{"title":"偏置平板检测器圆锥束CT的迭代重建","authors":"E. Hansis, J. Bredno, D. Sowards-Emmerd, L. Shao","doi":"10.1109/NSSMIC.2010.5874179","DOIUrl":null,"url":null,"abstract":"Circular cone-beam computed tomography (CBCT) with a tangentially offset flat-panel X-ray detector offers a large CT field-of-view (FoV) with a relatively small detector. It is used in practice, e.g., for target imaging in image-guided radiotherapy or for localization and attenuation correction in SPECT/CT imaging. The X-ray projections, acquired on a circular source trajectory, each cover roughly half the CT FoV; a central overlap region is imaged by all projections. Offset-detector CBCT reconstruction requires special algorithms. For large detector offsets, previously proposed filtered-backprojection methods can lead to shading artifacts, specifically left/right intensity imbalance. Here, we propose using iterative reconstruction for offset-detector CBCT. To handle the special acquisition geometry, known iterative reconstruction algorithms are modified in terms of axial truncation compensation, redundancy weighting, and algorithm initialization. An efficient implementation using a graphics processing unit (GPU) delivers clinically feasible reconstruction times. Results from patient and phantom studies are presented, showing a clear reduction of artifacts and improvement in image quality.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"4 1","pages":"2228-2231"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Iterative reconstruction for circular cone-beam CT with an offset flat-panel detector\",\"authors\":\"E. Hansis, J. Bredno, D. Sowards-Emmerd, L. Shao\",\"doi\":\"10.1109/NSSMIC.2010.5874179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Circular cone-beam computed tomography (CBCT) with a tangentially offset flat-panel X-ray detector offers a large CT field-of-view (FoV) with a relatively small detector. It is used in practice, e.g., for target imaging in image-guided radiotherapy or for localization and attenuation correction in SPECT/CT imaging. The X-ray projections, acquired on a circular source trajectory, each cover roughly half the CT FoV; a central overlap region is imaged by all projections. Offset-detector CBCT reconstruction requires special algorithms. For large detector offsets, previously proposed filtered-backprojection methods can lead to shading artifacts, specifically left/right intensity imbalance. Here, we propose using iterative reconstruction for offset-detector CBCT. To handle the special acquisition geometry, known iterative reconstruction algorithms are modified in terms of axial truncation compensation, redundancy weighting, and algorithm initialization. An efficient implementation using a graphics processing unit (GPU) delivers clinically feasible reconstruction times. Results from patient and phantom studies are presented, showing a clear reduction of artifacts and improvement in image quality.\",\"PeriodicalId\":13048,\"journal\":{\"name\":\"IEEE Nuclear Science Symposuim & Medical Imaging Conference\",\"volume\":\"4 1\",\"pages\":\"2228-2231\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposuim & Medical Imaging Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2010.5874179\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2010.5874179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Iterative reconstruction for circular cone-beam CT with an offset flat-panel detector
Circular cone-beam computed tomography (CBCT) with a tangentially offset flat-panel X-ray detector offers a large CT field-of-view (FoV) with a relatively small detector. It is used in practice, e.g., for target imaging in image-guided radiotherapy or for localization and attenuation correction in SPECT/CT imaging. The X-ray projections, acquired on a circular source trajectory, each cover roughly half the CT FoV; a central overlap region is imaged by all projections. Offset-detector CBCT reconstruction requires special algorithms. For large detector offsets, previously proposed filtered-backprojection methods can lead to shading artifacts, specifically left/right intensity imbalance. Here, we propose using iterative reconstruction for offset-detector CBCT. To handle the special acquisition geometry, known iterative reconstruction algorithms are modified in terms of axial truncation compensation, redundancy weighting, and algorithm initialization. An efficient implementation using a graphics processing unit (GPU) delivers clinically feasible reconstruction times. Results from patient and phantom studies are presented, showing a clear reduction of artifacts and improvement in image quality.