{"title":"近5开尔文,无低温,基于脉冲管制冷机的扫描探针显微镜的研制。","authors":"J. Kasai, Tomoki Koyama, M. Yokota, K. Iwaya","doi":"10.1063/5.0084888","DOIUrl":null,"url":null,"abstract":"We report the design and performance of a cryogen-free, pulse-tube refrigerator (PTR)-based scanning probe microscopy (SPM) system capable of operating at a base temperature of near 5 K. We achieve this by combining a home-made interface design between the PTR cold head and the SPM head, with an automatic gas-handling system. The interface design isolates the PTR vibrations by a combination of polytetrafluoroethylene and stainless-steel bellows and by placing the SPM head on a passive vibration isolation table via two cold stages that are connected to thermal radiation shields using copper heat links. The gas-handling system regulates the helium heat-exchange gas pressures, facilitating both the cooldown to and maintenance of the base temperature. We discuss the effects of each component using measured vibration, current-noise, temperature, and pressure data. We demonstrate that our SPM system performance is comparable to known liquid-helium-based systems with the measurements of the superconducting gap spectrum of Pb, atomic-resolution scanning tunneling microscopy image and quasiparticle interference pattern of Au(111) surface, and non-contact atomic force microscopy image of NaCl(100) surface. Without the need for cryogen refills, the present SPM system enables uninterrupted low-temperature measurements.","PeriodicalId":54761,"journal":{"name":"Journal of the Optical Society of America and Review of Scientific Instruments","volume":"21 1","pages":"043711"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Development of a near-5-Kelvin, cryogen-free, pulse-tube refrigerator-based scanning probe microscope.\",\"authors\":\"J. Kasai, Tomoki Koyama, M. Yokota, K. Iwaya\",\"doi\":\"10.1063/5.0084888\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report the design and performance of a cryogen-free, pulse-tube refrigerator (PTR)-based scanning probe microscopy (SPM) system capable of operating at a base temperature of near 5 K. We achieve this by combining a home-made interface design between the PTR cold head and the SPM head, with an automatic gas-handling system. The interface design isolates the PTR vibrations by a combination of polytetrafluoroethylene and stainless-steel bellows and by placing the SPM head on a passive vibration isolation table via two cold stages that are connected to thermal radiation shields using copper heat links. The gas-handling system regulates the helium heat-exchange gas pressures, facilitating both the cooldown to and maintenance of the base temperature. We discuss the effects of each component using measured vibration, current-noise, temperature, and pressure data. We demonstrate that our SPM system performance is comparable to known liquid-helium-based systems with the measurements of the superconducting gap spectrum of Pb, atomic-resolution scanning tunneling microscopy image and quasiparticle interference pattern of Au(111) surface, and non-contact atomic force microscopy image of NaCl(100) surface. Without the need for cryogen refills, the present SPM system enables uninterrupted low-temperature measurements.\",\"PeriodicalId\":54761,\"journal\":{\"name\":\"Journal of the Optical Society of America and Review of Scientific Instruments\",\"volume\":\"21 1\",\"pages\":\"043711\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Optical Society of America and Review of Scientific Instruments\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0084888\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Optical Society of America and Review of Scientific Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0084888","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of a near-5-Kelvin, cryogen-free, pulse-tube refrigerator-based scanning probe microscope.
We report the design and performance of a cryogen-free, pulse-tube refrigerator (PTR)-based scanning probe microscopy (SPM) system capable of operating at a base temperature of near 5 K. We achieve this by combining a home-made interface design between the PTR cold head and the SPM head, with an automatic gas-handling system. The interface design isolates the PTR vibrations by a combination of polytetrafluoroethylene and stainless-steel bellows and by placing the SPM head on a passive vibration isolation table via two cold stages that are connected to thermal radiation shields using copper heat links. The gas-handling system regulates the helium heat-exchange gas pressures, facilitating both the cooldown to and maintenance of the base temperature. We discuss the effects of each component using measured vibration, current-noise, temperature, and pressure data. We demonstrate that our SPM system performance is comparable to known liquid-helium-based systems with the measurements of the superconducting gap spectrum of Pb, atomic-resolution scanning tunneling microscopy image and quasiparticle interference pattern of Au(111) surface, and non-contact atomic force microscopy image of NaCl(100) surface. Without the need for cryogen refills, the present SPM system enables uninterrupted low-temperature measurements.