J. Maenchen, S. Cordova, J. Gustwiller, D.L. Johnson, P. Menge, I. Molina, C. Olson, S. Rosenthal, D. Rovang, O. Oliver, D. Welch, V. Bailey, I. Smith, D. Droemer, E. Hunt, G. Macleod, L. Woo
{"title":"水动力射线照相用电感电压加法器驱动的x射线源","authors":"J. Maenchen, S. Cordova, J. Gustwiller, D.L. Johnson, P. Menge, I. Molina, C. Olson, S. Rosenthal, D. Rovang, O. Oliver, D. Welch, V. Bailey, I. Smith, D. Droemer, E. Hunt, G. Macleod, L. Woo","doi":"10.1109/PPC.1999.825465","DOIUrl":null,"url":null,"abstract":"Inductive voltage adder (IVA) accelerators were developed to provide high-current (100s of kA) power pulses at high voltage (up to 20 MV) using robust modular components. This architecture simultaneously resolves problems found in conventional pulsed and linear induction accelerators. A variety of high-brightness pulsed X-ray radiographic sources are needed from submegavolt to 16-MeV endpoints with greater source brightness (dose/spot/sup 2/) than presently available. We are applying IVA systems to produce very intense (up to 75 TW/cm/sup 2/) electron beams for these flash radiographic applications. The accelerator electromagnetic pulse is converted to a directed electron beam at the end of a self-magnetically insulated vacuum transmission line. The cantilevered cathode threading the accelerator cavities terminates in a small (l-mm diameter) needle, producing the electron beam which is transported to a grounded Bremsstrahlung converter within a strong (/spl sim/50 T) axial magnetic field. These systems produce mm-sized stable electron beams, yielding very intense X-ray sources. Detailed simulations of the electron beam generation, transport, and target interaction are presented along with scaling laws for the radiation production and X-ray spot size. Experimental studies confirm these simulations and show this reliable, compact, and inexpensive technology scales to 1000-R doses a meter from a mm-diameter source in 50 ns.","PeriodicalId":11209,"journal":{"name":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","volume":"132 1","pages":"279-282 vol.1"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Inductive voltage adder driven X-ray sources for hydrodynamic radiography\",\"authors\":\"J. Maenchen, S. Cordova, J. Gustwiller, D.L. Johnson, P. Menge, I. Molina, C. Olson, S. Rosenthal, D. Rovang, O. Oliver, D. Welch, V. Bailey, I. Smith, D. Droemer, E. Hunt, G. Macleod, L. Woo\",\"doi\":\"10.1109/PPC.1999.825465\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inductive voltage adder (IVA) accelerators were developed to provide high-current (100s of kA) power pulses at high voltage (up to 20 MV) using robust modular components. This architecture simultaneously resolves problems found in conventional pulsed and linear induction accelerators. A variety of high-brightness pulsed X-ray radiographic sources are needed from submegavolt to 16-MeV endpoints with greater source brightness (dose/spot/sup 2/) than presently available. We are applying IVA systems to produce very intense (up to 75 TW/cm/sup 2/) electron beams for these flash radiographic applications. The accelerator electromagnetic pulse is converted to a directed electron beam at the end of a self-magnetically insulated vacuum transmission line. The cantilevered cathode threading the accelerator cavities terminates in a small (l-mm diameter) needle, producing the electron beam which is transported to a grounded Bremsstrahlung converter within a strong (/spl sim/50 T) axial magnetic field. These systems produce mm-sized stable electron beams, yielding very intense X-ray sources. Detailed simulations of the electron beam generation, transport, and target interaction are presented along with scaling laws for the radiation production and X-ray spot size. Experimental studies confirm these simulations and show this reliable, compact, and inexpensive technology scales to 1000-R doses a meter from a mm-diameter source in 50 ns.\",\"PeriodicalId\":11209,\"journal\":{\"name\":\"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)\",\"volume\":\"132 1\",\"pages\":\"279-282 vol.1\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPC.1999.825465\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1999.825465","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Inductive voltage adder driven X-ray sources for hydrodynamic radiography
Inductive voltage adder (IVA) accelerators were developed to provide high-current (100s of kA) power pulses at high voltage (up to 20 MV) using robust modular components. This architecture simultaneously resolves problems found in conventional pulsed and linear induction accelerators. A variety of high-brightness pulsed X-ray radiographic sources are needed from submegavolt to 16-MeV endpoints with greater source brightness (dose/spot/sup 2/) than presently available. We are applying IVA systems to produce very intense (up to 75 TW/cm/sup 2/) electron beams for these flash radiographic applications. The accelerator electromagnetic pulse is converted to a directed electron beam at the end of a self-magnetically insulated vacuum transmission line. The cantilevered cathode threading the accelerator cavities terminates in a small (l-mm diameter) needle, producing the electron beam which is transported to a grounded Bremsstrahlung converter within a strong (/spl sim/50 T) axial magnetic field. These systems produce mm-sized stable electron beams, yielding very intense X-ray sources. Detailed simulations of the electron beam generation, transport, and target interaction are presented along with scaling laws for the radiation production and X-ray spot size. Experimental studies confirm these simulations and show this reliable, compact, and inexpensive technology scales to 1000-R doses a meter from a mm-diameter source in 50 ns.