心血管植入式电子设备相关感染的发生率、管理模式和结果——基于登记的回顾性分析

P. Goel, P. Rajput, A. Sahu, Roopali Khanna, N. Garg, S. Tewari, Sudeep Kumar, A. Kapoor
{"title":"心血管植入式电子设备相关感染的发生率、管理模式和结果——基于登记的回顾性分析","authors":"P. Goel, P. Rajput, A. Sahu, Roopali Khanna, N. Garg, S. Tewari, Sudeep Kumar, A. Kapoor","doi":"10.4103/jicc.jicc_55_21","DOIUrl":null,"url":null,"abstract":"Introduction: Cardiovascular implantable electronic device (CIED) infection contributes to a significant clinical and financial burden. We sought to assess CIED postimplant infection rates and the effect of different treatment modalities on reinfection over a long-term follow-up. Methods: We retrospectively analyzed CIED recipients presenting with complications during 2010–2019 at our center. Data related to the different management modalities used as per the discretion of treating physician, were collected and patients were followed up telephonically. Results: A total of 3394 patients underwent CIED implantation of which 122 (3.5%) patients developing complications were included in the study. Mean age of the patients was 66.4 ± 12.5 years. Single-chamber ventricular pacing (VVI), dual-chamber (DDD) pacing, and biventricular pacing were seen in 68 (56.2%), 51 (41%), and 3 (2.8%) patients, respectively. CIED infection was seen in 61 patients (1.8%). Strategies used for CIED infection management included: new device implantation on contralateral side (n = 34; 55.7%), old device repositioning on same side (n = 14; 22.8%), antibiotic therapy alone (n = 5; 8.5%), resterilized device implantation on contralateral side (n = 3; 4.9%), epicardial lead placement (n = 3; 4.9%), and permanent device removal (n = 2; 3.3%). The CIED reinfection rates for the above strategies were 2.9%, 71.4%, 80%, 100%, 0% and 0%, respectively. Conclusion: Multiple strategies are being used in real-world practice for the management of CIED infection. Previously advocated strategy of reimplanting resterilized CIED is associated with high recurrence rates. The best practice still remains to implant a new device on the contralateral side post extraction of infected hardware.","PeriodicalId":100789,"journal":{"name":"Journal of Indian College of Cardiology","volume":"7 1","pages":"156 - 161"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Incidence, management patterns, and outcomes of cardiovascular implantable electronic device-related infection – A retrospective registry-based analysis\",\"authors\":\"P. Goel, P. Rajput, A. Sahu, Roopali Khanna, N. Garg, S. Tewari, Sudeep Kumar, A. Kapoor\",\"doi\":\"10.4103/jicc.jicc_55_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Cardiovascular implantable electronic device (CIED) infection contributes to a significant clinical and financial burden. We sought to assess CIED postimplant infection rates and the effect of different treatment modalities on reinfection over a long-term follow-up. Methods: We retrospectively analyzed CIED recipients presenting with complications during 2010–2019 at our center. Data related to the different management modalities used as per the discretion of treating physician, were collected and patients were followed up telephonically. Results: A total of 3394 patients underwent CIED implantation of which 122 (3.5%) patients developing complications were included in the study. Mean age of the patients was 66.4 ± 12.5 years. Single-chamber ventricular pacing (VVI), dual-chamber (DDD) pacing, and biventricular pacing were seen in 68 (56.2%), 51 (41%), and 3 (2.8%) patients, respectively. CIED infection was seen in 61 patients (1.8%). Strategies used for CIED infection management included: new device implantation on contralateral side (n = 34; 55.7%), old device repositioning on same side (n = 14; 22.8%), antibiotic therapy alone (n = 5; 8.5%), resterilized device implantation on contralateral side (n = 3; 4.9%), epicardial lead placement (n = 3; 4.9%), and permanent device removal (n = 2; 3.3%). The CIED reinfection rates for the above strategies were 2.9%, 71.4%, 80%, 100%, 0% and 0%, respectively. Conclusion: Multiple strategies are being used in real-world practice for the management of CIED infection. Previously advocated strategy of reimplanting resterilized CIED is associated with high recurrence rates. The best practice still remains to implant a new device on the contralateral side post extraction of infected hardware.\",\"PeriodicalId\":100789,\"journal\":{\"name\":\"Journal of Indian College of Cardiology\",\"volume\":\"7 1\",\"pages\":\"156 - 161\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian College of Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jicc.jicc_55_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian College of Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jicc.jicc_55_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

心血管植入式电子设备(CIED)感染造成了严重的临床和经济负担。我们试图在长期随访中评估CIED移植后的感染率以及不同治疗方式对再感染的影响。方法:回顾性分析2010-2019年在本中心出现并发症的CIED受者。根据治疗医生的判断,收集了与不同管理模式相关的数据,并对患者进行了电话随访。结果:共3394例患者接受了CIED植入,其中122例(3.5%)患者出现了并发症。患者平均年龄66.4±12.5岁。单室起搏(VVI)、双室起搏(DDD)和双室起搏分别出现68例(56.2%)、51例(41%)和3例(2.8%)。61例(1.8%)发生CIED感染。CIED感染管理策略包括:对侧植入新器械(n = 34);55.7%),同侧旧器械复位(n = 14;22.8%),单独使用抗生素治疗(n = 5;8.5%),对侧再消毒器械植入(n = 3;4.9%)、心外膜置铅(n = 3;4.9%),永久装置移除(n = 2;3.3%)。上述策略的CIED再感染率分别为2.9%、71.4%、80%、100%、0%和0%。结论:在现实世界的实践中,多种策略被用于管理CIED感染。先前提倡的再植入术与高复发率有关。最好的做法仍然是在拔出受感染的硬体后在对侧植入新装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Incidence, management patterns, and outcomes of cardiovascular implantable electronic device-related infection – A retrospective registry-based analysis
Introduction: Cardiovascular implantable electronic device (CIED) infection contributes to a significant clinical and financial burden. We sought to assess CIED postimplant infection rates and the effect of different treatment modalities on reinfection over a long-term follow-up. Methods: We retrospectively analyzed CIED recipients presenting with complications during 2010–2019 at our center. Data related to the different management modalities used as per the discretion of treating physician, were collected and patients were followed up telephonically. Results: A total of 3394 patients underwent CIED implantation of which 122 (3.5%) patients developing complications were included in the study. Mean age of the patients was 66.4 ± 12.5 years. Single-chamber ventricular pacing (VVI), dual-chamber (DDD) pacing, and biventricular pacing were seen in 68 (56.2%), 51 (41%), and 3 (2.8%) patients, respectively. CIED infection was seen in 61 patients (1.8%). Strategies used for CIED infection management included: new device implantation on contralateral side (n = 34; 55.7%), old device repositioning on same side (n = 14; 22.8%), antibiotic therapy alone (n = 5; 8.5%), resterilized device implantation on contralateral side (n = 3; 4.9%), epicardial lead placement (n = 3; 4.9%), and permanent device removal (n = 2; 3.3%). The CIED reinfection rates for the above strategies were 2.9%, 71.4%, 80%, 100%, 0% and 0%, respectively. Conclusion: Multiple strategies are being used in real-world practice for the management of CIED infection. Previously advocated strategy of reimplanting resterilized CIED is associated with high recurrence rates. The best practice still remains to implant a new device on the contralateral side post extraction of infected hardware.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信