A. Rodríguez-Rodríguez, J. Egea-Guerrero, Á. Vilches-Arenas, Manuel Jesús Quintanilla-Vázquez, F. Murillo-Cabezas, M. Muñoz-Sanchez
{"title":"两种竞争性酶免疫测定试剂盒测定大鼠血浆尿紧张素- ii的比较","authors":"A. Rodríguez-Rodríguez, J. Egea-Guerrero, Á. Vilches-Arenas, Manuel Jesús Quintanilla-Vázquez, F. Murillo-Cabezas, M. Muñoz-Sanchez","doi":"10.1080/15321819.2016.1250772","DOIUrl":null,"url":null,"abstract":"ABSTRACT Changes in Urotensin-II (U-II) concentration, a potent vasoconstrictor peptide, have been detected in various pathologies, but it has been impossible to define a normality range. We aimed to analyze the concordance and interchangeability between two enzyme immunoassay methods developed by Phoenix Pharmaceuticals, Inc. to measure U-II plasma concentration in rats: ELISA and fluorescent EIA. Assays resulted positively correlated (r = 0.850; p < 0.01). There was a significant difference between assays values (p < 0.001). The analysis of agreement (Bland and Altman plot) stated that the mean of the differences was 2.055 (SD ± 0.588). Hence, we concluded that the two U-II assays were correlated but not interchangeable.","PeriodicalId":15987,"journal":{"name":"Journal of Immunoassay and Immunochemistry","volume":"47 1","pages":"247 - 256"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Comparison of two competitive enzyme immunoassay kits for quantification of plasma Urotensin-II in rats\",\"authors\":\"A. Rodríguez-Rodríguez, J. Egea-Guerrero, Á. Vilches-Arenas, Manuel Jesús Quintanilla-Vázquez, F. Murillo-Cabezas, M. Muñoz-Sanchez\",\"doi\":\"10.1080/15321819.2016.1250772\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Changes in Urotensin-II (U-II) concentration, a potent vasoconstrictor peptide, have been detected in various pathologies, but it has been impossible to define a normality range. We aimed to analyze the concordance and interchangeability between two enzyme immunoassay methods developed by Phoenix Pharmaceuticals, Inc. to measure U-II plasma concentration in rats: ELISA and fluorescent EIA. Assays resulted positively correlated (r = 0.850; p < 0.01). There was a significant difference between assays values (p < 0.001). The analysis of agreement (Bland and Altman plot) stated that the mean of the differences was 2.055 (SD ± 0.588). Hence, we concluded that the two U-II assays were correlated but not interchangeable.\",\"PeriodicalId\":15987,\"journal\":{\"name\":\"Journal of Immunoassay and Immunochemistry\",\"volume\":\"47 1\",\"pages\":\"247 - 256\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Immunoassay and Immunochemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/15321819.2016.1250772\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Immunoassay and Immunochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/15321819.2016.1250772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison of two competitive enzyme immunoassay kits for quantification of plasma Urotensin-II in rats
ABSTRACT Changes in Urotensin-II (U-II) concentration, a potent vasoconstrictor peptide, have been detected in various pathologies, but it has been impossible to define a normality range. We aimed to analyze the concordance and interchangeability between two enzyme immunoassay methods developed by Phoenix Pharmaceuticals, Inc. to measure U-II plasma concentration in rats: ELISA and fluorescent EIA. Assays resulted positively correlated (r = 0.850; p < 0.01). There was a significant difference between assays values (p < 0.001). The analysis of agreement (Bland and Altman plot) stated that the mean of the differences was 2.055 (SD ± 0.588). Hence, we concluded that the two U-II assays were correlated but not interchangeable.