{"title":"联合剂型度洛西汀和甲钴胺同时测定的反相高效液相色谱方法建立及验证","authors":"K. Lavanya, Nutan N. Rao, V. Rao, K. Venkanna","doi":"10.7439/ijapa.v6i2.3834","DOIUrl":null,"url":null,"abstract":"A simple, precise, accurate, simultaneous stability indicating RP-HPLC method for the estimation of DLU (Duloxetin) and MCB (Methylcobalamine) in combined dosage form was developed using Intersil-C18 (4.6 x 250mm, 5m) in an Isocratic mode with mobile phase comprising of Phosphate buffer (pH 4.5) The flow rate was 1 mL/ min and effluent was monitored at 255.0 nm. The retention times were found to be 5.32 min for DLU and 3.59 min for MCB. The assay exhibited a linear dynamic range of 20- 120 g/mL for DLU and 10- 60 g/mL for MCB. The calibration curves were linear (r 2 = 0.999 for DLU and r 2 = 0.999 for MCB) over the entire linear range. Mean % recovery was found to be 99.68 % for DLU and 100.3 % for MCB with % RSD was NMT 2 for both estimations which fully agrees with system suitability which is in good agreement with labeled amount of formulation. The % RSD for Intra- Day & Inter-Day Precision was NMT than 2 for both the drugs. The developed method was validated as per ICH guidelines.","PeriodicalId":14317,"journal":{"name":"International Journal of Pharmaceutical Chemistry","volume":"40 1","pages":"09-15"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"RP-HPLC Method Development and Validation for Simultaneous Estimation of Duloxetin and Methylcobalamine in Combined Dosage Form\",\"authors\":\"K. Lavanya, Nutan N. Rao, V. Rao, K. Venkanna\",\"doi\":\"10.7439/ijapa.v6i2.3834\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple, precise, accurate, simultaneous stability indicating RP-HPLC method for the estimation of DLU (Duloxetin) and MCB (Methylcobalamine) in combined dosage form was developed using Intersil-C18 (4.6 x 250mm, 5m) in an Isocratic mode with mobile phase comprising of Phosphate buffer (pH 4.5) The flow rate was 1 mL/ min and effluent was monitored at 255.0 nm. The retention times were found to be 5.32 min for DLU and 3.59 min for MCB. The assay exhibited a linear dynamic range of 20- 120 g/mL for DLU and 10- 60 g/mL for MCB. The calibration curves were linear (r 2 = 0.999 for DLU and r 2 = 0.999 for MCB) over the entire linear range. Mean % recovery was found to be 99.68 % for DLU and 100.3 % for MCB with % RSD was NMT 2 for both estimations which fully agrees with system suitability which is in good agreement with labeled amount of formulation. The % RSD for Intra- Day & Inter-Day Precision was NMT than 2 for both the drugs. The developed method was validated as per ICH guidelines.\",\"PeriodicalId\":14317,\"journal\":{\"name\":\"International Journal of Pharmaceutical Chemistry\",\"volume\":\"40 1\",\"pages\":\"09-15\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Pharmaceutical Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7439/ijapa.v6i2.3834\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Pharmaceutical Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7439/ijapa.v6i2.3834","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
RP-HPLC Method Development and Validation for Simultaneous Estimation of Duloxetin and Methylcobalamine in Combined Dosage Form
A simple, precise, accurate, simultaneous stability indicating RP-HPLC method for the estimation of DLU (Duloxetin) and MCB (Methylcobalamine) in combined dosage form was developed using Intersil-C18 (4.6 x 250mm, 5m) in an Isocratic mode with mobile phase comprising of Phosphate buffer (pH 4.5) The flow rate was 1 mL/ min and effluent was monitored at 255.0 nm. The retention times were found to be 5.32 min for DLU and 3.59 min for MCB. The assay exhibited a linear dynamic range of 20- 120 g/mL for DLU and 10- 60 g/mL for MCB. The calibration curves were linear (r 2 = 0.999 for DLU and r 2 = 0.999 for MCB) over the entire linear range. Mean % recovery was found to be 99.68 % for DLU and 100.3 % for MCB with % RSD was NMT 2 for both estimations which fully agrees with system suitability which is in good agreement with labeled amount of formulation. The % RSD for Intra- Day & Inter-Day Precision was NMT than 2 for both the drugs. The developed method was validated as per ICH guidelines.