Sally Bishay, Malgorzata Michalowska-Suterska, A. Edling, Jason Battle
{"title":"采用标准化清洁工作流程及封闭式系统转移装置后配药临床场所危险药物表面污染评价","authors":"Sally Bishay, Malgorzata Michalowska-Suterska, A. Edling, Jason Battle","doi":"10.1515/pthp-2022-0004","DOIUrl":null,"url":null,"abstract":"Abstract Objectives The compounding and administration of hazardous drugs present a potential risk to healthcare worker and patient safety. This study sought to evaluate the HD surface contamination in multiple pharmacy and nursing areas that include standardized cleaning techniques and utilization of closed system transfer devices. Methods This study was conducted at six different areas in the pharmacy and nursing areas. Each area was assessed three times for five different HD’s surface contamination at an initial, 3 month, and 6 month follow up. Hazardous drug surface testing was performed for five most compounded HDs. A total of 90 individual samples were taken and analyzed during the study. Results A total of 30 samples were collected at three different timepoints for a total of 90 individual samples and analysis results. All 90 samples were negative (below the lower limit of detection; 0.01 ng/cm2), for their respective drug residue. Conclusions The method and design described in this evaluation may offer a way to determine if a facility’s current HD work practices and controls retain reduced HD surface contamination based upon published threshold values. Adoption and utilization of standardized work, including use of a closed system transfer device, and cleaning practices, described in this study, may present an option for facilities to retain reduced HD surface contamination, based upon previously determined threshold values.","PeriodicalId":19802,"journal":{"name":"Pharmaceutical Technology in Hospital Pharmacy","volume":"40 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the hazardous drug surface contamination in pharmacy compounding and administration clinical setting after adoption of standardized cleaning workflow and a closed system transfer device\",\"authors\":\"Sally Bishay, Malgorzata Michalowska-Suterska, A. Edling, Jason Battle\",\"doi\":\"10.1515/pthp-2022-0004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Objectives The compounding and administration of hazardous drugs present a potential risk to healthcare worker and patient safety. This study sought to evaluate the HD surface contamination in multiple pharmacy and nursing areas that include standardized cleaning techniques and utilization of closed system transfer devices. Methods This study was conducted at six different areas in the pharmacy and nursing areas. Each area was assessed three times for five different HD’s surface contamination at an initial, 3 month, and 6 month follow up. Hazardous drug surface testing was performed for five most compounded HDs. A total of 90 individual samples were taken and analyzed during the study. Results A total of 30 samples were collected at three different timepoints for a total of 90 individual samples and analysis results. All 90 samples were negative (below the lower limit of detection; 0.01 ng/cm2), for their respective drug residue. Conclusions The method and design described in this evaluation may offer a way to determine if a facility’s current HD work practices and controls retain reduced HD surface contamination based upon published threshold values. Adoption and utilization of standardized work, including use of a closed system transfer device, and cleaning practices, described in this study, may present an option for facilities to retain reduced HD surface contamination, based upon previously determined threshold values.\",\"PeriodicalId\":19802,\"journal\":{\"name\":\"Pharmaceutical Technology in Hospital Pharmacy\",\"volume\":\"40 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmaceutical Technology in Hospital Pharmacy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/pthp-2022-0004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutical Technology in Hospital Pharmacy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/pthp-2022-0004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of the hazardous drug surface contamination in pharmacy compounding and administration clinical setting after adoption of standardized cleaning workflow and a closed system transfer device
Abstract Objectives The compounding and administration of hazardous drugs present a potential risk to healthcare worker and patient safety. This study sought to evaluate the HD surface contamination in multiple pharmacy and nursing areas that include standardized cleaning techniques and utilization of closed system transfer devices. Methods This study was conducted at six different areas in the pharmacy and nursing areas. Each area was assessed three times for five different HD’s surface contamination at an initial, 3 month, and 6 month follow up. Hazardous drug surface testing was performed for five most compounded HDs. A total of 90 individual samples were taken and analyzed during the study. Results A total of 30 samples were collected at three different timepoints for a total of 90 individual samples and analysis results. All 90 samples were negative (below the lower limit of detection; 0.01 ng/cm2), for their respective drug residue. Conclusions The method and design described in this evaluation may offer a way to determine if a facility’s current HD work practices and controls retain reduced HD surface contamination based upon published threshold values. Adoption and utilization of standardized work, including use of a closed system transfer device, and cleaning practices, described in this study, may present an option for facilities to retain reduced HD surface contamination, based upon previously determined threshold values.