{"title":"高效DSP控制有源电力线调节器的新改造","authors":"L. Cheng, R. Cheung, R. Sotudeh","doi":"10.1109/PESC.1996.548752","DOIUrl":null,"url":null,"abstract":"This paper presents a new transformation scheme for the control of an active power-line conditioner, a power electronic device which is designed to suppress the power-line distortions caused by the nonlinear loads. Currently, the method of instantaneous power transformation is the most popular one for the active power-line conditioning control. This method uses the measurements of the power-line voltage and current to estimate the required harmonic compensation. The method requires much hardware for the measurements and many computations. The high accuracy hardware for measurements are costly and many computations can introduce truncation errors. Also, this method is sensitive to the power-line voltage measurements and may introduce control errors. A new simple transformation method is developed to overcome these difficulties. This control computes the correct harmonic compensation using the power-line current measurement only. This requires less hardware for the power-line voltages measurements and simplifies the computational processes. Unlike the traditional method, the accuracy of the new control method is not affected by the line voltage measurements, therefore, it is reliable under any power-line condition. An active power-line conditioner has been successfully developed to validate the accuracy and efficiency of the new control method. Typical test results are given in the paper.","PeriodicalId":19979,"journal":{"name":"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference","volume":"57 1","pages":"1317-1322 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1996-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"New transformation for efficient DSP control of active power-line conditioners\",\"authors\":\"L. Cheng, R. Cheung, R. Sotudeh\",\"doi\":\"10.1109/PESC.1996.548752\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a new transformation scheme for the control of an active power-line conditioner, a power electronic device which is designed to suppress the power-line distortions caused by the nonlinear loads. Currently, the method of instantaneous power transformation is the most popular one for the active power-line conditioning control. This method uses the measurements of the power-line voltage and current to estimate the required harmonic compensation. The method requires much hardware for the measurements and many computations. The high accuracy hardware for measurements are costly and many computations can introduce truncation errors. Also, this method is sensitive to the power-line voltage measurements and may introduce control errors. A new simple transformation method is developed to overcome these difficulties. This control computes the correct harmonic compensation using the power-line current measurement only. This requires less hardware for the power-line voltages measurements and simplifies the computational processes. Unlike the traditional method, the accuracy of the new control method is not affected by the line voltage measurements, therefore, it is reliable under any power-line condition. An active power-line conditioner has been successfully developed to validate the accuracy and efficiency of the new control method. Typical test results are given in the paper.\",\"PeriodicalId\":19979,\"journal\":{\"name\":\"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference\",\"volume\":\"57 1\",\"pages\":\"1317-1322 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1996.548752\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC Record. 27th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1996.548752","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文提出了一种控制有源电力线调节器的新变换方案。有源电力线调节器是一种用于抑制非线性负荷引起的电力线畸变的电力电子设备。目前,功率瞬时变换是电力线有源调节控制中最常用的方法。该方法通过测量电力线电压和电流来估计所需的谐波补偿。该方法需要大量的硬件进行测量和大量的计算。用于测量的高精度硬件价格昂贵,并且多次计算会引入截断误差。此外,这种方法对电力线电压测量很敏感,可能会引入控制误差。为了克服这些困难,提出了一种新的简单变换方法。该控制仅使用电源线电流测量计算正确的谐波补偿。这需要更少的硬件用于电力线电压测量,并简化了计算过程。与传统的控制方法不同,这种控制方法的精度不受线路电压测量的影响,因此在任何电力线条件下都是可靠的。研制成功的有源电力线调节器验证了新控制方法的准确性和有效性。文中给出了典型的试验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
New transformation for efficient DSP control of active power-line conditioners
This paper presents a new transformation scheme for the control of an active power-line conditioner, a power electronic device which is designed to suppress the power-line distortions caused by the nonlinear loads. Currently, the method of instantaneous power transformation is the most popular one for the active power-line conditioning control. This method uses the measurements of the power-line voltage and current to estimate the required harmonic compensation. The method requires much hardware for the measurements and many computations. The high accuracy hardware for measurements are costly and many computations can introduce truncation errors. Also, this method is sensitive to the power-line voltage measurements and may introduce control errors. A new simple transformation method is developed to overcome these difficulties. This control computes the correct harmonic compensation using the power-line current measurement only. This requires less hardware for the power-line voltages measurements and simplifies the computational processes. Unlike the traditional method, the accuracy of the new control method is not affected by the line voltage measurements, therefore, it is reliable under any power-line condition. An active power-line conditioner has been successfully developed to validate the accuracy and efficiency of the new control method. Typical test results are given in the paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信