{"title":"鼠笼式异步电动机转子破碎的分析与故障诊断","authors":"T. Ishikawa, R. Ishigame, M. Matsunami, N. Kurita","doi":"10.1541/IEEJJIA.2.292","DOIUrl":null,"url":null,"abstract":"This paper investigates the diagnosis of not only broken-bar but also broken-end ring faults. The difference between the broken bar and broken end ring is clarified experimentally by the Fourier analysis and the wavelet analysis of stator current. Moreover, the electromagnetic field in the healthy rotor and the rotor with broken bar is analyzed to clarify the effect of the failures.","PeriodicalId":6398,"journal":{"name":"2012 15th International Conference on Electrical Machines and Systems (ICEMS)","volume":"36 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Analysis and failure diagnosis of squirrel-cage induction motor with broken rotor\",\"authors\":\"T. Ishikawa, R. Ishigame, M. Matsunami, N. Kurita\",\"doi\":\"10.1541/IEEJJIA.2.292\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates the diagnosis of not only broken-bar but also broken-end ring faults. The difference between the broken bar and broken end ring is clarified experimentally by the Fourier analysis and the wavelet analysis of stator current. Moreover, the electromagnetic field in the healthy rotor and the rotor with broken bar is analyzed to clarify the effect of the failures.\",\"PeriodicalId\":6398,\"journal\":{\"name\":\"2012 15th International Conference on Electrical Machines and Systems (ICEMS)\",\"volume\":\"36 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 15th International Conference on Electrical Machines and Systems (ICEMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1541/IEEJJIA.2.292\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 15th International Conference on Electrical Machines and Systems (ICEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1541/IEEJJIA.2.292","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis and failure diagnosis of squirrel-cage induction motor with broken rotor
This paper investigates the diagnosis of not only broken-bar but also broken-end ring faults. The difference between the broken bar and broken end ring is clarified experimentally by the Fourier analysis and the wavelet analysis of stator current. Moreover, the electromagnetic field in the healthy rotor and the rotor with broken bar is analyzed to clarify the effect of the failures.