science and Technology","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3210/FST.26.551","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在日本,法律要求根据建筑物的用途和大小安装喷水灭火系统(以下简称SP系统)。一般来说,SP系统的目的是灭火,因此大多数研究报告都与灭火有关。然而,SP系统活化对烟层的影响尚未得到充分的评估。喷雾灭火系统的灭火时间难以量化,对火焰和烟雾行为的预测也受到喷雾灭火系统的限制,目前还处于初步研究阶段。为了能够将灭火设备对烟雾行为的影响应用到性能设计中,需要对喷淋系统的效果进行量化。灭火效果的成功评估和应用将允许对消防性能进行更合理的评估,目前通过假设出现不受控制的火灾来评估消防性能。因此,这将在防火规划方面带来更大的灵活性。因此,本实验研究考察了喷洒过程中对烟雾层的影响,以获得SP系统激活过程中烟雾行为的信息。本文报道了喷淋后火焰羽流的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Study of Smoke Behavior in a Compartment with Sprinkler System Activation -Theory and Validity on the Flow Rate of the Fire Plume during Sprinkler System Activation-
In Japan, it is required by law to install a sprinkler system (hereafter, SP System) in accordance with the use of the building and its size. In general, the purpose of the SP System is to extinguish fires, and therefore most research reports are related to fire extinguishing. However, the influence of the SP system activation on the smoke layer has not yet been sufficiently assessed. It is difficult to quantify the extinguishing time for SP systems, and the prediction of the behavior of the flames and the smoke, which is restricted by the SP systems, is still in the process of preliminary research. In order to be able to apply the influence of fire extinguishing equipment on the smoke behavior to the performance design, the effects of the sprinkling system need to be quantified. The successful evaluation and application of the fire suppression effects would allow for a more rational assessment of the fire performance, which is currently evaluated by assuming the emergence of an uncontrolled fire. Consequently, this would result in greater flexibility with respect to fire prevention planning Therefore, this experimental study examined the influence on the smoke layer during sprinkling, in order to obtain information about smoke behavior during the SP system activation. In this paper, the changes occurring in the fire plume after sprinkling are reported.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信