医用表面改性钢的力学性能和抗菌性能研究

Q3 Engineering
A. Taratuta, J. Lisoń, Alicja Kazik-Kęsik, M. Antonowicz, M. Basiaga
{"title":"医用表面改性钢的力学性能和抗菌性能研究","authors":"A. Taratuta, J. Lisoń, Alicja Kazik-Kęsik, M. Antonowicz, M. Basiaga","doi":"10.5604/01.3001.0053.6128","DOIUrl":null,"url":null,"abstract":"Various types of metal implants, both in Poland and worldwide, are mainly manufactured from stainlesssteel due to their biocompatibility, strength, and relatively low price. However, any such procedure involvesthe risk of peri-implant infection, stimulated, among other things, by the formation of a bacterial biofilmon the surface of the implant. In this paper, several methods of modifying the surface of steel for medicalapplications were proposed, such as mechanical polishing, electropolishing, sandblasting, and the applicationof a thin surface layer. This was followed by a series of physicochemical and biological tests. The resultsindicate that the titanium nitride coating improved corrosion resistance and reduced bacterial adhesion onthe surface. No significant improvement in abrasion was observed, and the adhesion of the coating closelydepended on the method of preparation.","PeriodicalId":35004,"journal":{"name":"Tribologia: Finnish Journal of Tribology","volume":"12 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"STUDY OF THE MECHANICAL AND ANTIBACTERIALPROPERTIES OF SURFACE MODIFIED STEEL FOR MEDICALAPPLICATIONS\",\"authors\":\"A. Taratuta, J. Lisoń, Alicja Kazik-Kęsik, M. Antonowicz, M. Basiaga\",\"doi\":\"10.5604/01.3001.0053.6128\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Various types of metal implants, both in Poland and worldwide, are mainly manufactured from stainlesssteel due to their biocompatibility, strength, and relatively low price. However, any such procedure involvesthe risk of peri-implant infection, stimulated, among other things, by the formation of a bacterial biofilmon the surface of the implant. In this paper, several methods of modifying the surface of steel for medicalapplications were proposed, such as mechanical polishing, electropolishing, sandblasting, and the applicationof a thin surface layer. This was followed by a series of physicochemical and biological tests. The resultsindicate that the titanium nitride coating improved corrosion resistance and reduced bacterial adhesion onthe surface. No significant improvement in abrasion was observed, and the adhesion of the coating closelydepended on the method of preparation.\",\"PeriodicalId\":35004,\"journal\":{\"name\":\"Tribologia: Finnish Journal of Tribology\",\"volume\":\"12 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tribologia: Finnish Journal of Tribology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5604/01.3001.0053.6128\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tribologia: Finnish Journal of Tribology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0053.6128","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

由于其生物相容性、强度和相对低廉的价格,在波兰和世界范围内,各种类型的金属植入物主要由不锈钢制造。然而,任何这样的手术都有种植体周围感染的风险,除了其他因素外,还会由于种植体表面形成细菌生物膜而受到刺激。本文提出了几种用于医学用途的钢表面改性方法,如机械抛光、电抛光、喷砂和薄表面层的应用。随后进行了一系列的物理化学和生物测试。结果表明,氮化钛涂层提高了材料的耐蚀性,减少了表面细菌附着。涂层的耐磨性无明显改善,涂层的附着力与制备方法密切相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
STUDY OF THE MECHANICAL AND ANTIBACTERIALPROPERTIES OF SURFACE MODIFIED STEEL FOR MEDICALAPPLICATIONS
Various types of metal implants, both in Poland and worldwide, are mainly manufactured from stainlesssteel due to their biocompatibility, strength, and relatively low price. However, any such procedure involvesthe risk of peri-implant infection, stimulated, among other things, by the formation of a bacterial biofilmon the surface of the implant. In this paper, several methods of modifying the surface of steel for medicalapplications were proposed, such as mechanical polishing, electropolishing, sandblasting, and the applicationof a thin surface layer. This was followed by a series of physicochemical and biological tests. The resultsindicate that the titanium nitride coating improved corrosion resistance and reduced bacterial adhesion onthe surface. No significant improvement in abrasion was observed, and the adhesion of the coating closelydepended on the method of preparation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Tribologia: Finnish Journal of Tribology
Tribologia: Finnish Journal of Tribology Materials Science-Surfaces, Coatings and Films
CiteScore
2.20
自引率
0.00%
发文量
4
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信