A. Peter Snyder, Waleed M. Maswadeh, Ashish Tripathi, Jacek P. Dworzanski
{"title":"热裂解-气相色谱-离子迁移谱法检测室外革兰氏阴性厄尔温菌气溶胶","authors":"A. Peter Snyder, Waleed M. Maswadeh, Ashish Tripathi, Jacek P. Dworzanski","doi":"10.1002/1520-6521(2000)4:2/3<111::AID-FACT5>3.0.CO;2-A","DOIUrl":null,"url":null,"abstract":"<p>Aerosol particulate species of the gram-negative bacterium <i>Erwinia herbicola</i> (EH) were detected by stand-alone, analytical instrumentation in an outdoor western United States desert test site. The device consisted of an aerosol collector interfaced to a quartz-tube pyrolysis–gas chromatography/ion-mobility spectrometer (Py-GC/IMS). The detector is about the size of a shoebox, that is, 12 × 9 × 6 in. Bacterial aerosols and background particulates in the 2 to 10 μm-diameter range were collected by a 1000-l/min aerosol concentrator and deposited onto a filter in a quartz tube. Rapid heating to 350 °C in 5 s effected vaporization, and a portion of the pyrolyzate was directed into a GC column. The eluate was detected by the atmospheric-pressure–based IMS. A distinct peak in the GC/IMS data window was used to signal the presence of the EH bacterial aerosol. The sensitivity of this method was relatively good in that values down to five EH-containing aerosol particles per liter of air could be detected in approximately 2.5 min. © 2000 John Wiley & Sons, Inc. Field Analyt Chem Technol 4: 111–126, 2000</p>","PeriodicalId":100527,"journal":{"name":"Field Analytical Chemistry & Technology","volume":"4 2-3","pages":"111-126"},"PeriodicalIF":0.0000,"publicationDate":"2000-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1520-6521(2000)4:2/3<111::AID-FACT5>3.0.CO;2-A","citationCount":"22","resultStr":"{\"title\":\"Detection of gram-negative Erwinia herbicola outdoor aerosols with pyrolysis–gas chromatography/ion-mobility spectrometry\",\"authors\":\"A. Peter Snyder, Waleed M. Maswadeh, Ashish Tripathi, Jacek P. Dworzanski\",\"doi\":\"10.1002/1520-6521(2000)4:2/3<111::AID-FACT5>3.0.CO;2-A\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Aerosol particulate species of the gram-negative bacterium <i>Erwinia herbicola</i> (EH) were detected by stand-alone, analytical instrumentation in an outdoor western United States desert test site. The device consisted of an aerosol collector interfaced to a quartz-tube pyrolysis–gas chromatography/ion-mobility spectrometer (Py-GC/IMS). The detector is about the size of a shoebox, that is, 12 × 9 × 6 in. Bacterial aerosols and background particulates in the 2 to 10 μm-diameter range were collected by a 1000-l/min aerosol concentrator and deposited onto a filter in a quartz tube. Rapid heating to 350 °C in 5 s effected vaporization, and a portion of the pyrolyzate was directed into a GC column. The eluate was detected by the atmospheric-pressure–based IMS. A distinct peak in the GC/IMS data window was used to signal the presence of the EH bacterial aerosol. The sensitivity of this method was relatively good in that values down to five EH-containing aerosol particles per liter of air could be detected in approximately 2.5 min. © 2000 John Wiley & Sons, Inc. Field Analyt Chem Technol 4: 111–126, 2000</p>\",\"PeriodicalId\":100527,\"journal\":{\"name\":\"Field Analytical Chemistry & Technology\",\"volume\":\"4 2-3\",\"pages\":\"111-126\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/1520-6521(2000)4:2/3<111::AID-FACT5>3.0.CO;2-A\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Field Analytical Chemistry & Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/1520-6521%282000%294%3A2/3%3C111%3A%3AAID-FACT5%3E3.0.CO%3B2-A\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry & Technology","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/1520-6521%282000%294%3A2/3%3C111%3A%3AAID-FACT5%3E3.0.CO%3B2-A","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22