{"title":"有效的反相高效液相色谱法同时检测和定量制剂中吡哆醇和特立西酮的含量","authors":"Ngabo Yves Musafili, H. Samsodien, M. Aucamp","doi":"10.3390/analytica2040018","DOIUrl":null,"url":null,"abstract":"Tuberculosis (TB) remains a life-threatening infection, and it is well-known that effective TB treatment is associated with multiple drugs administered to infected patients on a daily basis. Terizidone (TZD) is an anti-TB drug used in the treatment of multi-drug resistant and extensively drug-resistant TB but presents with polyneuropathic adverse effects in some patients. To counteract these adverse effects, TZD is typically prescribed with pyridoxine (PDX), well known as Vitamin B6. As part of a pre-formulation study investigating the potential to co-formulate these two compounds, it became necessary to have a simple and reliable reversed-phase high-performance liquid chromatography (RP-HPLC) method. Optimal, simultaneous separation and detection of TZD and PDX were obtained using an isocratic mobile phase setup, consisting of ultrapure water and acetonitrile (30:70% v/v), with 1 mL glacial acetic acid added to the mobile phase mixture. A Discovery® C18, 150 × 4.6 mm, 5 μm column maintained at ambient temperature was utilized, with a detection wavelength of 260 nm. The method was validated in terms of linearity, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), specificity, robustness, and solution stability. Validation proved this method to be acceptable and reliable for the simultaneous accurate detection and quantification of TZD and PDX.","PeriodicalId":7829,"journal":{"name":"Analytica","volume":"35 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Validated RP-HPLC Method for the Simultaneous Detection and Quantification of Pyridoxine and Terizidone in Pharmaceutical Formulations\",\"authors\":\"Ngabo Yves Musafili, H. Samsodien, M. Aucamp\",\"doi\":\"10.3390/analytica2040018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Tuberculosis (TB) remains a life-threatening infection, and it is well-known that effective TB treatment is associated with multiple drugs administered to infected patients on a daily basis. Terizidone (TZD) is an anti-TB drug used in the treatment of multi-drug resistant and extensively drug-resistant TB but presents with polyneuropathic adverse effects in some patients. To counteract these adverse effects, TZD is typically prescribed with pyridoxine (PDX), well known as Vitamin B6. As part of a pre-formulation study investigating the potential to co-formulate these two compounds, it became necessary to have a simple and reliable reversed-phase high-performance liquid chromatography (RP-HPLC) method. Optimal, simultaneous separation and detection of TZD and PDX were obtained using an isocratic mobile phase setup, consisting of ultrapure water and acetonitrile (30:70% v/v), with 1 mL glacial acetic acid added to the mobile phase mixture. A Discovery® C18, 150 × 4.6 mm, 5 μm column maintained at ambient temperature was utilized, with a detection wavelength of 260 nm. The method was validated in terms of linearity, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), specificity, robustness, and solution stability. Validation proved this method to be acceptable and reliable for the simultaneous accurate detection and quantification of TZD and PDX.\",\"PeriodicalId\":7829,\"journal\":{\"name\":\"Analytica\",\"volume\":\"35 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/analytica2040018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/analytica2040018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
结核病仍然是一种危及生命的感染,众所周知,有效的结核病治疗与每天向感染患者施用多种药物有关。特立齐酮(TZD)是一种用于治疗多重耐药和广泛耐药结核病的抗结核药物,但在一些患者中出现多神经病变不良反应。为了抵消这些副作用,TZD通常与吡哆醇(PDX)一起开处方,也就是众所周知的维生素B6。作为研究这两种化合物共配制可能性的制剂前研究的一部分,有必要建立一种简单可靠的反相高效液相色谱(RP-HPLC)方法。以超纯水和乙腈(30:70 v/v)为流动相,在流动相混合物中加入1 mL冰醋酸,采用等温流动相设置,获得了同时分离和检测TZD和PDX的最佳方法。采用Discovery®C18色谱柱,150 × 4.6 mm, 5 μm,常温保存,检测波长260 nm。从线性、准确度、精密度、检出限(LOD)、定量限(LOQ)、特异性、鲁棒性和溶液稳定性等方面对方法进行了验证。验证结果表明,该方法可用于同时准确检测和定量TZD和PDX。
A Validated RP-HPLC Method for the Simultaneous Detection and Quantification of Pyridoxine and Terizidone in Pharmaceutical Formulations
Tuberculosis (TB) remains a life-threatening infection, and it is well-known that effective TB treatment is associated with multiple drugs administered to infected patients on a daily basis. Terizidone (TZD) is an anti-TB drug used in the treatment of multi-drug resistant and extensively drug-resistant TB but presents with polyneuropathic adverse effects in some patients. To counteract these adverse effects, TZD is typically prescribed with pyridoxine (PDX), well known as Vitamin B6. As part of a pre-formulation study investigating the potential to co-formulate these two compounds, it became necessary to have a simple and reliable reversed-phase high-performance liquid chromatography (RP-HPLC) method. Optimal, simultaneous separation and detection of TZD and PDX were obtained using an isocratic mobile phase setup, consisting of ultrapure water and acetonitrile (30:70% v/v), with 1 mL glacial acetic acid added to the mobile phase mixture. A Discovery® C18, 150 × 4.6 mm, 5 μm column maintained at ambient temperature was utilized, with a detection wavelength of 260 nm. The method was validated in terms of linearity, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), specificity, robustness, and solution stability. Validation proved this method to be acceptable and reliable for the simultaneous accurate detection and quantification of TZD and PDX.