{"title":"滑膜夹持:后路稳定全膝关节置换术的并发症","authors":"D. Pollock, D. Ammeen, G. Engh","doi":"10.2106/00004623-200212000-00008","DOIUrl":null,"url":null,"abstract":"Background: We observed a complication of posterior stabilized total knee arthroplasty involving hypertrophy of tissue proximal to the patella associated with pain during active knee extension from 90° of flexion. The purpose of this paper was to describe synovial entrapment and to determine if design features of the prosthesis predispose patients to the complication.Methods: Between April 1990 and June 1999, we performed 459 consecutive posterior stabilized primary total knee arthroplasties using three prosthetic designs with different femoral intercondylar geometries. We identified twenty-six patients (twenty-seven knees) in whom arthroscopic débridement of the knee or open arthrotomy with débridement of the knee had been subsequently performed because of a diagnosis of synovial entrapment. We reviewed the records of these patients to identify the knee components that had been used and the symptoms and conditions that necessitated additional treatment.Results: Symptoms (grating, crepitation, and pain with active knee extension from 90°) necessitating subsequent débridement occurred in 13.5% (nineteen) of 141 knees treated with the Anatomic Modular Knee-Congruency implant, 3.8% (eight) of 212 treated with the Anatomic Modular Knee-Posterior Stabilized implant, and none of the 106 treated with the Press Fit Condylar Sigma-Posterior Stabilized implant. All patients had difficulty rising from a chair and climbing stairs; however, none had symptoms when standing or walking. No patient had a patellar clunk. The symptoms occurred at a mean of seven months after the arthroplasty in the patients with an Anatomic Modular Knee-Congruency implant and at a mean of twenty months after the arthroplasty in those with an Anatomic Modular Knee-Posterior Stabilized implant. Débridement of the frond-like hypertrophic synovial tissue at the distal aspect of the quadriceps tendon alleviated symptoms in all patients. No nodules were identified during the arthroscopy.Conclusions: Synovial entrapment is characterized by hypertrophic synovial tissue at the superior pole of the patella. Use of a posterior stabilized femoral component with a proximally positioned or wide femoral box is more likely to result in this complication.","PeriodicalId":22625,"journal":{"name":"The Journal of Bone & Joint Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"67","resultStr":"{\"title\":\"Synovial Entrapment: A Complication of Posterior Stabilized Total Knee Arthroplasty\",\"authors\":\"D. Pollock, D. Ammeen, G. Engh\",\"doi\":\"10.2106/00004623-200212000-00008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: We observed a complication of posterior stabilized total knee arthroplasty involving hypertrophy of tissue proximal to the patella associated with pain during active knee extension from 90° of flexion. The purpose of this paper was to describe synovial entrapment and to determine if design features of the prosthesis predispose patients to the complication.Methods: Between April 1990 and June 1999, we performed 459 consecutive posterior stabilized primary total knee arthroplasties using three prosthetic designs with different femoral intercondylar geometries. We identified twenty-six patients (twenty-seven knees) in whom arthroscopic débridement of the knee or open arthrotomy with débridement of the knee had been subsequently performed because of a diagnosis of synovial entrapment. We reviewed the records of these patients to identify the knee components that had been used and the symptoms and conditions that necessitated additional treatment.Results: Symptoms (grating, crepitation, and pain with active knee extension from 90°) necessitating subsequent débridement occurred in 13.5% (nineteen) of 141 knees treated with the Anatomic Modular Knee-Congruency implant, 3.8% (eight) of 212 treated with the Anatomic Modular Knee-Posterior Stabilized implant, and none of the 106 treated with the Press Fit Condylar Sigma-Posterior Stabilized implant. All patients had difficulty rising from a chair and climbing stairs; however, none had symptoms when standing or walking. No patient had a patellar clunk. The symptoms occurred at a mean of seven months after the arthroplasty in the patients with an Anatomic Modular Knee-Congruency implant and at a mean of twenty months after the arthroplasty in those with an Anatomic Modular Knee-Posterior Stabilized implant. Débridement of the frond-like hypertrophic synovial tissue at the distal aspect of the quadriceps tendon alleviated symptoms in all patients. No nodules were identified during the arthroscopy.Conclusions: Synovial entrapment is characterized by hypertrophic synovial tissue at the superior pole of the patella. Use of a posterior stabilized femoral component with a proximally positioned or wide femoral box is more likely to result in this complication.\",\"PeriodicalId\":22625,\"journal\":{\"name\":\"The Journal of Bone & Joint Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"67\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Bone & Joint Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2106/00004623-200212000-00008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Bone & Joint Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2106/00004623-200212000-00008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Synovial Entrapment: A Complication of Posterior Stabilized Total Knee Arthroplasty
Background: We observed a complication of posterior stabilized total knee arthroplasty involving hypertrophy of tissue proximal to the patella associated with pain during active knee extension from 90° of flexion. The purpose of this paper was to describe synovial entrapment and to determine if design features of the prosthesis predispose patients to the complication.Methods: Between April 1990 and June 1999, we performed 459 consecutive posterior stabilized primary total knee arthroplasties using three prosthetic designs with different femoral intercondylar geometries. We identified twenty-six patients (twenty-seven knees) in whom arthroscopic débridement of the knee or open arthrotomy with débridement of the knee had been subsequently performed because of a diagnosis of synovial entrapment. We reviewed the records of these patients to identify the knee components that had been used and the symptoms and conditions that necessitated additional treatment.Results: Symptoms (grating, crepitation, and pain with active knee extension from 90°) necessitating subsequent débridement occurred in 13.5% (nineteen) of 141 knees treated with the Anatomic Modular Knee-Congruency implant, 3.8% (eight) of 212 treated with the Anatomic Modular Knee-Posterior Stabilized implant, and none of the 106 treated with the Press Fit Condylar Sigma-Posterior Stabilized implant. All patients had difficulty rising from a chair and climbing stairs; however, none had symptoms when standing or walking. No patient had a patellar clunk. The symptoms occurred at a mean of seven months after the arthroplasty in the patients with an Anatomic Modular Knee-Congruency implant and at a mean of twenty months after the arthroplasty in those with an Anatomic Modular Knee-Posterior Stabilized implant. Débridement of the frond-like hypertrophic synovial tissue at the distal aspect of the quadriceps tendon alleviated symptoms in all patients. No nodules were identified during the arthroscopy.Conclusions: Synovial entrapment is characterized by hypertrophic synovial tissue at the superior pole of the patella. Use of a posterior stabilized femoral component with a proximally positioned or wide femoral box is more likely to result in this complication.