正畸微钉放置角度和结构对骨微钉界面应力分布的影响——三维有限元分析

Genevive L. Machado
{"title":"正畸微钉放置角度和结构对骨微钉界面应力分布的影响——三维有限元分析","authors":"Genevive L. Machado","doi":"10.1016/j.sjdr.2014.01.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Aims</h3><p>The study was conducted to evaluate the effects of orthodontic miniscrew placement angle and structure in terms of length and diameter on stress distribution at the bone miniscrew interface.</p></div><div><h3>Methods</h3><p>10 FE models were created representing miniscrews inserted in the buccal alveolar bone between the maxillary first molar and second premolar to simulate varying angulations of miniscrew placement (90°, 60°, 45°, 30°) to the long axis of the maxillary first molar, varying length (6mm, 8mm, 10mm, 12mm) and varying diameter (1.2mm, 1.3mm, 1.4mm, 1.5mm). In order to simulate retraction forces an identical force of 200 g was applied perpendicular to the long axis of the miniscrew in all the models. Finite Element Modeling Analysis was used to analyze the stress distribution at the bone miniscrew interface.</p></div><div><h3>Results</h3><p>Minimum and maximum stress in the miniscrew was generated at placement angles of 30° and 90° respectively. In the bone minimum and maximum stress was found at placement angles of 90° and 30° respectively. On increasing the miniscrew diameter stress in both the miniscrew and the bone decreased. There was no difference found in the stress distribution patterns with varying miniscrew length.</p></div><div><h3>Conclusion</h3><p>Based on stress patterns, biomechanical stability of the miniscrew is enhanced by a placement angle of 90° to the long axis of the first maxillary molar and a diameter of 1.5 mm for the site selected in this study while miniscrew length has no implication on its stability.</p></div>","PeriodicalId":101249,"journal":{"name":"The Saudi Journal for Dental Research","volume":"5 2","pages":"Pages 73-80"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.sjdr.2014.01.001","citationCount":"15","resultStr":"{\"title\":\"Effects of orthodontic miniscrew placement angle and structure on the stress distribution at the bone miniscrew interface – A 3D finite element analysis\",\"authors\":\"Genevive L. Machado\",\"doi\":\"10.1016/j.sjdr.2014.01.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Aims</h3><p>The study was conducted to evaluate the effects of orthodontic miniscrew placement angle and structure in terms of length and diameter on stress distribution at the bone miniscrew interface.</p></div><div><h3>Methods</h3><p>10 FE models were created representing miniscrews inserted in the buccal alveolar bone between the maxillary first molar and second premolar to simulate varying angulations of miniscrew placement (90°, 60°, 45°, 30°) to the long axis of the maxillary first molar, varying length (6mm, 8mm, 10mm, 12mm) and varying diameter (1.2mm, 1.3mm, 1.4mm, 1.5mm). In order to simulate retraction forces an identical force of 200 g was applied perpendicular to the long axis of the miniscrew in all the models. Finite Element Modeling Analysis was used to analyze the stress distribution at the bone miniscrew interface.</p></div><div><h3>Results</h3><p>Minimum and maximum stress in the miniscrew was generated at placement angles of 30° and 90° respectively. In the bone minimum and maximum stress was found at placement angles of 90° and 30° respectively. On increasing the miniscrew diameter stress in both the miniscrew and the bone decreased. There was no difference found in the stress distribution patterns with varying miniscrew length.</p></div><div><h3>Conclusion</h3><p>Based on stress patterns, biomechanical stability of the miniscrew is enhanced by a placement angle of 90° to the long axis of the first maxillary molar and a diameter of 1.5 mm for the site selected in this study while miniscrew length has no implication on its stability.</p></div>\",\"PeriodicalId\":101249,\"journal\":{\"name\":\"The Saudi Journal for Dental Research\",\"volume\":\"5 2\",\"pages\":\"Pages 73-80\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.sjdr.2014.01.001\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Saudi Journal for Dental Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352003514000033\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Saudi Journal for Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352003514000033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

目的研究正畸微钉放置角度和长度、直径结构对骨微钉界面应力分布的影响。方法在上颌第一磨牙与第二前磨牙之间的颊牙槽骨处建立微型牙套有限元模型,模拟微型牙套与上颌第一磨牙长轴的不同角度(90°、60°、45°、30°)、不同长度(6mm、8mm、10mm、12mm)和不同直径(1.2mm、1.3mm、1.4mm、1.5mm)。为了模拟收缩力,在所有模型中垂直于微螺杆的长轴施加了相同的200g力。采用有限元建模分析方法对骨微孔界面处的应力分布进行了分析。结果微螺杆在放置角度为30°和90°时产生最小和最大应力。在放置角度为90°和30°时,骨应力最小和最大。随着微钉直径的增大,微钉和骨内的应力均减小。不同微晶长度的应力分布模式没有差异。结论基于应力模式,选择与上颌第一磨牙长轴夹角为90°、直径为1.5 mm的位置可以增强微支架的生物力学稳定性,而微支架长度对其稳定性没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of orthodontic miniscrew placement angle and structure on the stress distribution at the bone miniscrew interface – A 3D finite element analysis

Aims

The study was conducted to evaluate the effects of orthodontic miniscrew placement angle and structure in terms of length and diameter on stress distribution at the bone miniscrew interface.

Methods

10 FE models were created representing miniscrews inserted in the buccal alveolar bone between the maxillary first molar and second premolar to simulate varying angulations of miniscrew placement (90°, 60°, 45°, 30°) to the long axis of the maxillary first molar, varying length (6mm, 8mm, 10mm, 12mm) and varying diameter (1.2mm, 1.3mm, 1.4mm, 1.5mm). In order to simulate retraction forces an identical force of 200 g was applied perpendicular to the long axis of the miniscrew in all the models. Finite Element Modeling Analysis was used to analyze the stress distribution at the bone miniscrew interface.

Results

Minimum and maximum stress in the miniscrew was generated at placement angles of 30° and 90° respectively. In the bone minimum and maximum stress was found at placement angles of 90° and 30° respectively. On increasing the miniscrew diameter stress in both the miniscrew and the bone decreased. There was no difference found in the stress distribution patterns with varying miniscrew length.

Conclusion

Based on stress patterns, biomechanical stability of the miniscrew is enhanced by a placement angle of 90° to the long axis of the first maxillary molar and a diameter of 1.5 mm for the site selected in this study while miniscrew length has no implication on its stability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信