高压陶瓷馈线中电压击穿放电事件的测量

E. Yamamoto, S. Shermer, A. Hutchinson
{"title":"高压陶瓷馈线中电压击穿放电事件的测量","authors":"E. Yamamoto, S. Shermer, A. Hutchinson","doi":"10.1109/NSS/MIC42677.2020.9507934","DOIUrl":null,"url":null,"abstract":"Ceramic insulated hermetic feedthroughs are used as signal and high-voltage conduits for sealed gamma radiation detectors with applications in oil and gas exploration. In configurations where signal and high-voltage are supplied via the same feedthrough, voltage breakdown of the gas filling the gap between the conducting wire and coaxial ceramic insulator may produce a charge pulse that is indistinguishable from a gamma detection pulse. This work describes a method to measure the discrete pulses generated by discharges across an air gap between a conducting wire and a coaxial ceramic insulator at 1600V and 150C ambient temperature. The data presented show results of measurements from discrete discharge events containing between ~0.5 pico-Coulombs and 200 pico-Coulombs of charge per event. Samples were tested that had undergone various operations including welding and soldering. Different cleaning operations were applied to some samples to determine whether discharges could be attributed to surface contamination. Measurements of samples where the ceramic insulator was manufactured using two different forming processes was also performed. This method is shown to provide a sensitive tool to screen hermetic components in radiation detectors used for oil and gas exploration.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"48 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of Discharge Events Due to Voltage Breakdown in High-Voltage Ceramic Feedthroughs\",\"authors\":\"E. Yamamoto, S. Shermer, A. Hutchinson\",\"doi\":\"10.1109/NSS/MIC42677.2020.9507934\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ceramic insulated hermetic feedthroughs are used as signal and high-voltage conduits for sealed gamma radiation detectors with applications in oil and gas exploration. In configurations where signal and high-voltage are supplied via the same feedthrough, voltage breakdown of the gas filling the gap between the conducting wire and coaxial ceramic insulator may produce a charge pulse that is indistinguishable from a gamma detection pulse. This work describes a method to measure the discrete pulses generated by discharges across an air gap between a conducting wire and a coaxial ceramic insulator at 1600V and 150C ambient temperature. The data presented show results of measurements from discrete discharge events containing between ~0.5 pico-Coulombs and 200 pico-Coulombs of charge per event. Samples were tested that had undergone various operations including welding and soldering. Different cleaning operations were applied to some samples to determine whether discharges could be attributed to surface contamination. Measurements of samples where the ceramic insulator was manufactured using two different forming processes was also performed. This method is shown to provide a sensitive tool to screen hermetic components in radiation detectors used for oil and gas exploration.\",\"PeriodicalId\":6760,\"journal\":{\"name\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"volume\":\"48 1\",\"pages\":\"1-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSS/MIC42677.2020.9507934\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9507934","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

陶瓷绝缘密封馈线作为信号和高压管道,用于密封伽马辐射探测器,在石油和天然气勘探中的应用。在信号和高压通过同一馈通提供的配置中,填充导线和同轴陶瓷绝缘体之间空隙的气体的电压击穿可能产生与伽马探测脉冲难以区分的电荷脉冲。这项工作描述了一种在1600V和150C环境温度下测量导线和同轴陶瓷绝缘体之间的气隙放电产生的离散脉冲的方法。所提供的数据显示了对离散放电事件的测量结果,每个事件的电荷在~0.5皮库仑到200皮库仑之间。测试的样品经过了各种操作,包括焊接和焊接。不同的清洗操作应用于一些样品,以确定排放是否可归因于表面污染。对陶瓷绝缘体采用两种不同成型工艺制造的样品进行了测量。该方法被证明为筛选用于石油和天然气勘探的辐射探测器中的密封元件提供了一种灵敏的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement of Discharge Events Due to Voltage Breakdown in High-Voltage Ceramic Feedthroughs
Ceramic insulated hermetic feedthroughs are used as signal and high-voltage conduits for sealed gamma radiation detectors with applications in oil and gas exploration. In configurations where signal and high-voltage are supplied via the same feedthrough, voltage breakdown of the gas filling the gap between the conducting wire and coaxial ceramic insulator may produce a charge pulse that is indistinguishable from a gamma detection pulse. This work describes a method to measure the discrete pulses generated by discharges across an air gap between a conducting wire and a coaxial ceramic insulator at 1600V and 150C ambient temperature. The data presented show results of measurements from discrete discharge events containing between ~0.5 pico-Coulombs and 200 pico-Coulombs of charge per event. Samples were tested that had undergone various operations including welding and soldering. Different cleaning operations were applied to some samples to determine whether discharges could be attributed to surface contamination. Measurements of samples where the ceramic insulator was manufactured using two different forming processes was also performed. This method is shown to provide a sensitive tool to screen hermetic components in radiation detectors used for oil and gas exploration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信