经导管主动脉瓣置入术多期超声心动图评价特点

G. Yemets, O. Telehuzova, G. Mankovsky, A. Maksymenko, Y. Marushko, A. Dovhaliuk, A. Sokol, I. Yemets
{"title":"经导管主动脉瓣置入术多期超声心动图评价特点","authors":"G. Yemets, O. Telehuzova, G. Mankovsky, A. Maksymenko, Y. Marushko, A. Dovhaliuk, A. Sokol, I. Yemets","doi":"10.31928/1608-635X-2021.1.4351","DOIUrl":null,"url":null,"abstract":"The aim – to systematize information on key features of echocardiographic evaluation of transcatheter aortic valve implantation (TAVI) procedure stages and their effectiveness in cardiac surgery, in patients with severe aortic valve stenosis.Materials and methods. We initiated a single-center clinical study to evaluate the XPand device and initial analysis of the primary results was performed. Patients met the inclusion criteria underwent a full range of examinations and TAVI procedures using the XPand device. The key parameters for echocardiographic examination in TAVI, which influence the formation of further procedure strategy, have been determined for the cardiac surgeon.Results and discussion. Based on the determined echocardiographic parameters, we obtained the primary outcomes of TAVI XPand in patients (n=7), the result of implantation was good. Minimal paravalvular insufficiency absence was found in 71.5 % of patients and minimal insufficiency in 14,5 %. In one patient to moderate insufficiency was observed. There was a statistically significant improvement in the ejection fraction (p<0.05) and a decrease in the mean gradient at the aortic valve (p<0.01).Conclusions. Echocardiographic parameters at all TAVI stages in patients over 75 years allow to control the implementation of the procedure and to improve the immediate post procedural outcome. The first experience of using the novel device for transcatheter implantation of the XPand aortic valve prosthesis confirms its effectiveness and safety in elderly patients with severe aortic stenosis.","PeriodicalId":23419,"journal":{"name":"Ukrainian Journal of Cardiology","volume":"2014 1","pages":"43-51"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Features of echocardiographic assessment on transcatheter aortic valve implantation multiple stages\",\"authors\":\"G. Yemets, O. Telehuzova, G. Mankovsky, A. Maksymenko, Y. Marushko, A. Dovhaliuk, A. Sokol, I. Yemets\",\"doi\":\"10.31928/1608-635X-2021.1.4351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim – to systematize information on key features of echocardiographic evaluation of transcatheter aortic valve implantation (TAVI) procedure stages and their effectiveness in cardiac surgery, in patients with severe aortic valve stenosis.Materials and methods. We initiated a single-center clinical study to evaluate the XPand device and initial analysis of the primary results was performed. Patients met the inclusion criteria underwent a full range of examinations and TAVI procedures using the XPand device. The key parameters for echocardiographic examination in TAVI, which influence the formation of further procedure strategy, have been determined for the cardiac surgeon.Results and discussion. Based on the determined echocardiographic parameters, we obtained the primary outcomes of TAVI XPand in patients (n=7), the result of implantation was good. Minimal paravalvular insufficiency absence was found in 71.5 % of patients and minimal insufficiency in 14,5 %. In one patient to moderate insufficiency was observed. There was a statistically significant improvement in the ejection fraction (p<0.05) and a decrease in the mean gradient at the aortic valve (p<0.01).Conclusions. Echocardiographic parameters at all TAVI stages in patients over 75 years allow to control the implementation of the procedure and to improve the immediate post procedural outcome. The first experience of using the novel device for transcatheter implantation of the XPand aortic valve prosthesis confirms its effectiveness and safety in elderly patients with severe aortic stenosis.\",\"PeriodicalId\":23419,\"journal\":{\"name\":\"Ukrainian Journal of Cardiology\",\"volume\":\"2014 1\",\"pages\":\"43-51\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ukrainian Journal of Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31928/1608-635X-2021.1.4351\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ukrainian Journal of Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31928/1608-635X-2021.1.4351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:对经导管主动脉瓣置入术(TAVI)阶段超声心动图评价的关键特征及其在心脏外科手术中严重主动脉瓣狭窄患者的有效性进行系统化的信息。材料和方法。我们启动了一项单中心临床研究来评估XPand装置,并对主要结果进行了初步分析。符合纳入标准的患者使用XPand设备进行了全面检查和TAVI手术。为心脏外科医生确定了超声心动图检查的关键参数,这些参数会影响TAVI进一步手术策略的形成。结果和讨论。根据确定的超声心动图参数,我们获得TAVI XPand患者(n=7)的主要结局,植入效果良好。71.5%的患者有轻微瓣旁功能不全,14.5%的患者有轻微瓣旁功能不全。1例患者观察到中度肾功能不全。两组患者的射血分数改善有统计学意义(p<0.05),主动脉瓣平均梯度降低有统计学意义(p<0.01)。75岁以上TAVI患者所有阶段的超声心动图参数可以控制手术的实施并改善手术后的即时结果。首次应用该新型装置经导管植入XPand主动脉瓣假体,证实了其在老年重度主动脉瓣狭窄患者中的有效性和安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Features of echocardiographic assessment on transcatheter aortic valve implantation multiple stages
The aim – to systematize information on key features of echocardiographic evaluation of transcatheter aortic valve implantation (TAVI) procedure stages and their effectiveness in cardiac surgery, in patients with severe aortic valve stenosis.Materials and methods. We initiated a single-center clinical study to evaluate the XPand device and initial analysis of the primary results was performed. Patients met the inclusion criteria underwent a full range of examinations and TAVI procedures using the XPand device. The key parameters for echocardiographic examination in TAVI, which influence the formation of further procedure strategy, have been determined for the cardiac surgeon.Results and discussion. Based on the determined echocardiographic parameters, we obtained the primary outcomes of TAVI XPand in patients (n=7), the result of implantation was good. Minimal paravalvular insufficiency absence was found in 71.5 % of patients and minimal insufficiency in 14,5 %. In one patient to moderate insufficiency was observed. There was a statistically significant improvement in the ejection fraction (p<0.05) and a decrease in the mean gradient at the aortic valve (p<0.01).Conclusions. Echocardiographic parameters at all TAVI stages in patients over 75 years allow to control the implementation of the procedure and to improve the immediate post procedural outcome. The first experience of using the novel device for transcatheter implantation of the XPand aortic valve prosthesis confirms its effectiveness and safety in elderly patients with severe aortic stenosis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信