一种16通道1.1mm2可植入癫痫控制SoC,功耗为亚μ w /通道,采用0.18µm CMOS进行闭环刺激

Mahsa Shoaran, Masoud Shahshahani, Masoud Farivar, J. Almajano, Amirhossein Shahshahani, A. Schmid, A. Bragin, Y. Leblebici, A. Emami-Neyestanak
{"title":"一种16通道1.1mm2可植入癫痫控制SoC,功耗为亚μ w /通道,采用0.18µm CMOS进行闭环刺激","authors":"Mahsa Shoaran, Masoud Shahshahani, Masoud Farivar, J. Almajano, Amirhossein Shahshahani, A. Schmid, A. Bragin, Y. Leblebici, A. Emami-Neyestanak","doi":"10.1109/VLSIC.2016.7573557","DOIUrl":null,"url":null,"abstract":"We present a 16-channel seizure detection system-on-chip (SoC) with 0.92μW/channel power dissipation in a total area of 1.1mm2 including a closed-loop neural stimulator. A set of four features are extracted from the spatially filtered neural data to achieve a high detection accuracy at minimal hardware cost. The performance is demonstrated by early detection and termination of kainic acid-induced seizures in freely moving rats and by offline evaluation on human intracranial EEG (iEEG) data. Our design improves upon previous works by over 40× reduction in power-area product per channel. This improvement is a key step towards integration of larger arrays with higher spatiotemporal resolution to further boost the detection accuracy.","PeriodicalId":6512,"journal":{"name":"2016 IEEE Symposium on VLSI Circuits (VLSI-Circuits)","volume":"12 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"27","resultStr":"{\"title\":\"A 16-channel 1.1mm2 implantable seizure control SoC with sub-μW/channel consumption and closed-loop stimulation in 0.18µm CMOS\",\"authors\":\"Mahsa Shoaran, Masoud Shahshahani, Masoud Farivar, J. Almajano, Amirhossein Shahshahani, A. Schmid, A. Bragin, Y. Leblebici, A. Emami-Neyestanak\",\"doi\":\"10.1109/VLSIC.2016.7573557\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a 16-channel seizure detection system-on-chip (SoC) with 0.92μW/channel power dissipation in a total area of 1.1mm2 including a closed-loop neural stimulator. A set of four features are extracted from the spatially filtered neural data to achieve a high detection accuracy at minimal hardware cost. The performance is demonstrated by early detection and termination of kainic acid-induced seizures in freely moving rats and by offline evaluation on human intracranial EEG (iEEG) data. Our design improves upon previous works by over 40× reduction in power-area product per channel. This improvement is a key step towards integration of larger arrays with higher spatiotemporal resolution to further boost the detection accuracy.\",\"PeriodicalId\":6512,\"journal\":{\"name\":\"2016 IEEE Symposium on VLSI Circuits (VLSI-Circuits)\",\"volume\":\"12 1\",\"pages\":\"1-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"27\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Symposium on VLSI Circuits (VLSI-Circuits)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/VLSIC.2016.7573557\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Symposium on VLSI Circuits (VLSI-Circuits)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VLSIC.2016.7573557","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 27

摘要

我们提出了一个16通道的片上系统(SoC),功耗为0.92μW/通道,总面积为1.1mm2,包括一个闭环神经刺激器。从空间滤波后的神经数据中提取出一组四个特征,以最小的硬件成本达到较高的检测精度。通过早期发现和终止自由运动大鼠的卡因酸诱发癫痫发作,以及对人颅内脑电图(iEEG)数据的离线评估,证明了其性能。我们的设计改进了以前的工作,每个通道的功率面积产品减少了40倍以上。这一改进是将更大的阵列与更高的时空分辨率相结合以进一步提高探测精度的关键一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A 16-channel 1.1mm2 implantable seizure control SoC with sub-μW/channel consumption and closed-loop stimulation in 0.18µm CMOS
We present a 16-channel seizure detection system-on-chip (SoC) with 0.92μW/channel power dissipation in a total area of 1.1mm2 including a closed-loop neural stimulator. A set of four features are extracted from the spatially filtered neural data to achieve a high detection accuracy at minimal hardware cost. The performance is demonstrated by early detection and termination of kainic acid-induced seizures in freely moving rats and by offline evaluation on human intracranial EEG (iEEG) data. Our design improves upon previous works by over 40× reduction in power-area product per channel. This improvement is a key step towards integration of larger arrays with higher spatiotemporal resolution to further boost the detection accuracy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信