同步降压变换器中一种更精确的功率MOSFET电流镜像传感方案

Wenkang Huang, D. Clavette, Mudassar Khatib
{"title":"同步降压变换器中一种更精确的功率MOSFET电流镜像传感方案","authors":"Wenkang Huang, D. Clavette, Mudassar Khatib","doi":"10.1109/APEC42165.2021.9487040","DOIUrl":null,"url":null,"abstract":"This paper presents a current-mirror sensing scheme for high-current trench MOSFETs in synchronous buck converters and implements in a three-die PQFN package capable of delivering 70-A current per phase. Current signal accuracy is critical in high-current multiphase converters that power CPUs, GPUs, DDR memories, and FPGAs in high-performance computers and artificial intelligence systems, since the current information is used not only in optimization of computer system performance and adaptive voltage positioning but also for current sharing between multiple phases and converter over-current protection. Inductor DCR and MOSFET RDS(on) current sensing methods have been used in synchronous buck converters for more than a decade, but the current sensing accuracy is limited to +/-10% and +/-5% respectively and becomes even worse when application conditions vary in wider ranges. Higher current reporting accuracy of the MOSFET current mirror sensing is experimentally verified using multiple synchronous buck converter boards, which are built to measure current sensing error of each power stage and to determine distribution of system current reporting tolerance. Smaller than +/-3%, 3-sigma current error is achieved over wide application ranges of ambient temperature and MOSFET gate drive voltage.","PeriodicalId":7050,"journal":{"name":"2021 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A More Accurate Power MOSFET Current Mirror Sensing Scheme in Synchronous Buck Converters\",\"authors\":\"Wenkang Huang, D. Clavette, Mudassar Khatib\",\"doi\":\"10.1109/APEC42165.2021.9487040\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a current-mirror sensing scheme for high-current trench MOSFETs in synchronous buck converters and implements in a three-die PQFN package capable of delivering 70-A current per phase. Current signal accuracy is critical in high-current multiphase converters that power CPUs, GPUs, DDR memories, and FPGAs in high-performance computers and artificial intelligence systems, since the current information is used not only in optimization of computer system performance and adaptive voltage positioning but also for current sharing between multiple phases and converter over-current protection. Inductor DCR and MOSFET RDS(on) current sensing methods have been used in synchronous buck converters for more than a decade, but the current sensing accuracy is limited to +/-10% and +/-5% respectively and becomes even worse when application conditions vary in wider ranges. Higher current reporting accuracy of the MOSFET current mirror sensing is experimentally verified using multiple synchronous buck converter boards, which are built to measure current sensing error of each power stage and to determine distribution of system current reporting tolerance. Smaller than +/-3%, 3-sigma current error is achieved over wide application ranges of ambient temperature and MOSFET gate drive voltage.\",\"PeriodicalId\":7050,\"journal\":{\"name\":\"2021 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC42165.2021.9487040\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC42165.2021.9487040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文提出了一种用于同步降压变换器中大电流沟槽mosfet的电流反射传感方案,并实现了一个每相能提供70 a电流的三晶PQFN封装。电流信号的准确性对于高性能计算机和人工智能系统中为cpu、gpu、DDR存储器和fpga供电的大电流多相转换器至关重要,因为电流信息不仅用于优化计算机系统性能和自适应电压定位,还用于多相电流共享和转换器过流保护。电感式DCR和MOSFET的RDS(on)电流传感方法已经在同步降压变换器中使用了十多年,但是电流传感精度分别限制在+/-10%和+/-5%,并且当应用条件在更大范围内变化时变得更差。利用多个同步降压变换器板,通过实验验证了MOSFET电流镜像传感具有较高的电流报告精度,这些板用于测量每个功率级的电流传感误差,并确定系统电流报告容限的分布。在环境温度和MOSFET栅极驱动电压的广泛应用范围内,电流误差小于+/-3%,达到3 σ。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A More Accurate Power MOSFET Current Mirror Sensing Scheme in Synchronous Buck Converters
This paper presents a current-mirror sensing scheme for high-current trench MOSFETs in synchronous buck converters and implements in a three-die PQFN package capable of delivering 70-A current per phase. Current signal accuracy is critical in high-current multiphase converters that power CPUs, GPUs, DDR memories, and FPGAs in high-performance computers and artificial intelligence systems, since the current information is used not only in optimization of computer system performance and adaptive voltage positioning but also for current sharing between multiple phases and converter over-current protection. Inductor DCR and MOSFET RDS(on) current sensing methods have been used in synchronous buck converters for more than a decade, but the current sensing accuracy is limited to +/-10% and +/-5% respectively and becomes even worse when application conditions vary in wider ranges. Higher current reporting accuracy of the MOSFET current mirror sensing is experimentally verified using multiple synchronous buck converter boards, which are built to measure current sensing error of each power stage and to determine distribution of system current reporting tolerance. Smaller than +/-3%, 3-sigma current error is achieved over wide application ranges of ambient temperature and MOSFET gate drive voltage.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信