Chandra Karunakaran, Srishti Saraswat, J. Tak, Hongbo Zhao, H. Xin, R. Witte
{"title":"多层乳房幻影聚焦微波加热过程中的实时热声成像和测温","authors":"Chandra Karunakaran, Srishti Saraswat, J. Tak, Hongbo Zhao, H. Xin, R. Witte","doi":"10.1109/ULTSYM.2019.8925833","DOIUrl":null,"url":null,"abstract":"This study describes real-time thermoacoustic imaging (TAI) and thermometry (TAT) for feedback during thermal therapies. The system uses a linear ultrasound array and imaging system to noninvasively estimate temperature. The system was validated in gel phantoms, muscle and fat tissue samples. A mean error between 10 and 20% per degree was observed for estimating temperature. A TAT system using a single element ultrasound probe was also integrated with a focused microwave therapy (FMT) setup for generating local heating, leading to a mean error of 1.18±0.87 °C compared to thermocouples placed near the region of interest. The results support the long-term goal of developing a closed-loop platform for image-guided ablation therapy for breast cancer.","PeriodicalId":6759,"journal":{"name":"2019 IEEE International Ultrasonics Symposium (IUS)","volume":"70 1","pages":"530-539"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Real-Time Thermoacoustic Imaging and Thermometry during Focused Microwave Heating in Multilayer Breast Phantom\",\"authors\":\"Chandra Karunakaran, Srishti Saraswat, J. Tak, Hongbo Zhao, H. Xin, R. Witte\",\"doi\":\"10.1109/ULTSYM.2019.8925833\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study describes real-time thermoacoustic imaging (TAI) and thermometry (TAT) for feedback during thermal therapies. The system uses a linear ultrasound array and imaging system to noninvasively estimate temperature. The system was validated in gel phantoms, muscle and fat tissue samples. A mean error between 10 and 20% per degree was observed for estimating temperature. A TAT system using a single element ultrasound probe was also integrated with a focused microwave therapy (FMT) setup for generating local heating, leading to a mean error of 1.18±0.87 °C compared to thermocouples placed near the region of interest. The results support the long-term goal of developing a closed-loop platform for image-guided ablation therapy for breast cancer.\",\"PeriodicalId\":6759,\"journal\":{\"name\":\"2019 IEEE International Ultrasonics Symposium (IUS)\",\"volume\":\"70 1\",\"pages\":\"530-539\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE International Ultrasonics Symposium (IUS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2019.8925833\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE International Ultrasonics Symposium (IUS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2019.8925833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Real-Time Thermoacoustic Imaging and Thermometry during Focused Microwave Heating in Multilayer Breast Phantom
This study describes real-time thermoacoustic imaging (TAI) and thermometry (TAT) for feedback during thermal therapies. The system uses a linear ultrasound array and imaging system to noninvasively estimate temperature. The system was validated in gel phantoms, muscle and fat tissue samples. A mean error between 10 and 20% per degree was observed for estimating temperature. A TAT system using a single element ultrasound probe was also integrated with a focused microwave therapy (FMT) setup for generating local heating, leading to a mean error of 1.18±0.87 °C compared to thermocouples placed near the region of interest. The results support the long-term goal of developing a closed-loop platform for image-guided ablation therapy for breast cancer.