{"title":"定量血管造影:密度测量引导边缘检测使用平均场退火","authors":"Youn-Sik Han, W. Snyder, D. Herrington","doi":"10.1109/CIC.1993.378493","DOIUrl":null,"url":null,"abstract":"Coronary angiograms are degraded by blur and noise from the imaging system. Previously the authors proposed a method of deblurring and edge-preserving smoothing using Mean Field Annealing. Here, they show the results of the application of DMFA technique on clinical cineangiography. Also, they propose a new edge detection method which uses densitometric information as well as gradient information in the estimation of the edges. These techniques are applied to 13 synthetic vessel images and several clinical angiograms and the results are compared to those of the conventional gradient-based techniques. These methods may improve QCA measures of vessel diameters.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"43 1","pages":"105-108"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Quantitative angiography: densitometry guided edge detection using mean field annealing\",\"authors\":\"Youn-Sik Han, W. Snyder, D. Herrington\",\"doi\":\"10.1109/CIC.1993.378493\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Coronary angiograms are degraded by blur and noise from the imaging system. Previously the authors proposed a method of deblurring and edge-preserving smoothing using Mean Field Annealing. Here, they show the results of the application of DMFA technique on clinical cineangiography. Also, they propose a new edge detection method which uses densitometric information as well as gradient information in the estimation of the edges. These techniques are applied to 13 synthetic vessel images and several clinical angiograms and the results are compared to those of the conventional gradient-based techniques. These methods may improve QCA measures of vessel diameters.<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"43 1\",\"pages\":\"105-108\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378493\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378493","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Quantitative angiography: densitometry guided edge detection using mean field annealing
Coronary angiograms are degraded by blur and noise from the imaging system. Previously the authors proposed a method of deblurring and edge-preserving smoothing using Mean Field Annealing. Here, they show the results of the application of DMFA technique on clinical cineangiography. Also, they propose a new edge detection method which uses densitometric information as well as gradient information in the estimation of the edges. These techniques are applied to 13 synthetic vessel images and several clinical angiograms and the results are compared to those of the conventional gradient-based techniques. These methods may improve QCA measures of vessel diameters.<>