用Li2MoO4低温探测器精确测量100Mo的2ν2β衰变:初步结果

E. Armengaud, C. Augier, A. Barabash, F. Bellini, A. Benő, M. Beretta, L. Bergé, N. Besson, J. Billard, Yu. A. Borovlev, C. Bourgeois, V. Brudanin, P. Camus, L. Cardani, N. Casali, A. Cazes, M. Chapellier, F. Charlieux, M. D. Combarieu, F. Danevich, I. Dafinei, M. Jésus, L. Dumoulin, K. Eitel, F. Ferri, B. Fujikawa, J. Gascon, L. Gironi, A. Giuliani, V. Grigorieva, M. Gros, E. Guerard, H. Huang, R.Huang Lbnl, J. Johnston, A. Juillard, H. Khalife, M. Kleifges, V. Kobychev, Y. Kolomensky, S. Konovalov, A. Leder, J. Kotila, P. Loaiza, R. Maisonobe, E. Makarov, P. Marcillac, S. Marnieros, X. Navick, C. Nones, V. Novati, E. Olivieri, L. Pagnanini, P. Pari, L. Pattavina, M. Pavan, B. Paul, H. Peng, G. Pessina, S. Pirrò, D. Poda, O. Polischuk, E. Previtali, E. Queguiner, T. Redon, S. Rozov, C. Rusconi, V. Sanglard, K. Schäffner, Y. Shen, B. Schmidt, V. Shlegel, B. Siebenborn, S. Sorbino, C. Tomei, V. Tretyak, V. Umatov, L. Vagneron, M. Velázquez, M. Vignati, M. Weber, L. Winslow, M. Xue, E. Yakushev, A. Zolotaro
{"title":"用Li2MoO4低温探测器精确测量100Mo的2ν2β衰变:初步结果","authors":"E. Armengaud, C. Augier, A. Barabash, F. Bellini, A. Benő, M. Beretta, L. Bergé, N. Besson, J. Billard, Yu. A. Borovlev, C. Bourgeois, V. Brudanin, P. Camus, L. Cardani, N. Casali, A. Cazes, M. Chapellier, F. Charlieux, M. D. Combarieu, F. Danevich, I. Dafinei, M. Jésus, L. Dumoulin, K. Eitel, F. Ferri, B. Fujikawa, J. Gascon, L. Gironi, A. Giuliani, V. Grigorieva, M. Gros, E. Guerard, H. Huang, R.Huang Lbnl, J. Johnston, A. Juillard, H. Khalife, M. Kleifges, V. Kobychev, Y. Kolomensky, S. Konovalov, A. Leder, J. Kotila, P. Loaiza, R. Maisonobe, E. Makarov, P. Marcillac, S. Marnieros, X. Navick, C. Nones, V. Novati, E. Olivieri, L. Pagnanini, P. Pari, L. Pattavina, M. Pavan, B. Paul, H. Peng, G. Pessina, S. Pirrò, D. Poda, O. Polischuk, E. Previtali, E. Queguiner, T. Redon, S. Rozov, C. Rusconi, V. Sanglard, K. Schäffner, Y. Shen, B. Schmidt, V. Shlegel, B. Siebenborn, S. Sorbino, C. Tomei, V. Tretyak, V. Umatov, L. Vagneron, M. Velázquez, M. Vignati, M. Weber, L. Winslow, M. Xue, E. Yakushev, A. Zolotaro","doi":"10.1063/1.5130966","DOIUrl":null,"url":null,"abstract":"The half-life of 100Mo relatively to the 2ν2β decay to the ground state of 100Ru was measured as T1/2 = (6.99±0.15) × 1018 yr with the help of enriched in 100Mo lithium molybdate scintillating bolometers in the EDELWEISS-III low background set-up at the Modane underground laboratory. This is the most accurate value of the 2ν2β half-life of 100Mo.","PeriodicalId":23715,"journal":{"name":"WORKSHOP ON CALCULATION OF DOUBLE-BETA-DECAY MATRIX ELEMENTS (MEDEX’19)","volume":"54 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precise measurement of 2ν2β decay of 100Mo with Li2MoO4 low temperature detectors: Preliminary results\",\"authors\":\"E. Armengaud, C. Augier, A. Barabash, F. Bellini, A. Benő, M. Beretta, L. Bergé, N. Besson, J. Billard, Yu. A. Borovlev, C. Bourgeois, V. Brudanin, P. Camus, L. Cardani, N. Casali, A. Cazes, M. Chapellier, F. Charlieux, M. D. Combarieu, F. Danevich, I. Dafinei, M. Jésus, L. Dumoulin, K. Eitel, F. Ferri, B. Fujikawa, J. Gascon, L. Gironi, A. Giuliani, V. Grigorieva, M. Gros, E. Guerard, H. Huang, R.Huang Lbnl, J. Johnston, A. Juillard, H. Khalife, M. Kleifges, V. Kobychev, Y. Kolomensky, S. Konovalov, A. Leder, J. Kotila, P. Loaiza, R. Maisonobe, E. Makarov, P. Marcillac, S. Marnieros, X. Navick, C. Nones, V. Novati, E. Olivieri, L. Pagnanini, P. Pari, L. Pattavina, M. Pavan, B. Paul, H. Peng, G. Pessina, S. Pirrò, D. Poda, O. Polischuk, E. Previtali, E. Queguiner, T. Redon, S. Rozov, C. Rusconi, V. Sanglard, K. Schäffner, Y. Shen, B. Schmidt, V. Shlegel, B. Siebenborn, S. Sorbino, C. Tomei, V. Tretyak, V. Umatov, L. Vagneron, M. Velázquez, M. Vignati, M. Weber, L. Winslow, M. Xue, E. Yakushev, A. Zolotaro\",\"doi\":\"10.1063/1.5130966\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The half-life of 100Mo relatively to the 2ν2β decay to the ground state of 100Ru was measured as T1/2 = (6.99±0.15) × 1018 yr with the help of enriched in 100Mo lithium molybdate scintillating bolometers in the EDELWEISS-III low background set-up at the Modane underground laboratory. This is the most accurate value of the 2ν2β half-life of 100Mo.\",\"PeriodicalId\":23715,\"journal\":{\"name\":\"WORKSHOP ON CALCULATION OF DOUBLE-BETA-DECAY MATRIX ELEMENTS (MEDEX’19)\",\"volume\":\"54 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"WORKSHOP ON CALCULATION OF DOUBLE-BETA-DECAY MATRIX ELEMENTS (MEDEX’19)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/1.5130966\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"WORKSHOP ON CALCULATION OF DOUBLE-BETA-DECAY MATRIX ELEMENTS (MEDEX’19)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/1.5130966","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在Modane地下实验室的EDELWEISS-III低背景装置中,利用富集的100Mo钼酸锂闪烁辐射热计测量了100Mo相对于2ν2β衰变到100Ru基态的半衰期为T1/2 =(6.99±0.15)× 1018 yr。这是100Mo的2ν2β半衰期最准确的值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Precise measurement of 2ν2β decay of 100Mo with Li2MoO4 low temperature detectors: Preliminary results
The half-life of 100Mo relatively to the 2ν2β decay to the ground state of 100Ru was measured as T1/2 = (6.99±0.15) × 1018 yr with the help of enriched in 100Mo lithium molybdate scintillating bolometers in the EDELWEISS-III low background set-up at the Modane underground laboratory. This is the most accurate value of the 2ν2β half-life of 100Mo.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信