低落差COT降压变换器没有最大占空比限制,由于最小的关闭时间

M. Gobbi, Adalberto Mariani
{"title":"低落差COT降压变换器没有最大占空比限制,由于最小的关闭时间","authors":"M. Gobbi, Adalberto Mariani","doi":"10.23919/AEIT50178.2020.9241198","DOIUrl":null,"url":null,"abstract":"Constant On-Time (COT) buck DC-DC converters are widely used due to high responsiveness, reliability and simple design. However, maximum duty cycle and inductor charging slew rate are limited by minimum Off-Time [1]. The proposed solution overcomes these limitations, providing a wide output range converter with enhanced transient response. A constant on time buck converter, where On-Time is extended beyond the internal timer if output voltage is lower than reference, is proposed. As a benefit, there is no limitation to maximum duty cycle due to minimum off time, just allowing low drop-out operation. This also improves inductor current slew rate during transients. An additional peak current comparator is needed to limit current during On-Time, as the classic valley limitation is not enough.","PeriodicalId":6689,"journal":{"name":"2020 AEIT International Annual Conference (AEIT)","volume":"467 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Low drop-out COT buck converter without maximum duty cycle limitation due to minimum Off-Time\",\"authors\":\"M. Gobbi, Adalberto Mariani\",\"doi\":\"10.23919/AEIT50178.2020.9241198\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Constant On-Time (COT) buck DC-DC converters are widely used due to high responsiveness, reliability and simple design. However, maximum duty cycle and inductor charging slew rate are limited by minimum Off-Time [1]. The proposed solution overcomes these limitations, providing a wide output range converter with enhanced transient response. A constant on time buck converter, where On-Time is extended beyond the internal timer if output voltage is lower than reference, is proposed. As a benefit, there is no limitation to maximum duty cycle due to minimum off time, just allowing low drop-out operation. This also improves inductor current slew rate during transients. An additional peak current comparator is needed to limit current during On-Time, as the classic valley limitation is not enough.\",\"PeriodicalId\":6689,\"journal\":{\"name\":\"2020 AEIT International Annual Conference (AEIT)\",\"volume\":\"467 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 AEIT International Annual Conference (AEIT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/AEIT50178.2020.9241198\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 AEIT International Annual Conference (AEIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/AEIT50178.2020.9241198","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

恒定导通(COT)降压型DC-DC变换器因其高响应性、高可靠性和简单的设计而得到广泛应用。然而,最大占空比和电感充电压转率受到最小Off-Time的限制[1]。所提出的解决方案克服了这些限制,提供了具有增强瞬态响应的宽输出范围变换器。提出了一种恒定导通时间buck变换器,当输出电压低于基准电压时,导通时间将扩展到内部定时器之外。作为一个好处,没有限制最大占空比由于最小的关闭时间,只是允许低drop-out操作。这也提高了电感电流在瞬态期间的转换率。需要一个额外的峰值电流比较器来限制On-Time期间的电流,因为经典的谷限制是不够的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Low drop-out COT buck converter without maximum duty cycle limitation due to minimum Off-Time
Constant On-Time (COT) buck DC-DC converters are widely used due to high responsiveness, reliability and simple design. However, maximum duty cycle and inductor charging slew rate are limited by minimum Off-Time [1]. The proposed solution overcomes these limitations, providing a wide output range converter with enhanced transient response. A constant on time buck converter, where On-Time is extended beyond the internal timer if output voltage is lower than reference, is proposed. As a benefit, there is no limitation to maximum duty cycle due to minimum off time, just allowing low drop-out operation. This also improves inductor current slew rate during transients. An additional peak current comparator is needed to limit current during On-Time, as the classic valley limitation is not enough.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信