{"title":"金属仪器包装中包含的棉织物在蒸汽灭菌后保持包装内的湿度","authors":"Kanisa Chantarothorn, Nattakarn Narongchai, Apisara Trairattanapa, Chompoonuch Wongwiriya, R. Ampornaramveth","doi":"10.5005/jp-journals-10031-1255","DOIUrl":null,"url":null,"abstract":"Ab s t r Ac t Aim: Packages that are wet after steam sterilization are identified as a failure in the sterilization process. The objective was to investigate whether different fabric loads and packaging materials affect temperature and humidity inside the packages after steam sterilization. Materials and methods: Four groups of instrument packages containing either metal instruments alone or various types of fabric load (cotton, towel, or a combination) were prepared with three different packaging materials (cotton fabric, nonwoven material, or paper-film). The packages were then subjected to a full cycle steam sterilization at 121°C for 20 minutes. Percent humidity and temperature were determined immediately after removal of the package from the sterilizing chamber, and after every 15 minutes to 1 hour. Results: The presence of any fabric inside the packages significantly increased intrapackage humidity immediately after removal from the sterilizing chamber. Intrapackage humidity dropped sharply in the packages containing metal alone or towel. The presence of cotton fabric inside the packages retained higher intrapackage humidity at every time point. The packages with metal alone had a significantly lower temperature compared with the other three groups when measured immediately. Intrapackage temperature gradually decreased in time. There was no difference in temperature between the groups from 15 minutes. The packages wrapped in cotton fabric significantly retained immediate intrapackage humidity compared with nonwoven materials or paper-film pouch. Conclusion: Packages containing cotton fabric retained intrapackage humidity; and this may cause sterilization failure. Clinical significance: Our data provided evidence to support that cotton fabric should not be included in the package of metal instruments for steam sterilization in routine dental instrument processing protocols.","PeriodicalId":13857,"journal":{"name":"International Journal of Contemporary Dentistry","volume":"110 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inclusion of Cotton Fabric in a Package of Metal Instruments Retained Intrapackage Humidity after Steam Sterilization\",\"authors\":\"Kanisa Chantarothorn, Nattakarn Narongchai, Apisara Trairattanapa, Chompoonuch Wongwiriya, R. Ampornaramveth\",\"doi\":\"10.5005/jp-journals-10031-1255\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ab s t r Ac t Aim: Packages that are wet after steam sterilization are identified as a failure in the sterilization process. The objective was to investigate whether different fabric loads and packaging materials affect temperature and humidity inside the packages after steam sterilization. Materials and methods: Four groups of instrument packages containing either metal instruments alone or various types of fabric load (cotton, towel, or a combination) were prepared with three different packaging materials (cotton fabric, nonwoven material, or paper-film). The packages were then subjected to a full cycle steam sterilization at 121°C for 20 minutes. Percent humidity and temperature were determined immediately after removal of the package from the sterilizing chamber, and after every 15 minutes to 1 hour. Results: The presence of any fabric inside the packages significantly increased intrapackage humidity immediately after removal from the sterilizing chamber. Intrapackage humidity dropped sharply in the packages containing metal alone or towel. The presence of cotton fabric inside the packages retained higher intrapackage humidity at every time point. The packages with metal alone had a significantly lower temperature compared with the other three groups when measured immediately. Intrapackage temperature gradually decreased in time. There was no difference in temperature between the groups from 15 minutes. The packages wrapped in cotton fabric significantly retained immediate intrapackage humidity compared with nonwoven materials or paper-film pouch. Conclusion: Packages containing cotton fabric retained intrapackage humidity; and this may cause sterilization failure. Clinical significance: Our data provided evidence to support that cotton fabric should not be included in the package of metal instruments for steam sterilization in routine dental instrument processing protocols.\",\"PeriodicalId\":13857,\"journal\":{\"name\":\"International Journal of Contemporary Dentistry\",\"volume\":\"110 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Contemporary Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5005/jp-journals-10031-1255\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Contemporary Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10031-1255","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:蒸汽灭菌后湿的包装被认定为灭菌过程中的失败。目的是研究不同的织物负荷和包装材料是否影响蒸汽灭菌后包装内的温度和湿度。材料和方法:用三种不同的包装材料(棉织物、非织造材料或纸膜)制备四组仪器包装,其中包括单独的金属仪器或各种类型的织物负载(棉、毛巾或组合)。然后在121°C下进行20分钟的全循环蒸汽灭菌。从灭菌室取出包装后立即测定百分比湿度和温度,每隔15分钟至1小时测定一次。结果:从灭菌室取出后,包装内任何织物的存在都会显著增加包装内的湿度。单独装有金属或毛巾的包装内湿度急剧下降。包装内的棉织物在每个时间点保持较高的包装内湿度。当立即测量时,单独使用金属的包装的温度明显低于其他三组。随着时间的推移,包装内温度逐渐降低。从15分钟开始,两组之间的温度没有差异。与非织造材料或纸膜袋相比,包裹在棉织物中的包装显著地保留了包装内的即时湿度。结论:含有棉织物的包装保留了包装内的湿度;这可能会导致消毒失败。临床意义:我们的数据支持在常规牙科器械加工方案中不应将棉织物包装在用于蒸汽灭菌的金属器械中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inclusion of Cotton Fabric in a Package of Metal Instruments Retained Intrapackage Humidity after Steam Sterilization
Ab s t r Ac t Aim: Packages that are wet after steam sterilization are identified as a failure in the sterilization process. The objective was to investigate whether different fabric loads and packaging materials affect temperature and humidity inside the packages after steam sterilization. Materials and methods: Four groups of instrument packages containing either metal instruments alone or various types of fabric load (cotton, towel, or a combination) were prepared with three different packaging materials (cotton fabric, nonwoven material, or paper-film). The packages were then subjected to a full cycle steam sterilization at 121°C for 20 minutes. Percent humidity and temperature were determined immediately after removal of the package from the sterilizing chamber, and after every 15 minutes to 1 hour. Results: The presence of any fabric inside the packages significantly increased intrapackage humidity immediately after removal from the sterilizing chamber. Intrapackage humidity dropped sharply in the packages containing metal alone or towel. The presence of cotton fabric inside the packages retained higher intrapackage humidity at every time point. The packages with metal alone had a significantly lower temperature compared with the other three groups when measured immediately. Intrapackage temperature gradually decreased in time. There was no difference in temperature between the groups from 15 minutes. The packages wrapped in cotton fabric significantly retained immediate intrapackage humidity compared with nonwoven materials or paper-film pouch. Conclusion: Packages containing cotton fabric retained intrapackage humidity; and this may cause sterilization failure. Clinical significance: Our data provided evidence to support that cotton fabric should not be included in the package of metal instruments for steam sterilization in routine dental instrument processing protocols.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信