采用SOCA型眼晶状体剂量计检测Hp(3)剂量

A. T. Desviana, F. Adhisti, B. Bunawas
{"title":"采用SOCA型眼晶状体剂量计检测Hp(3)剂量","authors":"A. T. Desviana, F. Adhisti, B. Bunawas","doi":"10.1063/5.0061158","DOIUrl":null,"url":null,"abstract":"Interventional cardiology and radiology workers are exposed with occupational radiation. Radiation workers must use not only personal dosimeter; but also eye lens dosimeter in order to maintain the dose that does not exceed the dose limit value set by Nuclear Energy Regulatory Agency (Bapeten) which is 20 mSv a year with no single year exceeding 50 mSv. In order to provide a reliable with affordable price dosimeter, a new eye lens dosimeter was developed at NuklindoLab using TLD-900 (CaSO4:Dy) disc for measurement of dose in term of Hp(3). The type testing including homogeneity test, linearity of dose response, angular dependence test, and determining detection threshold were done after the irradiation carried out in Secondary Standard Dosimetry Laboratory (SSDL) Agensi Nuklear Malaysia. The method of the irradiation was based on ISO 4037-3 and the reference of the type testing was based on ISO 12794. The coefficient of variance (CV) value from homogeneity test results 4.8%, the linearity test result R2 values vary from 0.998 to 0.999, the angular dependence result ranges from 0% to 19% with average value 12.9%, and the detection threshold of SOCA dosimeter value was 0.35 mSv.","PeriodicalId":20561,"journal":{"name":"PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2020 (ISCPMS 2020)","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The SOCA type of eye lens dosimeter testing to measure Hp(3) dose\",\"authors\":\"A. T. Desviana, F. Adhisti, B. Bunawas\",\"doi\":\"10.1063/5.0061158\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Interventional cardiology and radiology workers are exposed with occupational radiation. Radiation workers must use not only personal dosimeter; but also eye lens dosimeter in order to maintain the dose that does not exceed the dose limit value set by Nuclear Energy Regulatory Agency (Bapeten) which is 20 mSv a year with no single year exceeding 50 mSv. In order to provide a reliable with affordable price dosimeter, a new eye lens dosimeter was developed at NuklindoLab using TLD-900 (CaSO4:Dy) disc for measurement of dose in term of Hp(3). The type testing including homogeneity test, linearity of dose response, angular dependence test, and determining detection threshold were done after the irradiation carried out in Secondary Standard Dosimetry Laboratory (SSDL) Agensi Nuklear Malaysia. The method of the irradiation was based on ISO 4037-3 and the reference of the type testing was based on ISO 12794. The coefficient of variance (CV) value from homogeneity test results 4.8%, the linearity test result R2 values vary from 0.998 to 0.999, the angular dependence result ranges from 0% to 19% with average value 12.9%, and the detection threshold of SOCA dosimeter value was 0.35 mSv.\",\"PeriodicalId\":20561,\"journal\":{\"name\":\"PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2020 (ISCPMS 2020)\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2020 (ISCPMS 2020)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0061158\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PROCEEDINGS OF THE 6TH INTERNATIONAL SYMPOSIUM ON CURRENT PROGRESS IN MATHEMATICS AND SCIENCES 2020 (ISCPMS 2020)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0061158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介入心脏病学和放射学工作者暴露在职业性辐射中。辐射工作人员不仅要使用个人剂量计;还有眼透镜剂量计,以保持剂量不超过核能监管机构(Bapeten)规定的剂量限值,即每年20毫西弗,没有一年超过50毫西弗。为了提供一种可靠且价格合理的剂量计,NuklindoLab开发了一种新的眼透镜剂量计,使用TLD-900 (CaSO4:Dy)光盘测量Hp(3)的剂量。辐照后在马来西亚原子能机构二级标准剂量测定实验室(SSDL)进行类型试验,包括均匀性试验、剂量响应线性、角依赖性试验和检测阈值的确定。辐照方法参照ISO 4037-3,型式试验参照ISO 12794。同质性检验结果的方差系数(CV)为4.8%,线性度检验结果R2为0.998 ~ 0.999,角依赖性结果为0% ~ 19%,平均值为12.9%,SOCA剂量计值的检测阈值为0.35 mSv。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The SOCA type of eye lens dosimeter testing to measure Hp(3) dose
Interventional cardiology and radiology workers are exposed with occupational radiation. Radiation workers must use not only personal dosimeter; but also eye lens dosimeter in order to maintain the dose that does not exceed the dose limit value set by Nuclear Energy Regulatory Agency (Bapeten) which is 20 mSv a year with no single year exceeding 50 mSv. In order to provide a reliable with affordable price dosimeter, a new eye lens dosimeter was developed at NuklindoLab using TLD-900 (CaSO4:Dy) disc for measurement of dose in term of Hp(3). The type testing including homogeneity test, linearity of dose response, angular dependence test, and determining detection threshold were done after the irradiation carried out in Secondary Standard Dosimetry Laboratory (SSDL) Agensi Nuklear Malaysia. The method of the irradiation was based on ISO 4037-3 and the reference of the type testing was based on ISO 12794. The coefficient of variance (CV) value from homogeneity test results 4.8%, the linearity test result R2 values vary from 0.998 to 0.999, the angular dependence result ranges from 0% to 19% with average value 12.9%, and the detection threshold of SOCA dosimeter value was 0.35 mSv.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信