{"title":"心电图与单天线系统的心跳活动检测","authors":"D. Obeid, G. Zaharia, S. Sadek, G. E. Zein","doi":"10.1145/2093698.2093838","DOIUrl":null,"url":null,"abstract":"This paper presents a single antenna Doppler system for contact-less heartbeat monitoring. The proposed system, based on using a vector network analyzer, is tested at 16 GHz frequency for different transmitted power levels between 0 and -25 dBm. Both heartbeat rate and heart rate variability are extracted from the signals obtained with the Doppler system and compared to simultaneous ECG signals.","PeriodicalId":91990,"journal":{"name":"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies","volume":"49 1","pages":"140:1-140:5"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"ECG vs. single-antenna system for heartbeat activity detection\",\"authors\":\"D. Obeid, G. Zaharia, S. Sadek, G. E. Zein\",\"doi\":\"10.1145/2093698.2093838\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a single antenna Doppler system for contact-less heartbeat monitoring. The proposed system, based on using a vector network analyzer, is tested at 16 GHz frequency for different transmitted power levels between 0 and -25 dBm. Both heartbeat rate and heart rate variability are extracted from the signals obtained with the Doppler system and compared to simultaneous ECG signals.\",\"PeriodicalId\":91990,\"journal\":{\"name\":\"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies\",\"volume\":\"49 1\",\"pages\":\"140:1-140:5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/2093698.2093838\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2093698.2093838","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
ECG vs. single-antenna system for heartbeat activity detection
This paper presents a single antenna Doppler system for contact-less heartbeat monitoring. The proposed system, based on using a vector network analyzer, is tested at 16 GHz frequency for different transmitted power levels between 0 and -25 dBm. Both heartbeat rate and heart rate variability are extracted from the signals obtained with the Doppler system and compared to simultaneous ECG signals.