{"title":"用于液体分析的无线微系统","authors":"I. Leonte, M. Hunt, G. Sehra, M. Cole, J. Gardner, H. Noh, P. Hesketh","doi":"10.1109/ICSENS.2004.1426321","DOIUrl":null,"url":null,"abstract":"The paper describes both semi-wireless and wireless (433 MHz) liquid sensing systems based upon dual shear horizontal surface acoustic wave (SH-SAW) devices and introduces a novel design concept and a novel principle of detection. Each system comprises an uncoated passive SH-SAW device, a liquid microcell, a device antenna and an associated signal processing unit. The LiTaO/sub 3/-based SH-SAW sensors have dual delay line configurations with different path lengths, the principle of detection being the attenuation and time delay between the signals. The sensors have no biochemical selective layer making them non-specific but create a robust/durable and low-cost system. This sensing system may be applied in the food/beverage industry, medical applications; a functionalized coating can be added for more specific biological applications.","PeriodicalId":20476,"journal":{"name":"Proceedings of IEEE Sensors, 2004.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2004-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Towards a wireless microsystem for liquid analysis\",\"authors\":\"I. Leonte, M. Hunt, G. Sehra, M. Cole, J. Gardner, H. Noh, P. Hesketh\",\"doi\":\"10.1109/ICSENS.2004.1426321\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper describes both semi-wireless and wireless (433 MHz) liquid sensing systems based upon dual shear horizontal surface acoustic wave (SH-SAW) devices and introduces a novel design concept and a novel principle of detection. Each system comprises an uncoated passive SH-SAW device, a liquid microcell, a device antenna and an associated signal processing unit. The LiTaO/sub 3/-based SH-SAW sensors have dual delay line configurations with different path lengths, the principle of detection being the attenuation and time delay between the signals. The sensors have no biochemical selective layer making them non-specific but create a robust/durable and low-cost system. This sensing system may be applied in the food/beverage industry, medical applications; a functionalized coating can be added for more specific biological applications.\",\"PeriodicalId\":20476,\"journal\":{\"name\":\"Proceedings of IEEE Sensors, 2004.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IEEE Sensors, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2004.1426321\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Sensors, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2004.1426321","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文介绍了基于双剪切水平表面声波(SH-SAW)器件的半无线和无线(433 MHz)液体传感系统,并介绍了一种新的设计理念和检测原理。每个系统包括一个无涂层的无源SH-SAW装置、一个液体微电池、一个装置天线和一个相关的信号处理单元。基于LiTaO/sub - 3/的SH-SAW传感器具有不同路径长度的双延迟线配置,检测原理是信号之间的衰减和时间延迟。传感器没有生化选择层,使它们不具有特异性,但却创造了一个坚固耐用和低成本的系统。该传感系统可应用于食品/饮料行业、医疗应用;可添加功能化涂层以用于更特定的生物应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Towards a wireless microsystem for liquid analysis
The paper describes both semi-wireless and wireless (433 MHz) liquid sensing systems based upon dual shear horizontal surface acoustic wave (SH-SAW) devices and introduces a novel design concept and a novel principle of detection. Each system comprises an uncoated passive SH-SAW device, a liquid microcell, a device antenna and an associated signal processing unit. The LiTaO/sub 3/-based SH-SAW sensors have dual delay line configurations with different path lengths, the principle of detection being the attenuation and time delay between the signals. The sensors have no biochemical selective layer making them non-specific but create a robust/durable and low-cost system. This sensing system may be applied in the food/beverage industry, medical applications; a functionalized coating can be added for more specific biological applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信